GASCO Calibration Gas: Air, Disposable, +/-5% Accuracy, C2H4, Calibration Gas
The GASCO Calibration Gas: Air is a disposable calibration gas for portable gas detectors, featuring a CGA 600 connection and ±5% accuracy. It contains an Ethylene mixture at 0.67% (25% LEL) with an air background…
SKU 3G-OTH-550982
Need installation or engineering help?
Ask a question
Product Description
The GASCO Calibration Gas: Air is a disposable calibration gas for portable gas detectors, featuring a CGA 600 connection and ±5% accuracy. It contains an Ethylene mixture at 0.67% (25% LEL) with an air background, designed for use with all OEM gas detectors.
Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.
Frequently Asked Questions
What is GASCO Calibration Gas 34LS-62A-0.67% used for?
This disposable calibration gas is used to verify and adjust the accuracy of portable gas detectors from all OEMs. It contains an Ethylene mixture at 0.67% (25% LEL) in an air background, with ±5% accuracy and a CGA 600 connection, ensuring reliable sensor response in industrial safety applications.
What are the specifications of GASCO Calibration Gas 34LS-62A-0.67%?
The GASCO 34LS-62A-0.67% is a disposable calibration gas with ±5% accuracy. It contains Ethylene at 0.67% (25% LEL) in an air background, uses a CGA 600 connection, and is compatible with all OEM gas detectors. The background gas is air, and the gas mixture is Ethylene (25% LEL) 0.67%.
Where to buy GASCO Calibration Gas 34LS-62A-0.67% worldwide?
3G Electric supplies GASCO calibration gas 34LS-62A-0.67% to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for availability and lead time on this disposable Ethylene calibration gas with CGA 600 connection.
How to use GASCO Calibration Gas 34LS-62A-0.67% for gas detector calibration?
Attach the CGA 600 regulator to the disposable cylinder, then connect to your gas detector's calibration port. Apply the Ethylene mixture at 0.67% (25% LEL) in air at the flow rate specified by the detector manufacturer. Allow the sensor to stabilize before reading the displayed value against the certified ±5% accuracy.