We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

GASCO Calibration Gas: Air, +/-2% Accuracy, C6H14, Calibration Gas, 105 L Cylinder Capacity - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO Calibration Gas: Air, +/-2% Accuracy, C6H14, Calibration Gas, 105 L Cylinder Capacity

The GASCO Calibration Gas: Air (MPN 105ES-289-5500) is a +/-2% accuracy calibration gas for portable gas detectors, containing a hexane mixture at 50% LEL (5,500 ppm) in a 105 L cylinder with air as the background…

SKU 3G-OTH-549663

Brand
GASCO
Item
Calibration Gas: Air, +/-2% Accuracy, C6H14, Calibration Gas, 105 L Cylinder Capacity
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GASCO
Manufacturer Part Number
105ES-289-5500
Type
+/-2% Accuracy, C6H14, Calibration Gas, Hexane
Gas Mixture
Hexane (50% LEL) 5,500 ppm
For Use With
All OEM Gas Detectors
Background Gas
Air
Cylinder Capacity
105 L
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Air (MPN 105ES-289-5500) is a +/-2% accuracy calibration gas for portable gas detectors, containing a hexane mixture at 50% LEL (5,500 ppm) in a 105 L cylinder with air as the background gas. Designed for use with all OEM gas detectors, it provides a verified hexane concentration for instrument calibration.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is GASCO calibration gas 105ES-289-5500 used for?

This GASCO calibration gas is used to verify and calibrate portable gas detectors that sense hexane. It contains a certified hexane mixture at 50% LEL (5,500 ppm) in a 105 L cylinder with air background, ensuring accurate sensor response for safety compliance.

What are the specifications of GASCO calibration gas 105ES-289-5500?

The GASCO 105ES-289-5500 calibration gas has +/-2% accuracy, contains hexane at 50% LEL (5,500 ppm) in a 105 L cylinder, with air as the background gas. It is designed for use with all OEM gas detectors and carries the GASCO brand.

Where to buy GASCO calibration gas 105ES-289-5500 worldwide?

3G Electric supplies the GASCO 105ES-289-5500 calibration gas to customers worldwide. We handle full logistics, customs clearance, and delivery, ensuring you receive the correct hexane calibration gas for your portable gas detectors, regardless of location.

How to use GASCO calibration gas 105ES-289-5500 for detector calibration?

Attach the regulator to the 105 L cylinder, connect to the gas detector's inlet, and flow the hexane mixture at the recommended rate. Allow the reading to stabilize, then adjust the detector to match the certified 5,500 ppm concentration. Always follow the detector manufacturer's instructions.

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from GASCO

View all GASCO parts
GASCO Calibration Gas: Air, +/-5% Accuracy, C5H12, Calibration Gas, 105 L Cylinder Capacity, Pentane (MPN 105ES-155-200). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Air; Brand: GASCO; Gas Mixture: Pentane 200 ppm.
GASCO
GASCO Calibration Gas: Air, +/-5% Accuracy, C5H12, Calibration Gas, 105 L Cylinder Capacity, Pentane (MPN 105ES-155-200). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Air; Brand: GASCO; Gas Mixture: Pentane 200 ppm.
GASCO Calibration Gas: Air, Disposable, +/-5% Accuracy, CH2Cl2, Calibration Gas, Calibration Gas (MPN X02AI99CP1000Y5). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Air; Brand: GASCO; Gas Mixture: Methylene Chloride 200 ppm; Reusability: Disposable.
GASCO
GASCO Calibration Gas: Air, Disposable, +/-5% Accuracy, CH2Cl2, Calibration Gas, Calibration Gas (MPN X02AI99CP1000Y5). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Air; Brand: GASCO; Gas Mixture: Methylene Chloride 200 ppm; Reusability: Disposable.
GASCO Calibration Gas: Air, Disposable, +/-5% Accuracy, NH3, Calibration Gas, 58 L Cylinder Capacity (MPN X02AI99CP5800F9). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Air; Brand: GASCO; Gas Mixture: Ammonia 400 ppm; Reusability: Disposable.
GASCO
GASCO Calibration Gas: Air, Disposable, +/-5% Accuracy, NH3, Calibration Gas, 58 L Cylinder Capacity (MPN X02AI99CP5800F9). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Air; Brand: GASCO; Gas Mixture: Ammonia 400 ppm; Reusability: Disposable.
GASCO Calibration Gas: Air, Disposable, +/-5% Accuracy, CO, Calibration Gas, 17 L Cylinder Capacity (MPN X02AI99CP1737Z4). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Air; Brand: GASCO; CGA Number: CGA 600; Gas Mixture: Carbon Monoxide 4,000 ppm; Reusability: Disposable.
GASCO
GASCO Calibration Gas: Air, Disposable, +/-5% Accuracy, CO, Calibration Gas, 17 L Cylinder Capacity (MPN X02AI99CP1737Z4). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Air; Brand: GASCO; CGA Number: CGA 600; Gas Mixture: Carbon Monoxide 4,000 ppm; Reusability: Disposable.
GASCO Calibration Gas: Air, Disposable, +/-5% Accuracy, C6H6/C7H8/C8H10, Calibration Gas, Cylinder (MPN X06AI99CP100000). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Air; Brand: GASCO; Gas Mixture: Toluene 10 ppm; Reusability: Disposable.
GASCO
GASCO Calibration Gas: Air, Disposable, +/-5% Accuracy, C6H6/C7H8/C8H10, Calibration Gas, Cylinder (MPN X06AI99CP100000). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Air; Brand: GASCO; Gas Mixture: Toluene 10 ppm; Reusability: Disposable.
GASCO Calibration Gas: Nitrogen, +/-2% Accuracy, O2, Calibration Gas, 105 L Cylinder Capacity (MPN X02NI96CR150005). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Nitrogen; Brand: GASCO; Gas Mixture: Oxygen 3.5%.
GASCO
GASCO Calibration Gas: Nitrogen, +/-2% Accuracy, O2, Calibration Gas, 105 L Cylinder Capacity (MPN X02NI96CR150005). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Nitrogen; Brand: GASCO; Gas Mixture: Oxygen 3.5%.
GASCO Calibration Gas: Nitrogen, Disposable, +/-5% Accuracy, CH4, Calibration Gas, Calibration Gas (MPN X02NI97CP106142). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Nitrogen; Brand: GASCO; Gas Mixture: Methane (50% LEL) 2.5%; Reusability: Disposable.
GASCO
GASCO Calibration Gas: Nitrogen, Disposable, +/-5% Accuracy, CH4, Calibration Gas, Calibration Gas (MPN X02NI97CP106142). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Nitrogen; Brand: GASCO; Gas Mixture: Methane (50% LEL) 2.5%; Reusability: Disposable.
GASCO Calibration Gas: Nitrogen, Disposable, +/-5% Accuracy, O2, Calibration Gas, Calibration Gas (MPN 103L-161-6.2). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Nitrogen; Brand: GASCO; Gas Mixture: Oxygen 6.2%; Reusability: Disposable.
GASCO
GASCO Calibration Gas: Nitrogen, Disposable, +/-5% Accuracy, O2, Calibration Gas, Calibration Gas (MPN 103L-161-6.2). Key specifications — For Use With: All OEM Gas Detectors; Background Gas: Nitrogen; Brand: GASCO; Gas Mixture: Oxygen 6.2%; Reusability: Disposable.