We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

3G Electric
GASCO 105ES-507 Calibration Gas, Heptane 1,000 ppm in Air, 105 L Cylinder - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO 105ES-507 Calibration Gas, Heptane 1,000 ppm in Air, 105 L Cylinder

The GASCO Calibration Gas: Air (MPN 105ES-507) is a +/-2% accuracy calibration gas with a heptane 1,000 ppm mixture in a background of air, supplied in a 105 L cylinder. Designed for use with all OEM gas detectors…

SKU 3G-OTH-550767

Also listed as: 105ES507 · 105ES 507

Brand
GASCO
Item
105ES-507 Calibration Gas, Heptane 1,000 ppm in Air, 105 L Cylinder
Part Number
105ES-507
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

GASCO
Manufacturer Part Number
105ES-507
Type
+/-2% Accuracy, C4H10/N2, Calibration Gas
Gas Mixture
Heptane 1,000 ppm
For Use With
All OEM Gas Detectors
Background Gas
Air
Cylinder Capacity
105 L

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Air (MPN 105ES-507) is a +/-2% accuracy calibration gas with a heptane 1,000 ppm mixture in a background of air, supplied in a 105 L cylinder. Designed for use with all OEM gas detectors, it provides a verified reference for portable gas detector calibration across industrial safety applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is GASCO calibration gas 105ES-507 used for?

GASCO calibration gas 105ES-507 is used to verify and calibrate portable gas detectors across industrial safety applications. Its heptane 1,000 ppm mixture in air provides a known reference to ensure detector accuracy for combustible gas monitoring in refineries, chemical plants, and confined spaces.

What are the specifications of GASCO 105ES-507 calibration gas?

The GASCO 105ES-507 calibration gas has +/-2% accuracy, a heptane 1,000 ppm mixture in a background of air, and a 105 L cylinder capacity. It is designed for use with all OEM gas detectors and carries the manufacturer part number 105ES-507.

Where to buy GASCO calibration gas 105ES-507 worldwide?

3G Electric supplies GASCO calibration gas 105ES-507 to customers worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this heptane 1,000 ppm calibration gas for portable gas detectors.

How to use GASCO 105ES-507 calibration gas for detector calibration?

Attach the regulator to the GASCO 105ES-507 cylinder, connect to the gas detector's inlet, and flow the heptane 1,000 ppm mixture at the detector's specified rate. Allow readings to stabilize, then adjust the detector to match the certified concentration. Always follow the detector manufacturer's calibration procedure.

Not sure this is the right part? Photo-identify it

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from GASCO

View all GASCO parts
Disposable calibration gas cylinder containing pentane at 0.3% concentration (21.4% LEL) in air background. Accuracy ±5%. Used for verifying and adjusting the response of portable gas detectors in industrial safety applications such as combustible gas monitoring
GASCO
Disposable calibration gas cylinder containing pentane at 0.3% concentration (21.4% LEL) in air background. Accuracy ±5%. Used for verifying and adjusting the response of portable gas detectors in industrial safety applications such as combustible gas monitoring
Disposable calibration gas cylinder containing 6 ppm sulfur dioxide in air, with ±5% accuracy and 58 L capacity. Used to verify and adjust the accuracy of portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing 6 ppm sulfur dioxide in air, with ±5% accuracy and 58 L capacity. Used to verify and adjust the accuracy of portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
Disposable calibration gas cylinder containing 3000 ppm hydrogen in air background gas. Accuracy ±5%. 103 L capacity. For use with portable gas detectors to verify sensor response and adjust readings
GASCO
Disposable calibration gas cylinder containing 3000 ppm hydrogen in air background gas. Accuracy ±5%. 103 L capacity. For use with portable gas detectors to verify sensor response and adjust readings
Disposable calibration gas cylinder containing 90 ppm methane in nitrogen with ±5% accuracy. Designed for use with portable gas detectors from all OEMs. Fitted with a CGA 600 connection
GASCO
Disposable calibration gas cylinder containing 90 ppm methane in nitrogen with ±5% accuracy. Designed for use with portable gas detectors from all OEMs. Fitted with a CGA 600 connection
Calibration gas mixture of 225 ppm carbon monoxide in nitrogen, supplied in a 105 L cylinder with ±2% accuracy. Used for calibrating portable gas detectors from all OEM manufacturers to verify sensor response to carbon monoxide
GASCO
Calibration gas mixture of 225 ppm carbon monoxide in nitrogen, supplied in a 105 L cylinder with ±2% accuracy. Used for calibrating portable gas detectors from all OEM manufacturers to verify sensor response to carbon monoxide
Calibration gas mixture containing 515 ppm carbon monoxide in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response to CO hazards
GASCO
Calibration gas mixture containing 515 ppm carbon monoxide in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response to CO hazards
Calibration gas mixture containing 20.5% oxygen balanced with nitrogen, certified to ±2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response. Suitable for routine calibration in industrial safety applications
GASCO
Calibration gas mixture containing 20.5% oxygen balanced with nitrogen, certified to ±2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response. Suitable for routine calibration in industrial safety applications
Calibration gas mixture containing 19% oxygen with nitrogen balance, supplied in a 105-liter cylinder. Certified to ±2% accuracy for use with portable gas detectors from all OEMs. Used to verify and adjust detector response in industrial safety applications
GASCO
Calibration gas mixture containing 19% oxygen with nitrogen balance, supplied in a 105-liter cylinder. Certified to ±2% accuracy for use with portable gas detectors from all OEMs. Used to verify and adjust detector response in industrial safety applications

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first