We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FLUKE FLUKE-51-2/CWG Thermocouple Meter with Cabled Data Output - Thermocouple Meters with Cabled Data Output
FLUKEThermocouple Meters with Cabled Data Output

FLUKE FLUKE-51-2/CWG Thermocouple Meter with Cabled Data Output

The FLUKE Thermocouple Thermometer (MPN FLUKE-51-2/CWG) is a thermocouple meter with cabled data output, offering a temperature range of -418°F to 1999°F. It supports Type E, Type J, Type K, and Type T thermocouples…

SKU 3G-OTH-177038

Also listed as: FLUKE512CWG · FLUKE 51 2 CWG · FLUKE-51-2-CWG

Brand
FLUKE
Item
FLUKE-51-2/CWG Thermocouple Meter with Cabled Data Output
Category
Thermocouple Meters with Cabled Data Output
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FLUKE
Manufacturer Part Number
FLUKE-51-2/CWG
Type
For Type E/Type J/Type K/Type T Thermocouple Type
Accuracy
±0.05 % + 0.3 °C
Testing Functions
Average Temperature

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE Thermocouple Thermometer (MPN FLUKE-51-2/CWG) is a thermocouple meter with cabled data output, offering a temperature range of -418°F to 1999°F. It supports Type E, Type J, Type K, and Type T thermocouples, with an accuracy of ±0.05 % + 0.3 °C. The device includes an Average Temperature testing function.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the FLUKE Thermocouple Thermometer used for?

The FLUKE Thermocouple Thermometer (MPN FLUKE-51-2/CWG) measures temperature across a range of -418°F to 1999°F using Type E, J, K, or T thermocouples. It is used in industrial maintenance, HVAC, and process control for accurate temperature readings and includes an Average Temperature testing function.

What are the specifications of the FLUKE-51-2/CWG?

The FLUKE-51-2/CWG is a thermocouple meter with cabled data output. It supports Type E, J, K, and T thermocouples, has a temperature range of -418°F to 1999°F, and an accuracy of ±0.05 % + 0.3 °C. Testing functions include Average Temperature.

Where to buy the FLUKE Thermocouple Thermometer worldwide?

3G Electric supplies the FLUKE Thermocouple Thermometer (FLUKE-51-2/CWG) worldwide. As a global industrial solutions provider, we handle logistics, customs, and delivery to your location. Contact us to source this instrument for your facility.

How to select the right thermocouple type for the FLUKE-51-2/CWG?

Select the thermocouple type (E, J, K, or T) based on your temperature range and environment. For general industrial use, Type K is common. The FLUKE-51-2/CWG accepts all four types, so match the probe to your application's temperature and material compatibility.

Used in

Common applications for FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments

FLUKE Products

3G Electric supplies FLUKE thermocouple meters with cabled data output. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Two-channel thermocouple thermometer measuring from -328°F to 4,199°F. Accuracy ±0.24 °C for Type J, K, L, and M thermocouples. RS-232 interface enables cabled data output for recording and analysis. Suitable for temperature monitoring in industrial, HVAC, and laboratory settings
FLUKE
Two-channel thermocouple thermometer measuring from -328°F to 4,199°F. Accuracy ±0.24 °C for Type J, K, L, and M thermocouples. RS-232 interface enables cabled data output for recording and analysis. Suitable for temperature monitoring in industrial, HVAC, and laboratory settings
Two-channel thermometer with cabled data output via RS-232. Accepts Type J, K, L, and M thermocouples. Measures from -328°F to 4,199°F (primary range) and -328°F to 1,832°F (secondary range) with ±0.24 °C accuracy. Suitable for industrial process control, HVAC, and laboratory temperature monitoring
FLUKE
Two-channel thermometer with cabled data output via RS-232. Accepts Type J, K, L, and M thermocouples. Measures from -328°F to 4,199°F (primary range) and -328°F to 1,832°F (secondary range) with ±0.24 °C accuracy. Suitable for industrial process control, HVAC, and laboratory temperature monitoring
FLUKE FLK-T3000FC is a thermocouple meter for Type K thermocouples, measuring temperatures from -328°F to 2,500°F with ±0.5% + 0.5°C accuracy. It features Min/Max temperature testing functions and Wi-Fi for wireless data output. Suitable for industrial maintenance, HVAC diagnostics, and process monitoring
FLUKE
FLUKE FLK-T3000FC is a thermocouple meter for Type K thermocouples, measuring temperatures from -328°F to 2,500°F with ±0.5% + 0.5°C accuracy. It features Min/Max temperature testing functions and Wi-Fi for wireless data output. Suitable for industrial maintenance, HVAC diagnostics, and process monitoring
This calibrator furnace provides a stable temperature reference from 150°C to 1200°C with ±0.5°C stability. It accepts Type E, J, K, and T thermocouples and 4-wire RTDs with a 1/4 in stem diameter. Used for calibrating temperature sensors in industrial process control and maintenance environments
FLUKE
This calibrator furnace provides a stable temperature reference from 150°C to 1200°C with ±0.5°C stability. It accepts Type E, J, K, and T thermocouples and 4-wire RTDs with a 1/4 in stem diameter. Used for calibrating temperature sensors in industrial process control and maintenance environments
This calibrator furnace provides a stable temperature reference for calibrating Type E, J, K, and T thermocouples and 3-wire RTDs. It accommodates up to six probes with a stem diameter of 1/4 in and offers stability of +/-0.5°C. Typical applications include verification of temperature sensors in industrial process control and laboratory environments
FLUKE
This calibrator furnace provides a stable temperature reference for calibrating Type E, J, K, and T thermocouples and 3-wire RTDs. It accommodates up to six probes with a stem diameter of 1/4 in and offers stability of +/-0.5°C. Typical applications include verification of temperature sensors in industrial process control and laboratory environments

More from FLUKE

View all FLUKE parts
Thermocouple meter with cabled data output for use with Type E, J, K, and T thermocouples. Measures temperature from -418°F to 1999°F with accuracy of ±0.05 % + 0.3 °C. Features differential temperature testing function. Suitable for temperature measurement and comparison in industrial, HVAC, and process control applications
FLUKE
Thermocouple meter with cabled data output for use with Type E, J, K, and T thermocouples. Measures temperature from -418°F to 1999°F with accuracy of ±0.05 % + 0.3 °C. Features differential temperature testing function. Suitable for temperature measurement and comparison in industrial, HVAC, and process control applications
Two-channel thermocouple meter with USB data output for logging average temperature measurements. Accuracy of ±0.05% + 0.3°C over a range of -418°F to 1999°F. Suitable for field or laboratory temperature monitoring in industrial maintenance, HVAC, and process control applications
FLUKE
Two-channel thermocouple meter with USB data output for logging average temperature measurements. Accuracy of ±0.05% + 0.3°C over a range of -418°F to 1999°F. Suitable for field or laboratory temperature monitoring in industrial maintenance, HVAC, and process control applications
This thermocouple meter supports Type E, J, K, and T thermocouples, measuring temperatures from -418°F to 1999°F with an accuracy of ±0.05 % + 0.3 °C. It features differential temperature testing and cabled data output for recording and analysis. Suitable for industrial maintenance, HVAC, and process control applications
FLUKE
This thermocouple meter supports Type E, J, K, and T thermocouples, measuring temperatures from -418°F to 1999°F with an accuracy of ±0.05 % + 0.3 °C. It features differential temperature testing and cabled data output for recording and analysis. Suitable for industrial maintenance, HVAC, and process control applications
Dual-channel thermocouple meter with ±0.05% + 0.3 °C accuracy, USB connectivity for data output, and Min/Max temperature testing functions. Suitable for industrial temperature monitoring applications requiring two-channel measurement and data logging
FLUKE
Dual-channel thermocouple meter with ±0.05% + 0.3 °C accuracy, USB connectivity for data output, and Min/Max temperature testing functions. Suitable for industrial temperature monitoring applications requiring two-channel measurement and data logging
Thermocouple meter with cabled data output for Type E, J, K, and T thermocouples. Accuracy ±0.05 % + 0.3 °C. Includes Average Temperature testing function. Used for precision temperature measurement in industrial, HVAC, and laboratory applications
FLUKE
Thermocouple meter with cabled data output for Type E, J, K, and T thermocouples. Accuracy ±0.05 % + 0.3 °C. Includes Average Temperature testing function. Used for precision temperature measurement in industrial, HVAC, and laboratory applications
Two-channel thermocouple meter with USB connectivity for data output. Accuracy ±0.05% + 0.3°C. Supports differential temperature measurement for comparing two points. Suitable for temperature monitoring in industrial, HVAC, and laboratory settings
FLUKE
Two-channel thermocouple meter with USB connectivity for data output. Accuracy ±0.05% + 0.3°C. Supports differential temperature measurement for comparing two points. Suitable for temperature monitoring in industrial, HVAC, and laboratory settings
Two-channel thermocouple meter with USB connectivity for cabled data output. Measures temperature from -418°F to 1999°F with accuracy of ±0.05% + 0.3°C. Supports differential temperature testing for comparing two inputs. Suitable for industrial maintenance, HVAC, and laboratory temperature measurement applications
FLUKE
Two-channel thermocouple meter with USB connectivity for cabled data output. Measures temperature from -418°F to 1999°F with accuracy of ±0.05% + 0.3°C. Supports differential temperature testing for comparing two inputs. Suitable for industrial maintenance, HVAC, and laboratory temperature measurement applications