We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

The FBR GAS XP 60 CE-LX TC EVO Cl. 4 is a single-stage gas burner delivering 200–542 kcal/h thermal power, with a 250 mm nozzle and gas consumption of 23.3–63.3 m³/h. It suits industrial heating and combustion…

SKU 3G-FBR-00525

Also listed as: 00277841 · 002778 41 · 002778-41

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
stage
Single stage
fuel type
Gas
nozzle mm
250
power kw max
630
power kw min
232
power kcal max
542
power kcal min
200
gas consumption
23.3-63.3
electrical supply
3
thermal power mcal h
200-542

Datasheet Content

GAS BURNERS AT SINGLE STAGE SK071010_2_B GAS฀BURNERS฀AT฀SINGLE฀STAGE GAS฀XP60CE฀EVO Burners฀for฀gas฀at฀single฀stage. They฀are฀composed฀by:฀fan฀at฀high฀pressurisation฀at฀reverse฀blades฀and฀combustion฀head฀with฀adjustment฀at฀high฀ efficiency฀and฀high฀flame฀stability. Compact฀overall฀dimensions฀and฀disposition฀rationalized฀of฀the฀components฀with฀accessibility฀facilitated฀for฀the฀ operations฀of฀setting฀and฀maintenance. Available฀in฀the฀versions฀METHANE฀(natural฀gas)฀or฀L.P.G.฀(to฀specify฀at฀the฀order)฀on฀demand฀specific฀versions฀for฀ town฀gas,฀coal฀gas฀or฀biogas. Gas฀train฀complete฀of฀single-stage฀working฀valve฀with฀flow฀adjustment,฀safety฀valve,฀minimum฀gas฀pressure฀switch฀and฀ gas฀filter. Complete฀of฀flange฀and฀gasket฀for฀installation฀on฀generator. Fig. 1 GAS฀XP60CE฀EVO GAS XP60CE EVO GAS BURNERS AT SINGLE STAGE SK071010_2_B TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS XP60CE EVO MODEL GAS XP60CE EVO Thermal฀power฀min.฀-฀max.฀* [Mcal/h] 200-542 Thermal฀power฀min.฀-฀max.฀* [kW] 232-630 Gas฀flow฀G20฀(NATURAL฀GAS)฀min.฀-฀max.฀* [Nm³/h] 23.3-63.3 Gas฀flow฀G31฀(L.P.G.)฀min.฀-฀max.฀* [Nm³/h] 9-24.5 Fuel:฀NATURAL฀GAS฀(second฀family)฀-฀L.P.G.฀(third฀family) Fuel฀category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) I3B/P,I3+,I3P,I3B,I3R Intermitted฀working฀operation฀(min.฀1฀stop฀every฀24฀hours)฀single฀stage Environmental฀conditions฀operation฀/฀storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max.฀temperature฀combustion฀air [°C] 60 Minimum฀pressure฀gas฀train฀D1"-S฀NATURAL฀GAS/L.P.G.฀** [mbar] 115.3 / 60 Minimum฀pressure฀gas฀train฀D1"1/4-S฀NATURAL฀GAS/L.P.G.฀** [mbar] 54.5 / 37.4 Minimum฀pressure฀gas฀train฀D1"1/2-S฀NATURAL฀GAS/L.P.G.฀** [mbar] 17.7 / 21.8 Maximum฀pressure฀at฀the฀entry฀of฀valves฀(Pe.฀max) [mbar] 360 Nominal฀electric฀power [W] 700 Fan฀motor [W] 550 Nominal฀powert฀absorption [A] 1.4 Nominal฀auxiliary฀absorption [A] 0.5 Power฀supply: 3~400V,1N~230V-50Hz Electric฀protection฀degree: IP 40 Noisiness฀***฀min.฀-฀max. [dB(A)] 69-72 Burner฀weight฀**** [kg] 29.5 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 - Metodo di controllo Classe 3 - La tolleranza sulla pressione sonora misurata può essere assunta pari a ± 1 [dB(A)]). **** For burner with long head add 1 kg to the weight. [mbar] 10 8 6 4 2 GAS XP60 0 -2 50 150 250 350 450 550 650 [kW] Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS XP60CE EVO GAS BURNERS AT SINGLE STAGE SK071010_2_B DIMENSIONS [MM] A 20 A H D R1 G RD TC-TL E B C R4 R2 F R3 Fig. 3 Dimensions GAS XP60CE EVO MODEL A B C D E F G H R1 R2 R3 R4 RD TC TL GAS฀XP60CE฀EVO฀-฀D1"-S 200 188 274 150 99 558 416 100 193 280 338 431 Rp 1 250 335 GAS฀XP60CE฀EVO฀-฀D1"1/4-S 200 188 274 150 99 558 416 100 193 280 338 431 Rp 1 1/4 250 335 GAS฀XP60CE฀EVO฀-฀D1"1/2-S 200 188 274 150 99 558 416 100 193 280 346 446 Rp 1 1/2 250 335 BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 4 Boiler plate MODEL L min L* L max M N min N* N max GAS฀XP60CE฀EVO mm 160 160 180 M10 205 205 226 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** GAS฀XP60CE฀EVO mm 250 335 ** For different flame lengths, please contact our Technical-Sales Department. GAS XP60CE EVO GAS BURNERS AT SINGLE STAGE SK071010_2_B BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 1 3 Fig. 5 Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp 3) GAS valve lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). GAS XP60CE EVO GAS BURNERS AT SINGLE STAGE SK071010_2_B PRODUCT SPECIFICATION SHORT DESCRIPTION Burners for gas at single stage. DETAILED SPECIFICATION Burner for gas at single stage; composed by: • Fan at high pressurisationat reverse blades ; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and steel flame disc; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Gas train with safety valve class A, adjustment 1st stage valve class A; • Ionisation probe for flame detection; • IP 40 electric protection level; • Easy extraction of combustion head without get off the burners by bolier. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive M.D.; • GAS 2016/426/UE Regulation; • Reference rules: EN676 (gas) – EN 746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Isomart gasket; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise฀protection; • Antivibration฀couplings; • Handle฀gas฀taps. The฀illustrations฀and฀data฀here฀shown฀are฀indicative.฀F.B.R.฀Bruciatori฀S.r.l.฀reserves฀the฀right฀to฀bring,฀without฀any฀obligation฀of฀warning,฀any฀changes฀that฀would฀be฀appropriate฀to฀the฀continuing฀development฀of฀their฀products. GAS XP60CE EVO

