We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

3G Electric
FRANKLIN ELECTRIC 3NC-557P3-196 Non-Clog Sewage Ejector Pump - Non-Clog Sewage Ejector Pumps
FRANKLIN ELECTRICNon-Clog Sewage Ejector Pumps

FRANKLIN ELECTRIC 3NC-557P3-196 Non-Clog Sewage Ejector Pump

The FRANKLIN ELECTRIC Sewage Ejector Pump is a cast-iron, non-clog sewage ejector pump with a horizontal discharge orientation. It is a three-phase, 5 hp unit rated at 575V AC and 60 Hz, with a maximum head of 58 ft…

SKU 3G-OTH-85029

Also listed as: 3NC557P3196 · 3NC 557P3 196

Brand
FRANKLIN ELECTRIC
Item
3NC-557P3-196 Non-Clog Sewage Ejector Pump
Part Number
3NC-557P3-196
Category
Non-Clog Sewage Ejector Pumps
Available to Order
Also known as:3NC-557P3-196FRANKLIN ELECTRIC
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FRANKLIN ELECTRIC
Manufacturer Part Number
3NC-557P3-196
Type
Three Phase, 5 hp, 60 Hz
AC
575V
Switch
Not Included
Max. Head
58 ft
Rated Voltage
575V AC
Impeller Material
Ductile Iron
Discharge Orientation
Horizontal

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FRANKLIN ELECTRIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FRANKLIN ELECTRIC Sewage Ejector Pump is a cast-iron, non-clog sewage ejector pump with a horizontal discharge orientation. It is a three-phase, 5 hp unit rated at 575V AC and 60 Hz, with a maximum head of 58 ft. The impeller is made of ductile iron, and the pump does not include a switch.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is a FRANKLIN ELECTRIC sewage ejector pump used for?

This non-clog sewage ejector pump moves wastewater containing solids from below-grade fixtures (basements, septic tanks) to a higher-level sewer line. Its ductile iron impeller and cast-iron housing handle abrasive debris in municipal, commercial, and industrial wastewater applications.

What are the specifications of the FRANKLIN ELECTRIC 3NC-557P3-196 pump?

The FRANKLIN ELECTRIC 3NC-557P3-196 is a three-phase, 5 hp, 575V AC, 60 Hz sewage ejector pump with a maximum head of 58 ft. It features a ductile iron impeller, horizontal discharge orientation, and does not include a switch. The manufacturer part number is 3NC-557P3-196.

Where to buy a FRANKLIN ELECTRIC sewage ejector pump worldwide?

3G Electric supplies the FRANKLIN ELECTRIC 3NC-557P3-196 sewage ejector pump to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact our team for a quote and lead time on this non-clog pump.

How to install a FRANKLIN ELECTRIC sewage ejector pump?

Install the pump on a firm, level base in the wet well with the horizontal discharge aligned to the piping. Ensure the 575V AC three-phase power supply matches the motor rating. Do not operate without a properly sized control panel, as the pump does not include a switch.

Used in

Common applications for FRANKLIN ELECTRIC
Residential water supply — Franklin Electric simplex pump control panels for submersible deep-well pumps
HVAC condensate management — Franklin Electric condensate removal pump with safety switch for plenum-rated installations
Municipal wastewater handling — Franklin Electric non-clog sewage ejector pump handling solids up to 3 inches
Agricultural irrigation — Franklin Electric pump control panels rated for 230V AC single-phase operation
Industrial motor maintenance — Franklin Electric 230V relays for replacement in pumping systems
Not sure this is the right part? Photo-identify it

FRANKLIN ELECTRIC Products

3G Electric supplies FRANKLIN ELECTRIC non-clog sewage ejector pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from FRANKLIN ELECTRIC

View all FRANKLIN ELECTRIC parts
This non-clog sewage ejector pump features a cast iron construction with a ductile iron impeller and horizontal discharge. It is powered by a 3 hp three-phase motor rated for 200 to 230V AC, delivering a maximum head of 42 ft. Designed for handling wastewater and effluent in commercial and industrial applications such as lift stations and below-grade sewage transfer. Switch not included
FRANKLIN ELECTRIC
This non-clog sewage ejector pump features a cast iron construction with a ductile iron impeller and horizontal discharge. It is powered by a 3 hp three-phase motor rated for 200 to 230V AC, delivering a maximum head of 42 ft. Designed for handling wastewater and effluent in commercial and industrial applications such as lift stations and below-grade sewage transfer. Switch not included

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first