FBR FNDL 25 TC S

The FBR FNDL 25 TC S is a single-stage heavy oil burner delivering 142–285 kW thermal power with a 120 mm nozzle and 12.5–25 kg/h fuel flow. IP 44 rated and operating at 74 dBA, it suits industrial heating…

SKU 3G-FBR-00279

Brand
FBR
Item
FNDL 25 TC S
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FBR
Weight
41 kg
stage
Single stage
fuel type
Heavy oil
nozzle mm
120
fan motor w
0.55
power kw max
285
power kw min
142
flow kg h max
25
flow kg h min
12.5
ip protection
IP 44
noisiness dba
74
electrical supply
3
power supply info
3/N~400V, 1N~230V-50Hz
current absorption a
0.2
thermal power mcal h
122.5-245
nominal electric power w
4.8
max combustion air temp c
60

Datasheet Content

HEAVY-OIL BURNERS ONE STAGE SK072015_A_en FNDL 8 - FNDL 16 - FNDL 25 Burners for heavy-oil single stage with: fan at high pressurisation, combustion head with adjustment at high efficiency and high flame stability. Disposition rationalized of the components with accessibility facilitated for operations of setting and maintenance. Complete of flange and gasket for installation on generator, nozzle, flexible pipes, line filter electrically heated and equipped with a thermostat. FNDL 8 - FNDL 16 - FNDL 25 HEAVY-OIL BURNERS ONE STAGE SK072015_A_en TECHNICAL DATA FNDL 8 - FNDL 16 - FNDL 25 MODEL FNDL 8 FNDL 16 FNDL 25 Flow min. - max. * [kg/h] 5-8 7-16 12.5-25 Thermal power min. - max. * [Mcal/h] 49-78.4 68.6-156.8 122.5-245 Thermal power min. - max. * [kW] 57-91 .1 79.8-182 142- 285 Fuel: HEAVY-OIL MAX 20°E at 50°C Intermitted working operation (min. 1 stop every 24 hours) one stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 1.7 2 4.8 Fan motor [kW] 0.25 0.25 0.55 Resistances [kW] 1.2 1.5 2.4 Fan motor current absorption [A] 8 10 18.2 Auxiliary current absorption [A] 0.14 0.14 0.2 Power supply: 1N~230V-50Hz 3/N~400V, 1N~230V-50Hz Electric protection degree: IP 44 Noisiness ** min-max [dBA] 69 69 74 Burner weight [kg] 35 36 41 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). OPERATING RANGE DIAGRAM [mbar] 3.5 3 2.5 2 1.5 1 0.5 FNDL 8 FNDL 16 FNDL 25 0 -0.5 50 100 150 200 250 300 [kW] Fig. 1 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FNDL 8 - FNDL 16 - FNDL 25 HEAVY-OIL BURNERS ONE STAGE SK072015_A_en DIMENSIONS [MM] Fig. 2 Dimensions FNDL 8 - FNDL 16 - FNDL 25 MODEL A B C D E F G H I L FNDL 8 253 294 107 410 251 102 120 180 226 10 FNDL 16 253 294 107 410 251 102 120 180 226 10 FNDL 25 255 294 130 410 251 102 140 180 226 10 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** FNDL 8 mm 110 230 FNDL 16 mm 110 230 FNDL 25 mm 120 240 ** For different flame lengths, please contact our Technical-Sales Department. FNDL 8 - FNDL 16 - FNDL 25 HEAVY-OIL BURNERS ONE STAGE SK072015_A_en PRODUCT SPECIFICATION SHORT DESCRIPTION Heavy-oil burners single stage. DETAILED SPECIFICATION Heavy-oil burners single stage composed by: • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability; • Flange and insulating gasket for fixing at boiler; • Photodiode for flame detection; • IP 44 electric protection level; CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive MAC; • 2014/68/EU (art.4, par.3) Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter electrically heated and equipped with a thermostat; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. FNDL 8 - FNDL 16 - FNDL 25
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR FNDL 25 TC S is a single-stage heavy oil burner delivering 142–285 kW thermal power with a 120 mm nozzle and 12.5–25 kg/h fuel flow. IP 44 rated and operating at 74 dBA, it suits industrial heating applications requiring reliable heavy oil combustion.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the FBR FNDL 25 TC S heavy oil burner in the Philippines?

3G Electric Philippines supplies the FBR FNDL 25 TC S with delivery to Manila and Quezon City. We handle all Bureau of Customs documentation and logistics. Contact us for lead time and PHP pricing on this 142–285 kW heavy oil burner.

What is the lead time for the FBR FNDL 25 TC S?

Lead time on request. 3G Electric sources the FBR FNDL 25 TC S available to order and manages all customs clearance to the Philippines. Delivery timeframe depends on current demand—contact our team for a firm quote.

What are the fuel flow and power specifications of the FNDL 25 TC S?

The FBR FNDL 25 TC S delivers 142–285 kW thermal power with a fuel flow range of 12.5–25 kg/h. It features a 120 mm nozzle, IP 44 protection, and operates at 74 dBA. Ideal for industrial heating systems requiring single-stage heavy oil combustion.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FNDL 25 TL S
FBR
FNDL 25 TL S
FNDP 25/2 TC SI
FBR
FNDP 25/2 TC SI
FNDP 25/2 TL SI
FBR
FNDP 25/2 TL SI
FNDL 8 TC S
FBR
FNDL 8 TC S
FNDL 16 TC S
FBR
FNDL 16 TC S
FNDP 45/2 TC SI
FBR
FNDP 45/2 TC SI

More from FBR

View all FBR parts
FNDP 100/2 TC
FBR
FNDP 100/2 TC
FBR
FBR
FNDP 750/M TL MEC
FBR
FBR
FNDP 250/M TL MEC
FBR
FBR
FNDP 450/M TL MEC
FBR
FBR
FNDP 350/M TL MEC
FBR
FBR
FNDP 150/M TL
FNDP 125/2 TC
FBR
FNDP 125/2 TC
FBR
FBR
FNDP 190/M TL MEC