We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

GASCO Disposable Calibration Gas - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO Disposable Calibration Gas

The GASCO Calibration Gas: Nitrogen (MPN X02NI99CP1700L1) is a disposable calibration gas for all OEM gas detectors, featuring a CGA 600 connection and a gas mixture of Refrigerant R-22 250 ppm with a background gas…

SKU 3G-OTH-549320

Brand
GASCO
Item
Disposable Calibration Gas
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

GASCO
Manufacturer Part Number
X02NI99CP1700L1
Type
Disposable, +/-5% Accuracy, CHClF2, Calibration Gas, CGA 600
CGA Number
CGA 600
Gas Mixture
Refrigerant R-22 250 ppm
Reusability
Disposable
For Use With
All OEM Gas Detectors
Background Gas
Nitrogen

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Nitrogen (MPN X02NI99CP1700L1) is a disposable calibration gas for all OEM gas detectors, featuring a CGA 600 connection and a gas mixture of Refrigerant R-22 250 ppm with a background gas of nitrogen and +/-5% accuracy.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is GASCO calibration gas with R-22 used for?

This GASCO disposable calibration gas is used to verify and adjust the accuracy of all OEM gas detectors that sense refrigerant R-22. It contains 250 ppm R-22 in a nitrogen background with ±5% accuracy, ensuring reliable sensor response during routine safety checks.

What are the specifications of GASCO X02NI99CP1700L1?

The GASCO X02NI99CP1700L1 is a disposable calibration gas with a CGA 600 connection. It contains 250 ppm of refrigerant R-22 (CHClF2) in a nitrogen background, with ±5% accuracy. It is designed for use with all OEM gas detectors and is non-refillable.

Where to buy GASCO calibration gas in worldwide?

3G Electric supplies and delivers GASCO calibration gas worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to ensure your order arrives at your facility. Contact us for availability and lead time on this disposable R-22 calibration gas.

How to use GASCO disposable calibration gas for R-22 detectors?

Attach the CGA 600 regulator to the cylinder, then connect to your gas detector's inlet. Open the valve briefly to purge the line, then apply gas at the detector's specified flow rate. Follow the detector manufacturer's calibration procedure. Dispose of the cylinder responsibly after use.

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Disposable calibration gas cylinder containing 250 ppm Refrigerant R-134A (CH2FCF3) in nitrogen background gas, with ±5% accuracy and CGA 600 connection. Used to verify and calibrate portable gas detectors that sense refrigerant R-134A, compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing 250 ppm Refrigerant R-134A (CH2FCF3) in nitrogen background gas, with ±5% accuracy and CGA 600 connection. Used to verify and calibrate portable gas detectors that sense refrigerant R-134A, compatible with all OEM gas detectors
Disposable calibration gas mixture containing 1,500 ppm of Refrigerant R-134A (CH2FCF3) in a nitrogen background. Features +/-5% accuracy and a CGA 600 connection. Used to verify and adjust the accuracy of portable gas detectors in industrial environments
GASCO
Disposable calibration gas mixture containing 1,500 ppm of Refrigerant R-134A (CH2FCF3) in a nitrogen background. Features +/-5% accuracy and a CGA 600 connection. Used to verify and adjust the accuracy of portable gas detectors in industrial environments
Disposable calibration gas mixture containing 1% Ethylene with Nitrogen balance, supplied in a non-refillable cylinder with CGA 600 connection. Provides ±5% accuracy for verifying and adjusting the response of portable gas detectors used to monitor ethylene in industrial environments
GASCO
Disposable calibration gas mixture containing 1% Ethylene with Nitrogen balance, supplied in a non-refillable cylinder with CGA 600 connection. Provides ±5% accuracy for verifying and adjusting the response of portable gas detectors used to monitor ethylene in industrial environments
Disposable calibration gas cylinder containing Refrigerant R-22 at 300 ppm in an air background. Features ±5% accuracy and a CGA 600 connection. Used to verify and adjust the accuracy of portable gas detectors in HVAC and industrial safety applications
GASCO
Disposable calibration gas cylinder containing Refrigerant R-22 at 300 ppm in an air background. Features ±5% accuracy and a CGA 600 connection. Used to verify and adjust the accuracy of portable gas detectors in HVAC and industrial safety applications
Disposable calibration gas cylinder containing 16 ppm chlorine in nitrogen balance, with +/-5% accuracy. Used to verify and adjust the response of portable and fixed gas detectors to chlorine gas in industrial safety applications. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing 16 ppm chlorine in nitrogen balance, with +/-5% accuracy. Used to verify and adjust the response of portable and fixed gas detectors to chlorine gas in industrial safety applications. Compatible with all OEM gas detectors
Disposable calibration gas cylinder containing Refrigerant R-123 at 1,000 ppm in a nitrogen background. Provides +/-5% accuracy for verifying the performance of portable gas detectors used in refrigerant leak detection applications
GASCO
Disposable calibration gas cylinder containing Refrigerant R-123 at 1,000 ppm in a nitrogen background. Provides +/-5% accuracy for verifying the performance of portable gas detectors used in refrigerant leak detection applications