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR GAS XP 60 CE-LX TC EVO Cl. 4 is a single-stage gas burner delivering 200–542 kcal/h thermal power, with a 250 mm nozzle and gas consumption of 23.3–63.3 m³/h. It suits industrial heating and combustion applications requiring stable, efficient gas-fired thermal output.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I source the FBR GAS XP 60 burner in the Philippines?

3G Electric Philippines is an authorized distributor. We handle delivery to Manila and Quezon City, manage all Bureau of Customs documentation, and provide PHP invoicing. Lead time on request — contact our procurement team for availability and quotation.

What is the thermal power and gas consumption of this burner?

The FBR GAS XP 60 CE-LX TC EVO Cl. 4 delivers 200–542 kcal/h thermal power with gas consumption ranging from 23.3 to 63.3 m³/h. The 250 mm nozzle supports stable, efficient single-stage combustion for industrial heating applications.

Is this burner suitable for food processing or power generation applications?

Yes. The single-stage design with 3-phase electrical supply (three-phase) and stable 200–542 kcal/h output makes it suitable for industrial heating, food processing, and power generation. Confirm exact application requirements with our technical team before ordering.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS XP 60/M CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60/M CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 60/2 CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60/2 CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 60/2 CE-LX TL EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60/2 CE-LX TL EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 60 CE-LX TL EVO Cl. | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60 CE-LX TL EVO Cl. | Variant: variant_2 | Subgroup: Burner
GAS XP 60/M CE-LX TL EVO CL.4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60/M CE-LX TL EVO CL.4 | Variant: variant_2 | Subgroup: Burner
GAS XP 60/2 CE TC EVO | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60/2 CE TC EVO | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL