GASCO Calibration Gas: Nitrogen, Disposable, +/-5% Accuracy, C2H4, Calibration Gas
The GASCO Calibration Gas: Nitrogen is a disposable calibration gas for portable gas detectors, featuring an Ethylene 20 ppm mixture with +/-5% accuracy and a CGA 600 connection. Designed for use with all OEM gas…
SKU 3G-OTH-550990
Need installation or engineering help?
Ask a question
Product Description
The GASCO Calibration Gas: Nitrogen is a disposable calibration gas for portable gas detectors, featuring an Ethylene 20 ppm mixture with +/-5% accuracy and a CGA 600 connection. Designed for use with all OEM gas detectors, this nitrogen-background gas (MPN X02NI99CP1700A2) provides a reliable reference for verifying detector performance.
Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.
Frequently Asked Questions
What is GASCO calibration gas with ethylene 20 ppm used for?
This disposable GASCO calibration gas with a 20 ppm ethylene mixture in nitrogen is used to verify and calibrate portable gas detectors from all OEMs. It provides a known reference concentration to ensure accurate sensor response for ethylene detection in industrial safety applications.
What are the specifications of GASCO calibration gas X02NI99CP1700A2?
The GASCO calibration gas (MPN X02NI99CP1700A2) is a disposable cylinder with a CGA 600 connection, containing 20 ppm ethylene in nitrogen background gas. Accuracy is ±5%. It is designed for use with all OEM portable gas detectors for reliable calibration.
Where to buy GASCO calibration gas for gas detectors worldwide?
3G Electric supplies GASCO calibration gas (MPN X02NI99CP1700A2) to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us to order this disposable ethylene 20 ppm calibration gas for your gas detectors.
How to use GASCO disposable calibration gas for portable gas detectors?
Attach the GASCO cylinder with CGA 600 connection to the gas detector's calibration adapter. Open the valve to release the 20 ppm ethylene mixture in nitrogen at the specified flow rate. Follow the detector manufacturer's calibration procedure. Dispose of the cylinder after use as it is non-refillable.
GASCO Products
3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.