We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR GAS XP 60/2 CE TC EVO is a two-stage gas burner for industrial heating applications, delivering 116–630 kW thermal power with a 250 mm nozzle. Operating at 66–69 dBA and IP 40 protection, it suits medium to…

SKU 3G-FBR-00396

Also listed as: 00235941 · 002359 41 · 002359-41

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
16 kg
stage
2 stages
fuel type
Gas
nozzle mm
250
fan motor w
110
power kw max
630
power kw min
116
ip protection
IP 40
noisiness dba
66-69
gas consumption
11.6/23.3-63.3
electrical supply
3
power supply info
1N~230V
current absorption a
0.77
thermal power mcal h
100/200-542
nominal electric power w
200
max combustion air temp c
60

Datasheet Content

GAS BURNERS TWO STAGES GAS BURNERS TWO STAGES SK071011_2_B GAS XP60/2CE EVO Gas burners two stages with: aluminum body, fan at high pressurisation at reverse blades and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled, electrically linked and tested; complete of two stages working valve with flow adjustment, safety valve, minimum gas pressure switch and stabiliser filter of gas pressure. Complete of flange and gasket for installation on generator. Fig. 1 GAS XP60/2CE EVO GAS XP60/2CE EVO GAS BURNERS TWO STAGES SK071011_2_B TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS XP60/2CE EVO MODEL GAS XP60/2CE EVO Thermal฀power฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [Mcal/h] 100/200-542 Thermal฀power฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [kW] 116/232-630 Gas฀flow฀G20฀(NATURAL฀GAS)฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [Nm³/h] 11.6/23.3-63.3 Gas฀flow฀G31฀(L.P.G.)฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [Nm³/h] 4.5/9-24.5 Fuel:฀NATURAL฀GAS฀(second฀family)฀-฀L.P.G.฀(third฀family) Fuel฀category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) I3B/P,I3+,I3P,I3B,I3R Intermitted฀working฀operation฀(min.฀1฀stop฀every฀24฀hours)฀two฀stages Environmental฀conditions฀operation฀/฀storage: -15...+40°C / -20...+70°C, umidità rel. max. 80% Max.฀temperature฀combustion฀air [°C] 60 Minimum฀pressure฀gas฀train฀D1"-S฀NATURAL฀GAS/L.P.G.฀** [mbar] 115.3 / 60 Minimum฀pressure฀gas฀train฀D1"1/4-S฀NATURAL฀GAS/L.P.G.฀** [mbar] 54.5 / 37.4 Minimum฀pressure฀gas฀train฀D1"1/2-S฀NATURAL฀GAS/L.P.G.฀** [mbar] 17.7 / 21.8 Maximum฀pressure฀at฀the฀entry฀of฀valves฀(Pe.฀max) [mbar] 360 Nominal฀electric฀power [W] 700 Fan฀motor [W] 550 Nominal฀motor฀current฀absorption [A] 1.4 Nominal฀auxiliary฀absorption [A] 0.5 Power฀supply: 3~400V, 1N~230V - 50Hz Electric฀protection฀degree: IP 40 Noisiness฀***฀min.฀-฀max. [dB(A)] 69-72 Burner฀weight฀**** [kg] 30.5 *฀Reference฀conditions:฀Environment฀temperature฀20°C฀-฀Barometric฀pressure฀1013฀mbars฀-฀Altitude฀0฀metre฀(sea฀level). **฀Minimal฀feeding-gas฀pressure฀to฀the฀gas฀train฀to฀get฀the฀maximum฀power฀of฀the฀burner,฀considering฀counter-pressure฀in฀combustion฀chamber฀of฀ value฀0฀(zero). ***฀Measured฀sonorous฀pressure฀in฀the฀laboratory฀combustion,฀with฀functional฀burner฀on฀beta฀boiler฀to฀1฀metre฀of฀distance฀(UNI฀EN฀ISO฀3746฀- Control฀method฀Class฀3฀-฀The฀tolerance฀on฀the฀measured฀sound฀pressure฀can฀be฀assumed฀equal฀to฀±฀1฀[dB฀(A)]). ****฀For฀burner฀with฀long฀head฀add฀1฀kg฀to฀the฀weight. [mbar] 10 8 6 4 2 GAS XP60/2 0 -2 0 100 200 300 400 500 600 [kW] Fig. 2 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS XP60/2CE EVO GAS BURNERS TWO STAGES SK071011_2_B DIMENSIONS [MM] A 20 A H D R1 G TC-TL E RD B C R4 R2 F R3 Fig. 3 Dimensions GAS XP60/2CE EVO MODEL A B C D E F G H R1 R2 R3 R4 RD TC TL GAS฀XP60/2CE฀EVO฀-฀D1"-S 200 188 276 150 99 558 416 100 193 280 338 431 Rp 1 250 335 GAS฀XP60/2CE฀EVO฀-฀D1"1/4-S 200 188 276 150 99 558 416 100 193 280 338 431 Rp 1 1/4 250 335 GAS฀XP60/2CE฀EVO฀-฀D1"1/2-S 200 188 276 150 99 558 416 100 193 280 346 446 Rp 1 1/2 250 335 BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 4 Boiler plate MODEL L min L* L max M N min N* N max GAS฀XP60/2CE฀EVO mm 160 160 180 M10 205 205 226 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** GAS฀XP60/2CE฀EVO mm 250 335 ** For different flame lengths, please contact our Technical-Sales Department. GAS XP60/2CE EVO GAS BURNERS TWO STAGES SK071011_2_B BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 1 Fig. 5 Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). GAS XP60/2CE EVO GAS BURNERS TWO STAGES SK071011_2_B PRODUCT SPECIFICATION SHORT DESCRIPTION Gas burners two stages. DETAILED SPECIFICATION Gas burner two stages composed by: • Aluminum body; • Fan at high pressurisationwith reverse blades; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and steel flame disc; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Gas train with safety valve class A, adjustment two stages valve class A; • Optional valve proving system; • Ionisation probe for flame detection; • IP 40 electric protection level; • Servomotor for air shutter and for the consent of the 2nd stage gas valve; • Moving shutter with total closure when idle in order to reduce at the least energy losses related to boiler cooling down; • Easy extraction of combustion head without get off the burners by bolier. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive M.D.; • GAS 2016/426/UE Regulation; • Reference rules: EN676 (gas) – EN 746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Isomart gasket; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise฀protection; • Antivibration฀couplings; • Handle฀gas฀taps. The฀illustrations฀and฀data฀here฀shown฀are฀indicative.฀F.B.R.฀Bruciatori฀S.r.l.฀reserves฀the฀right฀to฀bring,฀without฀any฀obligation฀of฀warning,฀any฀changes฀that฀would฀be฀appropriate฀to฀the฀continuing฀development฀of฀their฀products. GAS XP60/2CE EVO

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS XP 60/2 CE TC EVO is a two-stage gas burner for industrial heating applications, delivering 116–630 kW thermal power with a 250 mm nozzle. Operating at 66–69 dBA and IP 40 protection, it suits medium to large-scale combustion systems requiring modulated output.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR GAS XP 60/2 CE TC EVO gas burner in the Philippines?

3G Electric Philippines supplies the FBR GAS XP 60/2 CE TC EVO gas burner with delivery to Manila and Quezon City. We handle all logistics, Bureau of Customs documentation, and PHP invoicing. Contact us for availability and lead time on request.

What is the lead time for the FBR GAS XP 60/2 CE TC EVO burner to the Philippines?

Lead time depends on stock status and shipping from origin. 3G Electric sources and coordinates all logistics to your location in the Philippines. Contact us for a specific delivery timeline and freight costs.

What thermal power and operating specifications does the FBR GAS XP 60/2 CE TC EVO burner deliver?

The FBR GAS XP 60/2 CE TC EVO delivers 116–630 kW thermal power in two-stage modulating operation with a 250 mm nozzle, IP 40 protection, and 66–69 dBA noise level. It draws 0.77 A at 1N~230V supply and suits medium to large-scale industrial heating applications.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
X GAS XP 60 CE TC EVO | Variant: variant_2 | Subgroup: Burner
FBR
X GAS XP 60 CE TC EVO | Variant: variant_2 | Subgroup: Burner
GAS XP 60/2 CE TL EVO | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60/2 CE TL EVO | Variant: variant_2 | Subgroup: Burner
X GAS XP 60 CE TL EVO | Variant: variant_2 | Subgroup: Burner
FBR
X GAS XP 60 CE TL EVO | Variant: variant_2 | Subgroup: Burner
GAS XP 60/2 CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60/2 CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 60/M CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60/M CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 60 CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 60 CE-LX TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL