Datasheet Content
SK071098_A_en
GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO
GAS P160/2CE
GAS P130/2CE EVO - GAS P160/2CE
Gas burners two stages with: die-cast aluminum body, high pressurisation air blower and combustion head with
adjustment at high efficiency and high flame stability.
Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for easy
setting and maintenance.
Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions
for town gas, coal gas or biogas.
Gas train completely assembled and tested; composed by two stages working valve with flow adjustment, safety
valve, minimum gas pressure switch, valve proving system and gas filter + gas pressure stabiliser.
Complete of flange and gasket for installation on generator.
SK071098_A_en
GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO
GAS P160/2CE
TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS P130/2CE EVO - GAS P160/2CE
MODEL GAS P130/2CE EVO GAS P160/2CE
Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 206/612-1324 258/765-1647
Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 240/712-1540 300/890-1915
Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 24/71.5-155 30.2/89.5-192
Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 9.3/27.6-59.8 11.6/34.5-74.2
Fuel: NATURAL GAS (second family) - L.P.G. (third family)
Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R),I3B/P,I3+,I3P,I3B,I3R
Intermitted working operation (min. 1 stop every 24 hours) two stages
Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80%
Max. temperature combustion air [°C] 60 60
Min. pressure gas train D2"-S NATURAL GAS/L.P.G. ** [mbar] 52.4/28.2 64.5/40.4
Maximum pressure at the entry of valves (Pe. max) [mbar] 360 360
Nominal electric power [kW] 2.4 4.2
Fan motor [kW] 2.2 4
Nominal motor current absorption [A] 4.35 7.45
Nominal auxiliary absorption [A] 0.7 0.7
Power supply: 3~400V, 1/N~230V-50Hz
Electric protection degree: IP 40
Noisiness *** min. - max [dB(A)] 82-83 84.3-86.6
* Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level).
** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber
of value 0 (zero).
*** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 -
Control method Class 3 - The tolerance on the measured sound pressure can be assumed equal to ± 1 [dB (A)]).
GAS P130/2CE EVO - GAS P160/2CE
SK071098_A_en
GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO
GAS P160/2CE
18
GAS P130/2CE EVO
16
14
12
10
8
6
4
2
0
0 200 400 600 800 1000 1200 1400 1600 1800
Fig. X = Thermal power [kW] Y = Pression in the combustion chamber [mbar]
GAS P130/2CE EVO
The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the
boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of
non-compliance, contact the manufacturer.
16
GAS P160/2CE
14
12
10
8
6
4
2
0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
Fig. X = Thermal power [kW] Y = Pression in the combustion chamber [mbar]
GAS P160/2CE
The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the
boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-
compliance, contact the manufacturer.
GAS P130/2CE EVO - GAS P160/2CE
SK071098_A_en
GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO
GAS P160/2CE
DIMENSIONS [MM]
320
40 183 211
320
O 209
320 284
20 510
320
TC-TL 148
240 343 545
380 803 - 1388 **
555
Fig. Dimensions GAS P130/2CE EVO
320
40 183 211
320
O 209
320 284
20
510
320 TC-TL 148
240 402 545
380 803 - 1388 **
555
Fig. Dimensions GAS P160/2CE
** Overall dimension with the burner out in position of maintenance.
TC - TL: See "FLAME TUBE LENGTH"
GAS P130/2CE EVO - GAS P160/2CE
SK071098_A_en
GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO
GAS P160/2CE
BOILER PLATE
The dimensions of the burner fixing flange (holes
threaded or studded) must be as per the drawing.
*** Recommended hole diameter on the generator.
MODEL L min L*** L max M N min N
max
GAS P130/2CE EVO mm 220 220 250 M14 340 368
GAS P160/2CE mm 220 220 250 M14 340 368
FLAME TUBE LENGTH
Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it
must be greater than the thickness of the boiler door included its insulation.
In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between
the flame tube and front door with refractory material. This protection material must not impede flame tube
extraction.
FLAME TUBE LENGTH
TC mm 280
TL mm 400 ****
**** For different flame lengths, please contact our Technical-Sales Department.
GAS P130/2CE EVO - GAS P160/2CE
SK071098_A_en
GAS BURNERS TWO STAGES mod: GAS P130/2CE EVO
GAS P160/2CE
BURNER SIGNAL DESCRIPTION
In the picture below there are indicated all the signalation present on the burner:
2
V
V
1
'
Fig. Burner signal description
LEGEND
1) ON/OFF button
2) Reset from lockout button + status lamp
The multicolor signal lamp in the…