We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR GAS XP 80/M CE-LX4 is a two-stage gas burner for industrial heating applications, delivering 130–850 kW thermal power with low-NOx fuel capability. Operates at 79–82 dB with IP 40 protection, suitable for…

SKU 3G-FBR-00421

Also listed as: 00241341 · 002413 41 · 002413-41

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
50 kg
stage
2 stages sliding or modulating
fuel type
Gas low nox
nozzle mm
250
fan motor w
1.5
power kw max
850
power kw min
130
ip protection
IP 40
noisiness dba
79-82
gas consumption
12.8/40.8-85.3
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
3.1
thermal power mcal h
110/350-731
nominal electric power w
1.7
max combustion air temp c
60

Datasheet Content

GAS XP80/MCE GAS BURNERS TWO STAGES 073067_B_gb PROGRESSIVE OR MODULATING GAS XP80/MCE Burners for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. Composed by: die-cast aluminum body, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for operations of setting and maintenance. The burner is mounted on supports and tierods for burner extraction this permits retreat to disassemble and check the flame tube and the combustion head. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train complete of: working valve with flow adjustment, safety valve, minimum gas pressure switch and gas filter. Complete of flange and gasket for installation on generator. Fig. 1 GAS XP80/MCE GAS XP80/MCE GAS XP80/MCE GAS BURNERS TWO STAGES 073067_B_gb PROGRESSIVE OR MODULATING TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS XP80/MCE MODEL GAS XP80/MCE Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 110/350-731 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 128/407-850 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 12.8/40.8-85.3 Gas flow G25 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 14.9/47.5-99.1 Gas flow G25.3 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 14.6/46.4-97 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 5/15.8-33 Fuel: NATURAL GAS (second family, G20, G25, G25.3) - L.P.G. (third family, G31) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 94/53 Min. pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 24/24 Min. pressure gas train D2"-S NATURAL GAS/L.P.G. ** [mbar] 21/23 Min. pressure gas train DN65-FS65 NATURAL GAS/L.P.G. ** [mbar] 15/21 Min. pressure gas train DN80-FS80 NATURAL GAS/L.P.G. ** [mbar] - Maximum pressure at the entry of valves (D 1"1/4 - 1"1/2 - 2") [mbar] 360 Maximum pressure at the entry of valves (DN65 - DN80) [mbar] 500 Nominal electric power [kW] 1.7 Fan motor [kW] 1.5 Nominal motor current absorption [A] 3.1 Nominal auxiliary absorption [A] 0.7 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 NOx Class, NATURAL GAS (second family) 1 NOx Class, L.P.G. (third family) 2 Noisiness *** min. - max. [dB(A)] 79-82 Burner weight **** [kg] 51 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - Control method class 3 - The measured sound pressure tolerance can be assumed to be ± 1 [dB (A)]). **** For burner with long head add 2 kg to the weight. GAS XP80/MCE GAS XP80/MCE GAS BURNERS TWO STAGES 073067_B_gb PROGRESSIVE OR MODULATING [mbar] 14 GAS XP80/M CE 12 10 8 6 4 2 0 0 100 200 300 400 500 600 700 800 900 1000 [kW] Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. GAS XP80/MCE GAS XP80/MCE GAS BURNERS TWO STAGES 073067_B_gb PROGRESSIVE OR MODULATING DIMENSIONS [MM] Fig. 3 Dimensions GAS TRAIN A B C D1"1/4-S 520 345* 462 D1"1/2-S 541 361 462 D2"-S 541 361 462 DN65-FS65 663 430 556 * Includes length of 66 mm due to adapter code 057020 ** Overall dimension with the burner out in position of maintenance. TC - TL: Please see chapter "Flame tube length" GAS XP80/MCE GAS XP80/MCE GAS BURNERS TWO STAGES 073067_B_gb PROGRESSIVE OR MODULATING BOILER PLATE The dimensions of the boiler plate must be as indicated in the drawing. * Suggested dimension of connection between burner and generator. MODEL L min L* L max M N min N max GAS XP80/MCE mm 185 185 250 M12 310 365 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. FLAME TUBE LENGTH TC mm 250 TL mm 385 ** ** For different flame lengths, please contact our Technical-Sales Department. GAS XP80/MCE GAS XP80/MCE GAS BURNERS TWO STAGES 073067_B_gb PROGRESSIVE OR MODULATING BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 1 V V Fig. 4 Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). GAS XP80/MCE…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS XP 80/M CE-LX4 is a two-stage gas burner for industrial heating applications, delivering 130–850 kW thermal power with low-NOx fuel capability. Operates at 79–82 dB with IP 40 protection, suitable for modulating or progressive hi-low flame combustion systems.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR GAS XP 80/M CE-LX4 gas burner in the Philippines?

3G Electric Philippines is your sourcing partner for the FBR GAS XP 80/M CE-LX4. We deliver to Manila, Quezon City, and across the Philippines. We handle Bureau of Customs documentation, logistics, and PHP invoicing. Contact us for lead time and pricing.

What is the lead time for the FBR GAS XP 80/M CE-LX4?

Lead time on request. The FBR GAS XP 80/M CE-LX4 is available to order. 3G Electric manages sourcing and delivery to Philippines with full customs support. Email or call for your specific schedule.

What are the power and emissions specifications of the FBR GAS XP 80/M CE-LX4?

The FBR GAS XP 80/M CE-LX4 delivers 130–850 kW thermal power with two-stage progressive or modulating combustion. It is low-NOx Class 4 (NOx < 60 mg/kWh), IP 40 protected, and operates at 79–82 dB. Weight is 50 kg.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS XP 80/2 CE-LX4 TL Cl. 4 | Variant: variant_1 | Subgroup: Burner
FBR
GAS XP 80/2 CE-LX4 TL Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS XP 80/M CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 80/M CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 80/2 CE-LX4 TC Cl. 4 | Variant: variant_1 | Subgroup: Burner
FBR
GAS XP 80/2 CE-LX4 TC Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS XP 80/2 CE-LX4 TL Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
GAS XP 80/2 CE-LX4 TL Cl. 4 | Variant: GPL | Subgroup: Burner
GAS XP 80/2 CE-LX4 TC Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
GAS XP 80/2 CE-LX4 TC Cl. 4 | Variant: GPL | Subgroup: Burner
GAS XP 80/M CE-LX4 TL Cl. 4 | Variant: metano | Subgroup: Burner
FBR
GAS XP 80/M CE-LX4 TL Cl. 4 | Variant: metano | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL