We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR GAS P100/M is a two-stage gas burner for industrial heating applications, delivering 172–1000 Mcal/h thermal power with low-NOx fuel capability. Features modulating control, 1.5 kW fan motor, and IP 54…

SKU 3G-FBR-00416

Also listed as: 00240641 · 002406 41 · 002406-41

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
52 kg
stage
2 stages sliding or modulating
fuel type
Gas low nox
nozzle mm
250
fan motor w
1.5
power kw max
1450
power kw min
280
ip protection
IP 54
noisiness dba
81-82
gas consumption
20.1/58.3-116.7
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
3.6
thermal power mcal h
172/500-1000
nominal electric power w
1.7
max combustion air temp c
60

Datasheet Content

GAS BURNERS MODULATING LOW NOx WITH FGR GAS BURNERS MODULATING LOW NOX WITH FGR SK073014_C_en GAS XP60 - P100 - P150/M-LX-FGR-EL Burners for gas modulating (PID fully modulating) equipped with electronic control box LAMTEC BT3. They are composed by: die-cast aluminum body, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Gas train completely assembled and tested; complete of working valve with flow adjustment, safety valve, minimum gas pressure switch and gas filter. Complete of flange and gasket for installation on generator. The actuators are independent and are managed directly by the electronic cam: - one actuator for the gas modulator - one actuator for the air shutter - one actuator for the FGR shutter The burners are equipped with an operating display that allows: - Adjustment of the parameters of the burner operation - Adjustment of the setpoint and operation range of the pressure / temperature probe - Adjustment of the burner's curveset With the addition of optional accessories (probes) thanks to the most advanced systems for automatic modulation in mechanical or electronic version, the burner constantly ensures the proper gas / air ratio. The maximum efficiency of the returns in each combustion point derived from the punctual adaptation of the thermal load to the heat requirements of the burner at any instant of operation. In the version with the electronic cam the fuel / combustion air curve, more extended, is fully exploited, guaranteeing excellent performance in terms of accuracy and speed, even during the calibration phase. A microprocessor monitors the different stages of the process and allows the correct repetition of the sequences of operation. Some accessories are available, like: PC interface, VSD (inverter), O2 control, O2+CO control, Profibus, Modbus. Fig. 1 GAS P100/M-LX-FGR-EL GAS XP60 - P100 - P150/M-LX-FGR-EL GAS BURNERS MODULATING LOW NOX WITH FGR SK073014_C_en CONTROL BOX LAMTEC BT3 Fig. 2 Control box Lamtec BT3 PRINCIPLE OF OPERATION BURNER WITH FGR In these burners, to recirculate the exhaust gases from the flue it is used the combustion air fan. N.B. THE ACTION OF THE FUEL AND AIR ACTUATORS IS NOT AFFECTED BY THE FLUE GAS RECIRCULATION. The FGR damper stays closed at the beginning of the pre-purge period. After the adjusted delay (parameter 414 of the BT3 - factory setting: 10) the pre-purge time is stopped temporarily and the recirculation actuator runs to OPEN position. When the FGR actuator reach the pre-purge position (set to the parameter 367), the pre-purge time resumes. At the end of the pre-purge time the air damper and the FGR damper runs to the ignition position; the fuel actuator is already in the ignition position. When the BT3 reach the ignition positions of the actuators, the burner ignites. When the BT3 change it operation in "MODULATION MODE", only the fuel and the air actuators run to the programmed curve. The FGR actuator remains at its position until the release conditions were met: - Condition 1: The time period set in parameter 331 of the BT3 - factory setting: 200, it must be expired and - Condition 2: The release temperature of the flue gas set in parameter 332 of the BT3 - factory setting: 50, it must be reached. When the 2 conditions are met, the FGR actuator runs to the programmed curve. You can see the spent time and the FGR temperature on the BT3 operating panel after the "MODULATION MODE". If, during the operation of the burner, the FGR temperature drops below the threshold set in parameter 332, the recirculation channel rmains active. During the burner operation, the recirculation channel runs to the close position in one of these conditions: - Condition 1: If the flue gas temperature drops below 0°C or - Condition 2: If the Pt100 temperature probe it fails or interrupts N.B. IF ONE OF THESE TWO CONDITIONS HAPPENS, THE BURNER KEEP OPERATING WITHOUT THE FGR RECIRCULATION CHANNEL. SO ONLY AIR AND FUEL ACTUATORS WORK THROUGH THE PROGRAMMED CURVE. When you turn off the burner, the recirculation channel will be closed together with the fuel actuator. GAS XP60 - P100 - P150/M-LX-FGR-EL GAS BURNERS MODULATING LOW NOX WITH FGR SK073014_C_en FGR (FLUE GAS RECIRCULATION) FGR (flue gas recirculation) it is a technique for lowering NOx emissions from burners. FGR lowers NOx in two ways: 1) The cooled, relatively inert, recirculated flue gases act as a heat sink, absorbing heat from the flame and lowering peak flame temperatures. 2) When mixed with the combustion air, recirculated flue gases lower the average oxygen content of the air, starving the NOx-forming reaction for one of the ingredients they need. The percentage of the flue gas back to the combustion chamber it is defined by the opening of the FGR actuator damper. FGR quantity must be adjusted so as to recirculate the smallest quantity necessary to obtain the required Nox rate. DISADVANTAGES OF THE FGR SYSTEM LOSS OF THE BURNER CAPACITY If you replace the combustion air with low oxygen flue gases, the burner has to be downrated to compensate for the reduced weight of oxygen flowing through it. You'll also suffer an additional capacity loss because the flue gas/combustion air mixture is at elevated temperature. LOSS OF THE BURNER STABILITY AND FLEXIBILITY The FGR system can be increase the emissions of he carbon monoxide and unburned hydrocarbons. GAS XP60 - P100 - P150/M-LX-FGR-EL GAS BURNERS MODULATING LOW NOX WITH FGR SK073014_C_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS XP60/M-LX-FGR-EL MODEL GAS XP60/M-LX-FGR-EL Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 130/200-474 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 151/232-551 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 15.4/23.7-56 Fuel: NATURAL GAS (second family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R)B NOx ** [mg/kWh] <30 Intermittent operation (min.1 stop every 24h), modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Minimum pressure gas train D1"-S NATURAL GAS *** [mbar] 75 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [W] 935 Fan motor [W] 740 Nominal fan motor current absorption [A] 2 Nominal auxiliary absorption [A] 0.5 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** To obtain this low Nox emission like in the declaration, it's necessary to couple the burner to the proper boiler for this application: boilers with 3 turns for the exhaust gas, condensing boilers and any generator with direct exhaust outlet and the thermal load isn't higher then 1,8 MW/m³. *** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). >PEDU@ Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS XP60 - P100 - P150/M-LX-FGR-EL GAS BURNERS MODULATING LOW NOX WITH FGR SK073014_C_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS P100/M-LX-FGR-EL MODEL GAS P100/M-LX-FGR-EL Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 133/400-774 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 155/465-900 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 15.5/46.7-90.5 Fuel: NATURAL GAS (second family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R)B NOx ** [mg/kWh] <30 Continuous operation, modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Minimum pressure gas train D1"1/2-S NATURAL GAS *** [mbar] 34 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [kW] 2.7 Fan motor [kW] 2.2 Nominal fan motor current absorption [A] 5.4 Nominal auxiliary absorption [A] 0.5 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** To obtain this low Nox emission…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS P100/M is a two-stage gas burner for industrial heating applications, delivering 172–1000 Mcal/h thermal power with low-NOx fuel capability. Features modulating control, 1.5 kW fan motor, and IP 54 protection, suitable for medium to large-scale combustion systems.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR GAS P100/M gas burner in the Philippines?

