We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR GPL - Burners & Combustion
FBRBurners & Combustion

FBR GPL

FBR GAS P 100/2 is a two-stage gas burner for industrial heating applications, delivering 192–1163 kW with low NOx emissions (< 60 mg/kW). Operates on 3~400V, 50Hz electrical supply with IP 40 protection, suitable…

SKU 3G-FBR-00448

Also listed as: 00247841 · 002478 41 · 002478-41

Brand
FBR
Item
GPL
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
44 kg
stage
2 stages
fuel type
Gas low nox
nozzle mm
250
fan motor w
1.5
power kw max
1163
power kw min
192
ip protection
IP 40
noisiness dba
81-82
gas consumption
20.1/58.3-116.17
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
3.6
thermal power mcal h
172/500-1000
nominal electric power w
1.7
max combustion air temp c
60

Datasheet Content

GAS BURNERS LOW NOX (CLASS 4) TWO STAGES 071100_B_gb GAS BURNERS LOW NOX (CLASS 4) TWO STAGES GAS P100/2 CE LX4 EVO Gas burners two stages with: aluminum body, fan at high pressurisation at reverse blades and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order). Gas train completely assembled, electrically linked and tested; complete of two stages working valve with flow adjustment, safety valve, minimum gas pressure switch and stabiliser filter of gas pressure. Complete of flange and gasket for installation on generator. ' Fig. 1 GAS P100/2 CE LX4 EVO GAS P100/2 CE LX4 EVO GAS BURNERS LOW NOX (CLASS 4) TWO STAGES 071100_B_gb TECHNICAL DATA AND OPERATING RANGE DIAGRAM GAS P100/2 CE LX4 EVO MODEL GAS P100/2 CE LX4 EVO Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 172/500-1000 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 200/581-1163 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 20.1/58.3-116.17 Gas flow G25 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 23.3/67.8-135.7 Gas flow G25.3 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. [Nm³/h] 22.8/66.3-132.7 * Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 11.2/22.5-45.1 Fuel: NATURAL GAS (second family, G20, G25, G25.3) - L.P.G. (third family, G31) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R),I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Minimum pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 93/60 Minimum pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 42/38 Minimum pressure gas train D2"-S NATURAL GAS/L.P.G. ** [mbar] 32/35 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [kW] 1.7 Fan motor [kW] 1.5 Nominal motor current absorption [A] 3.6 Nominal auxiliary absorption [A] 0.7 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 NOx Class, NATURAL GAS (second family) 4 NOx Class, L.P.G. (third family) 4 Noisiness *** min. - max. [dB(A)] 81-82 Burner weight **** [kg] 44 * For L.P.G. Minimum 1st stage power: 249 Mcal/h - 290 kW. Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - Control method class 3 - The measured sound pressure tolerance can be assumed to be ± 1 [dB (A)]). **** For burner with long head add 2 kg to the weight. GAS P100/2 CE LX4 EVO GAS BURNERS LOW NOX (CLASS 4) TWO STAGES 071100_B_gb [mbar] 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 [kW] Fig. 2 X = Thermal power Y = Pression in the combustion chamber For L.P.G. Minimum 1st stage power: 249 Mcal/h - 290 kW. The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS P100/2 CE LX4 EVO GAS BURNERS LOW NOX (CLASS 4) TWO STAGES 071100_B_gb DIMENSIONS [MM] 290 280 240 380 294 A 25 140 185 266 510 TC - TL 181 B ' 764 Fig. 3 Dimensions GAS TRAIN A B D1"1/4-S 437 382* D1"1/2-S 458 396 D2"-S 458 396 * Includes length of 66 mm due to adapter code 057020 TC - TL: Please see chapter "Flame tube length" GAS P100/2 CE LX4 EVO GAS BURNERS LOW NOX (CLASS 4) TWO STAGES 071100_B_gb BOILER PLATE The dimensions of the boiler plate must be as indicated in the drawing. * Suggested dimension of connection between burner and generator. MODEL L min L* L max M N min N max GAS P100/2 CE LX4 EVO mm 195 195 250 M12 275 325 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. FLAME TUBE LENGTH TC mm 252 TL mm 387 * * For different flame lengths, please contact our Technical-Sales Department. GAS P100/2 CE LX4 EVO GAS BURNERS LOW NOX (CLASS 4) TWO STAGES 071100_B_gb BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 1 V V ' Fig. 4 Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). GAS P100/2 CE LX4 EVO GAS BURNERS LOW NOX (CLASS 4) TWO STAGES 071100_B_gb PRODUCT SPECIFICATION SHORT DESCRIPTION Gas burners two stages low emissions class 4 (NOx < 60 mg/kWh). DETAILED SPECIFICATION Gas burner two stages low emissions class 4 (NOx < 60 mg/kWh). composed by: • Aluminum body; • Fan at high pressurisationwith reverse blades; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and inox steel flame disc; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Gas train with safety valve class A, adjustment two stages valve class A; • Optional valve proving system; • Ionisation probe for flame detection; • IP 40 electric protection level; • Servomotor for air shutter and for the consent of the 2nd stage gas valve; • Moving shutter with total closure when idle in order to reduce at the least energy losses related to boiler cooling down; • Maximum gas pressure switch to stop the burner in lock-out in case of the gas…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS P 100/2 is a two-stage gas burner for industrial heating applications, delivering 192–1163 kW with low NOx emissions (< 60 mg/kW). Operates on 3~400V, 50Hz electrical supply with IP 40 protection, suitable for large-scale combustion systems.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy an FBR GAS P 100/2 burner in the Philippines?

3G Electric Philippines sources the FBR GAS P 100/2 for delivery to Manila and Quezon City. We handle Bureau of Customs documentation, logistics coordination, and PHP invoicing. Contact us for availability and lead time on this two-stage 1163 kW burner.

What is the lead time and delivery for the FBR GAS P 100/2 to the Philippines?

Lead time is available on request. 3G Electric coordinates all shipping logistics and customs clearance to your site in the Philippines. Standard delivery covers Manila and Quezon City regions. Contact us with your project timeline for a firm quote.

What are the power and emissions specifications of the FBR GAS P 100/2?

The FBR GAS P 100/2 delivers 192–1163 kW in two stages with low NOx emissions below 60 mg/kWh. It operates on 3~400V, 50 Hz supply, draws 3.6 A, and carries CE-LX4 Class 4 certification. IP 40 protection suits large-scale industrial combustion systems.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS P 100/2 CE-LX4 TL EVO Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
GAS P 100/2 CE-LX4 TL EVO Cl. 4 | Variant: GPL | Subgroup: Burner
GAS P 130/2 CE-LX4 TC EVO Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
GAS P 130/2 CE-LX4 TC EVO Cl. 4 | Variant: GPL | Subgroup: Burner
GAS P 130/2 CE-LX4 TL EVO Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
GAS P 130/2 CE-LX4 TL EVO Cl. 4 | Variant: GPL | Subgroup: Burner
GAS P 100/2 CE-LX4 TC EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 100/2 CE-LX4 TC EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS P 100/2 CE-LX4 TL EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
FBR
GAS P 100/2 CE-LX4 TL EVO Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS P100/M CE-LX4 TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS P100/M CE-LX4 TC EVO Cl. 4 | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL