We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FBR FNDP 100/2 TC SI - Burners & Combustion
FBRBurners & Combustion

FBR FNDP 100/2 TC SI

The FBR FNDP 100/2 TC SI is a two-stage heavy oil burner designed for industrial heating applications. It delivers thermal power from 687 to 1500 Mcal/h with a maximum fuel flow of 150 kg/h, operating on 3/N~400V…

SKU 3G-FBR-00275

Brand
FBR
Item
FNDP 100/2 TC SI
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
136 kg
stage
2 stages
fuel type
Heavy oil
nozzle mm
235
fan motor w
4
power kw max
1744
power kw min
798
flow kg h max
150
flow kg h min
70
ip protection
IP 40
noisiness dba
/
pump motor kw
0.55
electrical supply
3
power supply info
3/N~400V,
current absorption a
4.35
thermal power mcal h
687-1500
nominal electric power w
14
max combustion air temp c
60

Datasheet Content

HEAVY-OIL BURNERS TWO STAGES SK072066_B_en HEAVY-OIL฀BURNERS฀TWO฀STAGES FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2 Burners฀for฀heavy-oil฀two฀stages. Available฀in฀two฀versions: -FNP฀for฀fluid฀heavy฀oil฀up฀to฀3,5°E฀at฀50°C -FNDP฀for฀dense฀heavy฀oil฀up฀to฀20°E฀at฀50°C They฀are฀composed฀by:฀fan฀at฀high฀pressurisation,฀combustion฀head฀with฀adjustment฀at฀high฀efficiency฀and฀high฀flame฀ stability฀and฀hydraulic฀system฀of฀regulation฀combustive฀air฀on฀the฀two฀stages฀of฀flame. Compact฀overall฀dimensions฀and฀disposition฀rationalized฀of฀the฀components฀with฀accessibility฀facilitated฀for฀the฀ operations฀of฀setting฀and฀maintenance. Complete฀of฀nozzles,฀flexible฀pipes฀and฀line฀filter฀(for฀the฀models฀FNDP฀the฀line฀filter฀is฀electrically฀heated฀and฀ equipped฀with฀a฀thermostat). Complete฀of฀flange฀and฀gasket฀for฀installation฀on฀generator. FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2 HEAVY-OIL BURNERS TWO STAGES SK072066_B_en TECHNICAL฀DATA฀FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2 MODEL FNDP฀100/2 FNDP฀125/2 FNDP฀150/2 Flow min. - max. * [kg/h] 40-100 60-125 70-150 Thermal power min. - max. * [Mcal/h] 392-980 588-1225 687-1500 Thermal power min. - max. * [kW] 456-1139 684-1424 798-1744 Fuel: HEAVY-OIL MAX 20°E at 50°C Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Fan motor [kW] 2.2 3 4 Resistances [kW] 9 11 12 Power supply: 3/N~400V,฀1N~230V฀-฀50Hz Electric protection degree: IP฀40 Burner weight [kg] 100 130 136 *฀Reference฀conditions:฀Environment฀temperature฀20°C฀-฀Barometric฀pressure฀1013฀mbars฀-฀Altitude฀0฀metre฀(sea฀level). OPERATING฀RANGE฀DIAGRAM [mbar] 13 11 9 7 5 3 1 FNDP 100/2 FNDP 125/2 FNDP 150/2 -1 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 [kW] Fig. 1 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2 HEAVY-OIL BURNERS TWO STAGES SK072066_B_en DIMENSIONS [MM] Fig. 2 Dimensions฀FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2 MODEL A A max. B C D ØE TC TL I ØL M N FNDP฀100/2 656 1085 440 410 400 175 235 335 368 340 M12 190 FNDP฀125/2 820 1400 520 420 400 209 200 400 368 340 M14 230 FNDP฀150/2 820 1400 520 420 400 209 200 400 368 340 M14 230 FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2 HEAVY-OIL BURNERS TWO STAGES SK072066_B_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners two stages available in two versions: FNP for fluid heavy oil up to 3,5°E at 50°C or FNDP for dense heavy oil up tol 20°E at 50°C. DETAILED SPECIFICATION Light-oil burner two stages available in two versions: FNP for fluid heavy oil up to 3,5°E at 50°C or FNDP for dense heavy oil up tol 20°E at 50°C composed by: • Fan฀at฀high฀pressurisation; • Combustion฀head฀with฀adjustment฀at฀high฀performance฀and฀elevated฀flame฀stability; • Flange฀and฀insulating฀gasket฀for฀fixing฀at฀boiler; • Three-phase฀with฀neutral฀power฀supply; • Photodiode฀for฀flame฀detection; • IP฀40฀electric฀protection฀level; • Supports฀and฀tierods฀for฀burner฀extraction; • Easy฀extraction฀of฀combustion฀head฀without฀get฀off฀the฀burners฀by฀bolier. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive MAC; • 2014/68/EU (art.4, par.3) Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible฀hoses฀for฀connection; • Line฀filter฀ (for฀the฀models฀FNDP฀the฀line฀filter฀is฀electrically฀heated฀and฀equipped฀with฀a฀thermostat); • Isomart฀gasket; • Nozzles; • Flange฀with฀insulating฀gasket; • Burner฀nameplate; • Warranty; • Instruction฀handbook฀for฀installation,฀use฀and฀maintenance. OPTIONAL • Noise฀protection. The฀illustrations฀and฀data฀here฀shown฀are฀indicative.฀F.B.R.฀Bruciatori฀S.r.l.฀reserves฀the฀right฀to฀bring,฀without฀any฀obligation฀of฀warning,฀any฀changes฀that฀would฀be฀appropriate฀to฀the฀continuing฀development฀of฀their฀products. FNDP฀100/2฀-฀FNDP฀125/2฀-฀FNDP฀150/2
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR FNDP 100/2 TC SI is a two-stage heavy oil burner designed for industrial heating applications. It delivers thermal power from 687 to 1500 Mcal/h with a maximum fuel flow of 150 kg/h, operating on 3/N~400V electrical supply. Ideal for facilities requiring efficient heavy oil combustion with modulating capacity.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I order the FBR FNDP 100/2 TC SI burner in the Philippines?