Order from 3G Electric Philippines at www.3g-electric.com.ph. We source the FBR GAS P100/M and handle full logistics, Bureau of Customs documentation, and delivery to Manila and Quezon City. Lead time on request.

What is the thermal power output and lead time for the FBR GAS P100/M?

The FBR GAS P100/M delivers 172–1000 Mcal/h with two-stage or modulating control. Lead time depends on stock status; contact 3G Electric for availability and shipping schedule to your site in the Philippines.

Is the FBR GAS P100/M suitable for low-emission applications?

Yes. The FBR GAS P100/M is Class 4 low-NOx rated (NOx <60 mg/kWh) with optional modulation kit. It features IP 54 protection, 1.5 kW fan motor, and modulating control via PID probe for precise combustion in industrial heating systems.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS P100/M CE-LX4 TL EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS P100/M CE-LX4 TL EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS P 100/2 CE-LX4 TC EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 100/2 CE-LX4 TC EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS P 100/2 CE-LX4 TL EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 100/2 CE-LX4 TL EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS P100/M CE-LX4 TC EVO Cl. 4 | Variant: metano | Subgroup: Burner
FBR
GAS P100/M CE-LX4 TC EVO Cl. 4 | Variant: metano | Subgroup: Burner
GAS P 130/M CE-LX4 TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 130/M CE-LX4 TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
FBR
GAS P 130/2 CE-LX4 TC EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL