Supplying the Philippines from Singapore. Goods are offered EXW Singapore — collection from our Singapore facility.

3G Electric
FBR gpl subgroup burner - Gas burners
FBRGas burners

Fbr Gpl Subgroup Burner

16 sizes & variants — select below · Power KW Max 93–1450 · Power KW Min 17.4–300 · Gas Consumption: 8 options · Thermal Power Mcal H: 8 options

FBR GAS X2/M is a two-stage gas burner for industrial heating applications, delivering 17.4–93 kW across hi-low flame or modulating modes. Features 75 W fan motor, IP 40 protection, and 61–62 dB noise level, suitable…

WhatsApp an engineerMessage via Telegram
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted. Invoices in PHP are paid online through the payment link on the invoice.

Common specifications

FBR
Shared across the range — Power KW Max, Power KW Min, Gas Consumption, Thermal Power Mcal H vary by variant (see table below).
Weight
13 kg
Manufacturer Part Number
002733_31
stage
2 stages sliding or modulating
fuel type
Gas
nozzle mm
90
fan motor w
75
ip protection
IP 40
noisiness dba
61-62
electrical supply
1
power supply info
1N~230V 50Hz
current absorption a
0.6
nominal electric power w
130
max combustion air temp c
60

From the manufacturer's datasheet

FBR
Models
GAS X2/MCE, GAS X3/MCE, GAS X4/MCE
Thermal power min. 1st stage / min. 2nd stage - max. 2nd sta
17/41-93, 35/70-174, 46/116-232
Gas flow G20 (natural gas) min. 1st / min. 2nd - max. 2nd [N
1.7/4.1-9.4, 3.5/7-17.4, 4.6/11.6-23.2
Gas flow G31 (L.P.G.) min. 1st / min. 2nd - max. 2nd [Nm³/h]
0.7/1.6-3.6, 1.3/2.7-6.5, 1.8/4.5-9
Fuel category
I2R, I2H, I2L, I2E, I2E+, I2Er, I2ELL, I2E(R), I3B/P, I3+, I3P, I3B, I3R
Max. temperature combustion air [°C]
60
Minimum pressure gas train [mbar]
D3/4"-S: 18/24; D1"-S: 14/31 (X3), 14/21 (X4); D1"1/4-S: 11/29.5 (X3), 11/19 (X4
Maximum pressure at entry of valves [mbar]
360
Features
  • Two stages progressive (hi-low flame) or modulating (PID) with optional kit
  • Fan at high pressurisation
  • Combustion head with adjustment for high efficiency and flame stability
  • Protection cover with noise reduction plate
  • Gas train completely assembled and tested with one-block valve A class
  • Available for methane, L.P.G., town gas, coal gas, or biogas
Typical applications
Industrial boilersHot water generatorsSteam generatorsAir heaters
Intermitted working operation: min. 1 stop every 24 hours.
For correct operation, combustion chamber dimensions must be in accordance with current regulation; in case of non-compliance, contact the manufacturer.

Technical Documents

No technical documents available for this product.
Request documentation →
Select a size

