We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR GPL - Burners & Combustion
FBRBurners & Combustion

FBR GPL

FBR GAS P 130/2 is a two-stage gas burner for industrial heating applications, delivering low NOx emissions below 60 mg/kWh. It provides thermal power up to 1247 mcal/h with a 2.2 kW fan motor and operates at IP 40…

SKU 3G-FBR-00438

Also listed as: 00246331 · 002463 31 · 002463-31

Brand
FBR
Item
GPL
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
44 kg
stage
2 stages
fuel type
Gas low nox
nozzle mm
280
fan motor w
2.2
power kw max
1450
power kw min
300
ip protection
IP 40
noisiness dba
82-83
gas consumption
30.2/71.5-146
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
4.35
thermal power mcal h
258/612-1247
nominal electric power w
2.4
max combustion air temp c
60

Datasheet Content

GAS BURNER LOW NOX (CLASS 4) TWO STAGES 071100_A_en mod: GAS P130/2CE LX4 EVO GASBURNERSLOWNOX(CLASS4)TWO STAGES GAS P130/2CE LX4 EVO Gas burner two stages with: die-cast aluminum body, high pressurisation air blower with reverse blades and combustion head at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for easy setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order). Gas train completely assembled and tested; composed by two stages working valve with flow adjustment, safety valve, minimum gas pressure switch, valve proving system and gas filter + gas pressure stabiliser. Complete of flange and gasket for installation on generator. Fig. GAS P130/2CE LX4 EVO GAS P130/2CE LX4 EVO GAS BURNER LOW NOX (CLASS 4) TWO STAGES 071100_A_en mod: GAS P130/2CE LX4 EVO TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS P130/2CE LX4 EVO MODEL GAS P130/2CE LX4 EVO Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 258/612-1247 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 300/712-1450 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 30.2/71.5-146 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 11.6/27.6-56.2 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R),I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Minimum pressure gas train D2"-S NATURAL GAS/L.P.G. ** [mbar] 52.8/28 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [kW] 2.4 Fan motor [kW] 2.2 Nominal motor current absorption [A] 4.35 Nominal auxiliary absorption [A] 0.7 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 NOx Class, NATURAL GAS (second family) 4 NOx Class, L.P.G. (third family) 4 Noisiness *** min. - max. [dB(A)] 82-83 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - Control method class 3 - The measured sound pressure tolerance can be assumed to be ± 1 [dB (A)]). GAS P130/2CE LX4 EVO 071100_A_en GAS BURNER LOW NOX (CLASS 4) TWO STAGES mod: GAS P130/2CE LX4 EVO 18 GAS P130/2CE‐LX4 EVO 16 14 12 10 8 6 4 2 0 0 200 400 600 800 1000 1200 1400 1600 1800 Fig. X = Thermal power [kW] Y = Pression in the combustion chamber [mbar] The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. GAS P130/2CE LX4 EVO 071100_A_en GAS BURNER LOW NOX (CLASS 4) TWO STAGES mod: GAS P130/2CE LX4 EVO DIMENSIONS [MM] 40 183 320 320 320 211 320 O 209 284 284 20 510 TC-TL 240 343 148 B 380 803 - 1388** A Fig. Dimensions GAS P130/2 CE LX4 EVO GAS TRAIN A B ** Overall dimension with the burner out in position of maintenance. D2"-S 555 396 TC - TL: see "flame tube length" GAS P130/2CE LX4 EVO 071100_A_en GAS BURNER LOW NOX (CLASS 4) TWO STAGES mod: GAS P130/2CE LX4 EVO BOILER PLATE The dimensions of the boiler plate must be as indicated in the drawing. *** Suggested dimension of connection between burner and generator. MODEL L min L*** L max M N min N max GAS P130/2CE LX4 EVO mm 220 220 250 M14 340 368 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. FLAME TUBE LENGTH TC mm 280 TL mm 400 **** **** For different flame lengths, please contact our Technical-Sales Department. GAS P130/2CE LX4 EVO 071100_A_en GAS BURNER LOW NOX (CLASS 4) TWO STAGES mod: GAS P130/2CE LX4 EVO BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 V V 1 Fig. Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). GAS P130/2CE LX4 EVO 071100_A_en GAS BURNER LOW NOX (CLASS 4) TWO STAGES mod: GAS P130/2CE LX4 EVO PRODUCT SPECIFICATION SHORT DESCRIPTION Gas burner two stages low emissions class 4 (NOx < 60 mg/kWh). DETAILED SPECIFICATION Gas burner two stages low emissions class 4 (NOx < 60 mg/kWh). composed by: • Die-cast aluminum body; • High pressurisation air blower with reverse blades; • Combustion head at high performance and elevated flame stability equipped with inox steel blast tube and inox steel flame disc; • Flange and…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS P 130/2 is a two-stage gas burner for industrial heating applications, delivering low NOx emissions below 60 mg/kWh. It provides thermal power up to 1247 mcal/h with a 2.2 kW fan motor and operates at IP 40 protection. Suitable for commercial and industrial combustion systems.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR GAS P 130/2 gas burner in the Philippines?

3G Electric Philippines sources the FBR GAS P 130/2 for delivery to Manila and Quezon City. We handle all Bureau of Customs documentation, logistics, and PHP invoicing. Lead time on request — contact us for availability and freight quotes.

What is the lead time and shipping for the FBR GAS P 130/2?

Lead time varies based on current sourcing. 3G Electric manages full logistics to Philippines destinations including CALABARZON facilities. We arrange customs clearance and provide PHP invoicing. Request a quote for your delivery timeline.

What are the emissions and power specifications of the FBR GAS P 130/2?

The FBR GAS P 130/2 delivers NOx emissions below 60 mg/kWh (Class 4), maximum thermal power 1450 kW, minimum 300 kW. It features a 2.2 kW fan motor, IP 40 protection, and operates on 3~400V 50Hz electrical supply with 4.35 A current absorption.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS P 130/2 CE-LX4 TL EVO Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
GAS P 130/2 CE-LX4 TL EVO Cl. 4 | Variant: GPL | Subgroup: Burner
GAS P 100/2 CE-LX4 TC EVO Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
GAS P 100/2 CE-LX4 TC EVO Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
FBR
GAS P 130/2 CE-LX4 TC EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS P 130/M CE-LX4 TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 130/M CE-LX4 TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS P 100/2 CE-LX4 TL EVO Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
GAS P 100/2 CE-LX4 TL EVO Cl. 4 | Variant: GPL | Subgroup: Burner
GAS P 130/M CE-LX4 TL EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS P 130/M CE-LX4 TL EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL