GASCO Calibration Gas: Nitrogen, 21% Oxygen, 105 L Cylinder - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO Calibration Gas: Nitrogen, 21% Oxygen, 105 L Cylinder

The GASCO Calibration Gas: Nitrogen is a +/-2% accuracy calibration gas for portable gas detectors, containing an Oxygen 21% mixture with a Nitrogen background gas. Supplied in a 105 L cylinder (MPN X02NI79CR150001)…

SKU 3G-OTH-550326

Brand
GASCO
Item
Calibration Gas: Nitrogen, 21% Oxygen, 105 L Cylinder
Part Number
X02NI79CR150001
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted. Invoices in PHP are paid online through the payment link on the invoice.

Technical Specifications

GASCO
Manufacturer Part Number
X02NI79CR150001
Type
+/-2% Accuracy, O2, Calibration Gas
Gas Mixture
Oxygen 21%
For Use With
All OEM Gas Detectors
Background Gas
Nitrogen
Cylinder Capacity
105 L

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Ask a question

Request a Quote

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Nitrogen is a +/-2% accuracy calibration gas for portable gas detectors, containing an Oxygen 21% mixture with a Nitrogen background gas. Supplied in a 105 L cylinder (MPN X02NI79CR150001), it is designed for use with all OEM gas detectors.

Supplied to the Philippines — compatible with 60 Hz installations. EXW Singapore — collect or forward from our Singapore office; onward freight to Manila, Quezon City, Cebu, customs and duties are the buyer's responsibility.

Frequently Asked Questions

What is GASCO calibration gas with oxygen 21% used for?

This GASCO calibration gas is used to verify and adjust the accuracy of portable gas detectors that sense oxygen. The 21% oxygen mixture in nitrogen background simulates normal air, allowing technicians to confirm that O2 sensors respond correctly across all OEM detector brands.

What are the specifications of GASCO calibration gas X02NI79CR150001?

This GASCO calibration gas has +/-2% accuracy, contains 21% oxygen balanced in nitrogen, and is supplied in a 105 L cylinder. It is designed for use with all OEM gas detectors. The manufacturer part number is X02NI79CR150001.

Where to buy GASCO calibration gas for portable gas detectors worldwide?

3G Electric supplies GASCO calibration gas worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact us to order the 105 L cylinder with 21% oxygen in nitrogen, part number X02NI79CR150001, for use with all OEM gas detectors.

How to use GASCO calibration gas with oxygen 21% for detector calibration?

Attach the GASCO cylinder regulator to the 105 L cylinder, connect to the detector's calibration port, and flow gas at the manufacturer-recommended rate. Allow the reading to stabilize, then adjust the detector to match the 21% oxygen value. Always follow the detector OEM's calibration procedure.

Not sure this is the right part? Photo-identify it→

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products and their technical documentation.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

More from GASCO

View all GASCO parts →
Disposable calibration gas mixture containing 5 ppm sulfur dioxide in nitrogen background gas, with ±5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response for SO2 detection in industrial safety applications
GASCO
Disposable calibration gas mixture containing 5 ppm sulfur dioxide in nitrogen background gas, with ±5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response for SO2 detection in industrial safety applications
Disposable calibration gas cylinder containing 5 ppm oxygen balanced with nitrogen. Designed for verifying and adjusting the accuracy of portable gas detectors used to monitor oxygen levels in confined spaces or low-oxygen environments. Provides +/-5% accuracy and is compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing 5 ppm oxygen balanced with nitrogen. Designed for verifying and adjusting the accuracy of portable gas detectors used to monitor oxygen levels in confined spaces or low-oxygen environments. Provides +/-5% accuracy and is compatible with all OEM gas detectors
This calibration gas contains 18% oxygen by volume in a nitrogen background, with +/-5% accuracy. It is used to verify the response of portable gas detectors that measure oxygen levels. Supplied in a 105-liter cylinder, it is compatible with all OEM gas detectors for routine calibration in industrial safety environments
GASCO
This calibration gas contains 18% oxygen by volume in a nitrogen background, with +/-5% accuracy. It is used to verify the response of portable gas detectors that measure oxygen levels. Supplied in a 105-liter cylinder, it is compatible with all OEM gas detectors for routine calibration in industrial safety environments
Disposable calibration gas cylinder containing methane at 30% LEL (1.5%) in a nitrogen background. Provides ±5% accuracy for verifying and adjusting portable gas detector response. Compatible with all OEM gas detectors for combustible gas monitoring in industrial safety applications
GASCO
Disposable calibration gas cylinder containing methane at 30% LEL (1.5%) in a nitrogen background. Provides ±5% accuracy for verifying and adjusting portable gas detector response. Compatible with all OEM gas detectors for combustible gas monitoring in industrial safety applications
Calibration gas mixture containing 250 ppm oxygen in nitrogen background, with +/-5% accuracy. Supplied in a 105 L cylinder. Used to calibrate portable gas detectors for oxygen monitoring in industrial safety applications
GASCO
Calibration gas mixture containing 250 ppm oxygen in nitrogen background, with +/-5% accuracy. Supplied in a 105 L cylinder. Used to calibrate portable gas detectors for oxygen monitoring in industrial safety applications
Disposable calibration gas cylinder containing 300 ppm carbon monoxide in an air background. Accuracy +/-5%. Designed for use with all OEM portable gas detectors to verify sensor response for CO, H2S, N2, and O2. Suitable for routine calibration in industrial safety applications
GASCO
Disposable calibration gas cylinder containing 300 ppm carbon monoxide in an air background. Accuracy +/-5%. Designed for use with all OEM portable gas detectors to verify sensor response for CO, H2S, N2, and O2. Suitable for routine calibration in industrial safety applications
Calibration gas cylinder containing Toluene (C7H8) at 10 ppm concentration in an air background. Accuracy is +/-5%. Cylinder capacity is 105 L. Used for verifying and calibrating portable gas detectors in industrial safety applications
GASCO
Calibration gas cylinder containing Toluene (C7H8) at 10 ppm concentration in an air background. Accuracy is +/-5%. Cylinder capacity is 105 L. Used for verifying and calibrating portable gas detectors in industrial safety applications
Disposable calibration gas cylinder containing 20.75% oxygen in a nitrogen background, with +/-5% accuracy. Used for routine verification and calibration of portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing 20.75% oxygen in a nitrogen background, with +/-5% accuracy. Used for routine verification and calibration of portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first