We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

GASCO 17L-18A-0.6 Isobutane Calibration Gas (33% LEL) 0.6% in Air - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO 17L-18A-0.6 Isobutane Calibration Gas (33% LEL) 0.6% in Air

The GASCO Calibration Gas: Air (MPN 17L-18A-0.6) is a disposable calibration gas for portable gas detectors, featuring a mixture of Isobutane (33% LEL) 0.6% with air as the background gas. It offers +/-5% accuracy…

SKU 3G-OTH-549669

Also listed as: 17L18A06 · 17L 18A 0 6 · 17L-18A-0-6

Brand
GASCO
Item
17L-18A-0.6 Isobutane Calibration Gas
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

GASCO
Manufacturer Part Number
17L-18A-0.6
Type
Disposable, +/-5% Accuracy, C4H10, Calibration Gas, Calibration Gas
CGA Number
CGA 600
Gas Mixture
Isobutane (33% LEL) 0.6%
Reusability
Disposable
For Use With
All OEM Gas Detectors
Background Gas
Air

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Air (MPN 17L-18A-0.6) is a disposable calibration gas for portable gas detectors, featuring a mixture of Isobutane (33% LEL) 0.6% with air as the background gas. It offers +/-5% accuracy, uses a CGA 600 connection, and is compatible with all OEM gas detectors.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is GASCO calibration gas 17L-18A-0.6 used for?

This disposable calibration gas is used to verify and adjust the accuracy of portable gas detectors across all OEM brands. It contains Isobutane (33% LEL) 0.6% in air, ensuring reliable sensor response for combustible gas monitoring in industrial safety applications.

What are the specifications of GASCO 17L-18A-0.6 calibration gas?

The GASCO 17L-18A-0.6 is a disposable calibration gas with +/-5% accuracy. It contains Isobutane (33% LEL) 0.6% in air background gas, uses a CGA 600 connection, and is compatible with all OEM gas detectors. The gas mixture is non-reusable.

Where to buy GASCO calibration gas 17L-18A-0.6 worldwide?

3G Electric supplies GASCO calibration gas 17L-18A-0.6 to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this disposable calibration gas.

How to use GASCO disposable calibration gas for gas detectors?

Attach the CGA 600 regulator to the cylinder, connect to the gas detector's inlet, and follow the detector's calibration menu. Apply the Isobutane mixture at the specified flow rate until readings stabilize. Dispose of the cylinder after single use per manufacturer guidelines.

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from GASCO

View all GASCO parts
This calibration gas contains 15 ppm Methylene Chloride (CH2Cl2) in air, with +/-5% accuracy. Supplied in a 105 L cylinder, it is used to verify and calibrate portable gas detectors in industrial safety applications
GASCO
This calibration gas contains 15 ppm Methylene Chloride (CH2Cl2) in air, with +/-5% accuracy. Supplied in a 105 L cylinder, it is used to verify and calibrate portable gas detectors in industrial safety applications
GASCO 105ES-75 is a +/-2% accuracy calibration gas mixture containing 75% hydrogen in a nitrogen background, supplied in a 105 L cylinder. It is used for verifying and calibrating portable gas detectors from all OEMs in industrial safety applications
GASCO
GASCO 105ES-75 is a +/-2% accuracy calibration gas mixture containing 75% hydrogen in a nitrogen background, supplied in a 105 L cylinder. It is used for verifying and calibrating portable gas detectors from all OEMs in industrial safety applications
Disposable calibration gas cylinder with a mixture of Carbon Monoxide 100 ppm in nitrogen background gas, accuracy +/-5%. Used to verify and calibrate portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder with a mixture of Carbon Monoxide 100 ppm in nitrogen background gas, accuracy +/-5%. Used to verify and calibrate portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
Disposable calibration gas cylinder containing a mixture of 50 ppm carbon monoxide in nitrogen, with methane and oxygen components. Features +/-5% accuracy and a CGA 600 connection. Used for verifying and calibrating portable gas detectors in industrial safety applications such as confined-space entry and plant maintenance
GASCO
Disposable calibration gas cylinder containing a mixture of 50 ppm carbon monoxide in nitrogen, with methane and oxygen components. Features +/-5% accuracy and a CGA 600 connection. Used for verifying and calibrating portable gas detectors in industrial safety applications such as confined-space entry and plant maintenance
Disposable calibration gas mixture of 1,000 ppm hydrogen chloride in nitrogen background gas. Accuracy ±5%. Designed for use with all OEM portable gas detectors to verify sensor response and ensure accurate readings in applications where HCl detection is required
GASCO
Disposable calibration gas mixture of 1,000 ppm hydrogen chloride in nitrogen background gas. Accuracy ±5%. Designed for use with all OEM portable gas detectors to verify sensor response and ensure accurate readings in applications where HCl detection is required
Calibration gas mixture containing propane at 1.05% (50% LEL) in nitrogen background, with +/-5% accuracy. Supplied in a 105-liter cylinder for use with portable gas detectors to verify combustible gas sensor performance
GASCO
Calibration gas mixture containing propane at 1.05% (50% LEL) in nitrogen background, with +/-5% accuracy. Supplied in a 105-liter cylinder for use with portable gas detectors to verify combustible gas sensor performance
Disposable calibration gas mixture containing 54 ppm hydrogen sulfide in nitrogen background, with ±5% accuracy. Designed for use with all OEM gas detectors to verify sensor response and calibration in industrial safety monitoring applications
GASCO
Disposable calibration gas mixture containing 54 ppm hydrogen sulfide in nitrogen background, with ±5% accuracy. Designed for use with all OEM gas detectors to verify sensor response and calibration in industrial safety monitoring applications
Disposable calibration gas cylinder containing 16 ppm hydrogen sulfide in a nitrogen background, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response and ensure accurate readings
GASCO
Disposable calibration gas cylinder containing 16 ppm hydrogen sulfide in a nitrogen background, with +/-5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response and ensure accurate readings