Order from 3G Electric Philippines at www.3g-electric.com.ph. We deliver to Manila and Quezon City and handle all Bureau of Customs documentation and logistics. Lead time on request — contact our team for availability and PHP invoicing.

What is the thermal output range of the FNDP 100/2 TC SI?

The burner delivers thermal power from 687 to 1500 Mcal/h with a maximum fuel flow of 150 kg/h. It operates on 3/N~400V three-phase electrical supply and features two-stage modulating combustion for efficient heavy oil heating.

What type of heavy oil does the FNDP 100/2 TC SI handle?

The FNDP 100/2 TC SI is rated for dense heavy oil up to 20°E viscosity at 50°C. It features a 235 mm nozzle, weighs 136 kg, and includes 0.55 kW pump motor and 4 kW fan motor for reliable two-stage operation in industrial facilities.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FNDP 100/2 TL SI
FBR
FNDP 100/2 TL SI
FNDP 70/2 TC SI
FBR
FNDP 70/2 TC SI
FNDP 45/2 TC SI
FBR
FNDP 45/2 TC SI
FNDP 25/2 TC SI
FBR
FNDP 25/2 TC SI
FNDP 100/M TC SA
FBR
FNDP 100/M TC SA
FNDP 70/2 TL SI
FBR
FNDP 70/2 TL SI

More from FBR

View all FBR parts
FNDP 100/2 TC
FBR
FNDP 100/2 TC
FBR
FBR
FNDP 750/M TL MEC
FBR
FBR
FNDP 250/M TL MEC
FBR
FBR
FNDP 450/M TL MEC
FBR
FBR
FNDP 350/M TL MEC
FBR
FBR
FNDP 150/M TL
FNDP 125/2 TC
FBR
FNDP 125/2 TC
FBR
FBR
FNDP 190/M TL MEC