More from GASCO

View all GASCO parts
Disposable calibration gas mixture of 250 ppm chlorine in nitrogen background, with +/-5% accuracy. Used for verifying and calibrating portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas mixture of 250 ppm chlorine in nitrogen background, with +/-5% accuracy. Used for verifying and calibrating portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
Calibration gas mixture of 1.5% Methane (30% LEL) in air, with +/-5% accuracy. Supplied in a 105 L cylinder for use with all OEM portable gas detectors. Used to verify and adjust sensor response in gas detection equipment
GASCO
Calibration gas mixture of 1.5% Methane (30% LEL) in air, with +/-5% accuracy. Supplied in a 105 L cylinder for use with all OEM portable gas detectors. Used to verify and adjust sensor response in gas detection equipment
Calibration gas mixture of 2,000 ppm carbon monoxide in nitrogen background gas, supplied in a 105 L cylinder with +/-2% accuracy. Used to verify and adjust the response of portable gas detectors from all OEMs, providing a known reference concentration for sensor performance checks
GASCO
Calibration gas mixture of 2,000 ppm carbon monoxide in nitrogen background gas, supplied in a 105 L cylinder with +/-2% accuracy. Used to verify and adjust the response of portable gas detectors from all OEMs, providing a known reference concentration for sensor performance checks
Disposable calibration gas cylinder with Propane 275 ppm mixture in an air background, +/-5% accuracy, and CGA 600 fitting. Used for bump testing and calibration of portable gas detectors to verify sensor response
GASCO
Disposable calibration gas cylinder with Propane 275 ppm mixture in an air background, +/-5% accuracy, and CGA 600 fitting. Used for bump testing and calibration of portable gas detectors to verify sensor response
Disposable calibration gas mixture containing 95 ppm hydrogen sulfide in a nitrogen background. Provides +/-5% accuracy for verifying and adjusting hydrogen sulfide sensors in portable gas detectors. Suitable for use with all OEM gas detectors in industrial safety applications
GASCO
Disposable calibration gas mixture containing 95 ppm hydrogen sulfide in a nitrogen background. Provides +/-5% accuracy for verifying and adjusting hydrogen sulfide sensors in portable gas detectors. Suitable for use with all OEM gas detectors in industrial safety applications
This calibration gas contains 3% methane in a nitrogen background with +/-2% accuracy. It is used to verify and adjust the accuracy of portable gas detectors that sense methane. Supplied in a 105 L cylinder, it is compatible with all OEM gas detectors
GASCO
This calibration gas contains 3% methane in a nitrogen background with +/-2% accuracy. It is used to verify and adjust the accuracy of portable gas detectors that sense methane. Supplied in a 105 L cylinder, it is compatible with all OEM gas detectors
Disposable calibration gas cylinder containing a BAC 0.038% mixture of C2H6O in nitrogen background gas. Provides +/-5% accuracy for verifying and adjusting the response of portable gas detectors. Suitable for use with all OEM gas detectors in industrial safety applications
GASCO
Disposable calibration gas cylinder containing a BAC 0.038% mixture of C2H6O in nitrogen background gas. Provides +/-5% accuracy for verifying and adjusting the response of portable gas detectors. Suitable for use with all OEM gas detectors in industrial safety applications
Disposable calibration gas cylinder containing 0.6% pentane (42.9% LEL) in air, with ±5% accuracy. Fitted with a CGA 600 connection for use with portable gas detectors. Used to verify and adjust sensor response in industrial safety applications
GASCO
Disposable calibration gas cylinder containing 0.6% pentane (42.9% LEL) in air, with ±5% accuracy. Fitted with a CGA 600 connection for use with portable gas detectors. Used to verify and adjust sensor response in industrial safety applications