Showing 16 / 16 variants — scroll the table for more

Part No (MPN)002411_413G SKU3G-FBR-00419Power KW Max850Power KW Min170Gas Consumption17/40.8-85.3Thermal Power Mcal H146/350-731
Part No (MPN)002422_413G SKU3G-FBR-00423Power KW Max850Power KW Min170Gas Consumption17/40.8-85.3Thermal Power Mcal H146/350-731
Part No (MPN)002450_413G SKU3G-FBR-00428Power KW Max630Power KW Min107Gas Consumption10.7/23.3-63.3Thermal Power Mcal H92/200-542
Part No (MPN)002451_413G SKU3G-FBR-00429Power KW Max630Power KW Min107Gas Consumption10.7/23.3-63.3Thermal Power Mcal H92/200-542
Part No (MPN)002463_313G SKU3G-FBR-00438Power KW Max1450Power KW Min300Gas Consumption30.2/71.5-146Thermal Power Mcal H258/612-1247
Part No (MPN)002464_313G SKU3G-FBR-00439Power KW Max1450Power KW Min300Gas Consumption30.2/71.5-146Thermal Power Mcal H258/612-1247
Part No (MPN)002478_413G SKU3G-FBR-00448Power KW Max1163Power KW Min192Gas Consumption20.1/58.3-116.17Thermal Power Mcal H172/500-1000
Part No (MPN)002479_413G SKU3G-FBR-00449Power KW Max1163Power KW Min192Gas Consumption20.1/58.3-116.17Thermal Power Mcal H172/500-1000
Part No (MPN)002704_313G SKU3G-FBR-00502Power KW Max174Power KW Min34.9Gas Consumption3.5/7-17.4Thermal Power Mcal H30/60-150
Part No (MPN)002705_313G SKU3G-FBR-00503Power KW Max174Power KW Min34.9Gas Consumption3.5/7-17.4Thermal Power Mcal H30/60-150
Part No (MPN)002708_313G SKU3G-FBR-00506Power KW Max232Power KW Min46.5Gas Consumption4.6/11.6-23.2Thermal Power Mcal H40/100-200
Part No (MPN)002709_313G SKU3G-FBR-00507Power KW Max232Power KW Min46.5Gas Consumption4.6/11.6-23.2Thermal Power Mcal H40/100-200
Part No (MPN)002733_313G SKU3G-FBR-00510Power KW Max93Power KW Min17.4Gas Consumption1.7/4.1-9.4Thermal Power Mcal H15/35-80
Part No (MPN)002734_313G SKU3G-FBR-00511Power KW Max93Power KW Min17.4Gas Consumption1.7/4.1-9.4Thermal Power Mcal H15/35-80
Part No (MPN)002766_413G SKU3G-FBR-00522Power KW Max349Power KW Min69.8Gas Consumption7/15.2-35Thermal Power Mcal H60/130-300
Part No (MPN)002767_413G SKU3G-FBR-00523Power KW Max349Power KW Min69.8Gas Consumption7/15.2-35Thermal Power Mcal H60/130-300
Not sure this is the right part? Get a recommendation.

Ask a question

Request a Quote

Ask a question

Frequently Asked Questions

What are the available fuel types?

Natural gas (methane) or L.P.G. (to specify at order); on demand specific versions for town gas, coal gas or biogas.

What is the maximum combustion air temperature?

60°C for all models.

What is the maximum pressure at the entry of valves?

360 mbar for all models.

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first

FBR Products

3G Electric supplies FBR gas burners. We supply genuine products and their technical documentation.

You might also need

Gas Trains & Valves →Ignition Transformers →Burner Controls →Spare Parts →All Products →

More from FBR

View all FBR parts →
GAS X2 CE-LX TC Cl. | Variant: metano | Subgroup: Burner
FBR
GAS X2 CE-LX TC Cl. | Variant: metano | Subgroup: Burner
GAS P 450/M CE-LX FIR TL EL | Variant: metano | Option: EVO (1) Cl. 3
FBR
GAS P 450/M CE-LX FIR TL EL | Variant: metano | Option: EVO (1) Cl. 3
G X5 24V
FBR
G X5 24V
X GAS X5 CE TC | Variant: metano | Subgroup: Burner
FBR
X GAS X5 CE TC | Variant: metano | Subgroup: Burner
GAS XP 60/M CE TC EVO | Variant: metano | Subgroup: Burner
FBR
GAS XP 60/M CE TC EVO | Variant: metano | Subgroup: Burner
GAS P 350/M CE TL EL EVO (1) | Variant: variant_1 | Subgroup: Burner with electronic cam
FBR
GAS P 350/M CE TL EL EVO (1) | Variant: variant_1 | Subgroup: Burner with electronic cam
GAS X1 CE-LX TL Cl. | Variant: variant_2 | Subgroup: Burner
FBR
GAS X1 CE-LX TL Cl. | Variant: variant_2 | Subgroup: Burner
GAS X2/M CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS X2/M CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner