We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FUJI ELECTRIC PRV6011 Pressure Relief Valve, 232 in wc Preset, 2 in OD - Pressure & Vacuum Relief Valves for Regenerative Blowers
FUJI ELECTRICPressure & Vacuum Relief Valves for Regenerative Blowers

FUJI ELECTRIC PRV6011 Pressure Relief Valve, 232 in wc Preset, 2 in OD

The FUJI ELECTRIC Blower Relief Valve: Pressure (MPN PRV6011) is a pressure and vacuum relief valve designed for regenerative blowers. It features a 232 in wc preset limit and a 2 in outside diameter. This valve is…

SKU 3G-OTH-142218

Also listed as: PRV 6011 · PRV-6011

Brand
FUJI ELECTRIC
Item
PRV6011 Pressure Relief Valve, 232 in wc Preset, 2 in OD
Category
Pressure & Vacuum Relief Valves for Regenerative Blowers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FUJI ELECTRIC
Manufacturer Part Number
PRV6011
Type
232 in wc Preset Limit
Outside Dia
2 in

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FUJI ELECTRIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FUJI ELECTRIC Blower Relief Valve: Pressure (MPN PRV6011) is a pressure and vacuum relief valve designed for regenerative blowers. It features a 232 in wc preset limit and a 2 in outside diameter. This valve is identified by model number 2VFB60-11.5-7W and is manufactured by FUJI ELECTRIC.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the FUJI ELECTRIC Blower Relief Valve PRV6011 used for?

The FUJI ELECTRIC Blower Relief Valve PRV6011 is a pressure and vacuum relief valve designed for regenerative blowers. It protects the blower system from overpressure by venting excess air at a preset limit of 232 in wc, ensuring safe and reliable operation in industrial air-handling applications.

What are the specifications of the FUJI ELECTRIC PRV6011 relief valve?

The FUJI ELECTRIC PRV6011 is a pressure relief valve with a 232 in wc preset limit and a 2 in outside diameter. It is identified by model number 2VFB60-11.5-7W and manufacturer part number PRV6011. This valve is designed specifically for use with FUJI ELECTRIC regenerative blowers.

Where to buy the FUJI ELECTRIC PRV6011 relief valve worldwide?

3G Electric supplies the FUJI ELECTRIC PRV6011 blower relief valve worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact our team to source this valve for your regenerative blower system.

How to install the FUJI ELECTRIC PRV6011 blower relief valve?

Install the FUJI ELECTRIC PRV6011 by mounting it directly to the blower discharge port using the 2 in outside diameter connection. Ensure the valve is oriented vertically for proper operation. Tighten fittings to manufacturer torque specs and verify the preset limit of 232 in wc before startup. Always follow FUJI ELECTRIC installation guidelines.

Used in

Common applications for FUJI ELECTRIC
HVAC systems — Fuji FRENIC Ace VFDs for variable-speed control of fans and pumps in commercial buildings
Water treatment — Fuji FRENIC Mega VFDs for regulating pump speed in filtration and distribution systems
Conveyor systems — Fuji FRENIC Ace VFDs for speed control of material handling conveyors in manufacturing
Pneumatic conveying — Fuji Electric VRV50 relief valve for protecting regenerative blowers in bulk material transport
Compressor control — Fuji FRENIC Mega VFDs for adjusting compressor motor speed to match air demand

FUJI ELECTRIC Products

3G Electric supplies FUJI ELECTRIC pressure & vacuum relief valves for regenerative blowers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This pressure and vacuum relief valve is designed for use with regenerative blowers. It features a 190 in wc preset limit and a 2 in outside diameter. The valve protects the blower system from overpressure by venting excess air when the preset limit is reached
FUJI ELECTRIC
This pressure and vacuum relief valve is designed for use with regenerative blowers. It features a 190 in wc preset limit and a 2 in outside diameter. The valve protects the blower system from overpressure by venting excess air when the preset limit is reached
FUJI ELECTRIC Blower Relief Valve: Pressure, 180 in wc Preset Limit, 2 in Outside Dia (MPN PRV50)
FUJI ELECTRIC
FUJI ELECTRIC Blower Relief Valve: Pressure, 180 in wc Preset Limit, 2 in Outside Dia (MPN PRV50)
This pressure and vacuum relief valve is designed for regenerative blowers. It features a 95 in wc preset limit and a 1.5 in outside diameter. The valve vents excess air to protect the blower system from overpressure, ensuring safe operation in pneumatic applications
FUJI ELECTRIC
This pressure and vacuum relief valve is designed for regenerative blowers. It features a 95 in wc preset limit and a 1.5 in outside diameter. The valve vents excess air to protect the blower system from overpressure, ensuring safe operation in pneumatic applications
Pressure and vacuum relief valve for regenerative blowers. Preset limit of 159 in wc. Outside diameter 1.5 in. Protects blower systems from overpressure by venting excess air
FUJI ELECTRIC
Pressure and vacuum relief valve for regenerative blowers. Preset limit of 159 in wc. Outside diameter 1.5 in. Protects blower systems from overpressure by venting excess air
This pressure and vacuum relief valve is designed for use with regenerative blowers. It features a preset limit of 118 in wc and a 1.5 in outside diameter. The valve vents excess air to protect the blower system from overpressure conditions
FUJI ELECTRIC
This pressure and vacuum relief valve is designed for use with regenerative blowers. It features a preset limit of 118 in wc and a 1.5 in outside diameter. The valve vents excess air to protect the blower system from overpressure conditions
FUJI ELECTRIC Blower Relief Valve: Vacuum, 95 in wc Preset Limit, 1.5 in Outside Dia (MPN VRV305)
FUJI ELECTRIC
FUJI ELECTRIC Blower Relief Valve: Vacuum, 95 in wc Preset Limit, 1.5 in Outside Dia (MPN VRV305)

More from FUJI ELECTRIC

View all FUJI ELECTRIC parts
The VRV40 is a pressure and vacuum relief valve for regenerative blowers, with a preset limit of 133 in wc and an outside diameter of 1.5 in. It vents excess pressure or vacuum to protect system components in pneumatic conveying, aeration, and vacuum applications
FUJI ELECTRIC
The VRV40 is a pressure and vacuum relief valve for regenerative blowers, with a preset limit of 133 in wc and an outside diameter of 1.5 in. It vents excess pressure or vacuum to protect system components in pneumatic conveying, aeration, and vacuum applications
Pressure and vacuum relief valve for regenerative blowers. Preset limit of 127 in wc. Outside diameter of 2 in. Protects blowers from overpressure or vacuum conditions in industrial air-moving systems
FUJI ELECTRIC
Pressure and vacuum relief valve for regenerative blowers. Preset limit of 127 in wc. Outside diameter of 2 in. Protects blowers from overpressure or vacuum conditions in industrial air-moving systems
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a 42 in wc preset limit and a 1.5 in outside diameter. The valve vents excess pressure to protect the system from damage
FUJI ELECTRIC
This pressure and vacuum relief valve is designed for use with regenerative blowers in industrial air-handling systems. It features a 42 in wc preset limit and a 1.5 in outside diameter. The valve vents excess pressure to protect the system from damage
FUJI ELECTRIC
FUJI ELECTRIC
The FUJI ELECTRIC VRV2000 is a pressure and vacuum relief valve for regenerative blowers. It opens at a preset limit of 118 in wc to protect against over-vacuum conditions. With a 2.5 in outside diameter, it is suited for industrial air-moving systems requiring vacuum relief
This pressure and vacuum relief valve is designed for regenerative blowers in industrial air-handling systems. It features a 175 in wc preset vacuum limit and a 2 in outside diameter, opening at the preset limit to protect the blower from excessive vacuum and maintain system stability
FUJI ELECTRIC
This pressure and vacuum relief valve is designed for regenerative blowers in industrial air-handling systems. It features a 175 in wc preset vacuum limit and a 2 in outside diameter, opening at the preset limit to protect the blower from excessive vacuum and maintain system stability
FUJI ELECTRIC
FUJI ELECTRIC
Pressure and vacuum relief valve for regenerative blowers. Features a 110 in wc preset limit and 2 in outside diameter. Vents excess pressure to protect system components in pneumatic conveying and aeration applications
FUJI ELECTRIC
FUJI ELECTRIC
This pressure and vacuum relief valve is designed for regenerative blowers. It features a 95 in wc preset limit and a 2 in outside diameter. The valve opens at the preset vacuum limit to protect the system from over-vacuum conditions
Pressure and vacuum relief valve for regenerative blowers. Preset limit of 100 in wc. Outside diameter of 2 in. Used to protect blower systems from overpressure in industrial air handling, pneumatic conveying, and vacuum applications
FUJI ELECTRIC
Pressure and vacuum relief valve for regenerative blowers. Preset limit of 100 in wc. Outside diameter of 2 in. Used to protect blower systems from overpressure in industrial air handling, pneumatic conveying, and vacuum applications