We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FLUKE Infrared Thermometer: FLK-568 EX/ETL, Min Temp, Adj @ 0.10 to 1.00, Intrinsically Safe - Intrinsically Safe Infrared Thermometers
FLUKEIntrinsically Safe Infrared Thermometers

FLUKE Infrared Thermometer: FLK-568 EX/ETL, Min Temp, Adj @ 0.10 to 1.00, Intrinsically Safe

The FLUKE FLK-568 EX/ETL is an intrinsically safe infrared thermometer designed for hazardous environments, meeting Class I Div. 1 and Div. 2 or Zone 1 and 2 certifications per ATEX/IECEx standards. It measures…

SKU 3G-OTH-179661

Also listed as: FLK568EXETL · FLK 568 EX ETL · FLK-568-EX-ETL

Brand
FLUKE
Item
Infrared Thermometer: FLK-568 EX/ETL, Min Temp, Adj @ 0.10 to 1.00, Intrinsically Safe
Category
Intrinsically Safe Infrared Thermometers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FLUKE
Manufacturer Part Number
FLK-568 EX/ETL
Type
Min Temp, Adj @ 0.10 to 1.00, Intrinsically Safe, USB
Features
Meets Intrinsically Safe Certifications in Class I Div. 1 and Div. 2 or Zone 1 and 2 Hazardous Environments
Standards
ATEX/IECEx
Alert Type
Sound
Accuracy °F
±1.0% of Reading or ±2.0° Whichever is Greater
Data Logging
Yes
Resolution °F
0.1°F
Interface - NEW
USB
Max. Emissivity
1.00
Min. Emissivity
0.10
Body Style - NEW
Compact
Testing Functions
Minimum Temperature
Temperature Alerts
Low Temperature
Mounting Style - NEW
Tripod
Intrinsic Safety - NEW
Intrinsically Safe
Includes Work Light - NEW
Work Light Included
Max. Temperature Measured
Over 1202° F
Min. Temperature Measured
-40°
Digital Display Screen Type
LCD
Calibration Certificate Type
Not Certified

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE FLK-568 EX/ETL is an intrinsically safe infrared thermometer designed for hazardous environments, meeting Class I Div. 1 and Div. 2 or Zone 1 and 2 certifications per ATEX/IECEx standards. It measures temperatures from -40°F to over 1202°F with an accuracy of ±1.0% of reading or ±2.0°F (whichever is greater) and a resolution of 0.1°F. Features include adjustable emissivity from 0.10 to 1.00, low-temperature alerts, minimum temperature testing, USB interface, tripod mounting, and an integrated work light.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the FLUKE FLK-568 EX/ETL infrared thermometer used for?

The FLUKE FLK-568 EX/ETL is used for non-contact temperature measurement in hazardous environments such as oil refineries, chemical plants, and gas facilities. It is intrinsically safe per ATEX/IECEx standards for Class I Div. 1 and Div. 2 or Zone 1 and 2 areas, enabling safe monitoring of equipment and processes.

What are the specifications of the FLUKE FLK-568 EX/ETL?

The FLUKE FLK-568 EX/ETL measures temperatures from -40°F to over 1202°F with ±1.0% accuracy or ±2.0°F, resolution 0.1°F. It features adjustable emissivity from 0.10 to 1.00, low-temperature alerts, minimum temperature testing, USB interface, tripod mounting, and meets ATEX/IECEx intrinsic safety certifications.

Where to buy the FLUKE FLK-568 EX/ETL worldwide?

3G Electric supplies the FLUKE FLK-568 EX/ETL worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time; we source and deliver this intrinsically safe thermometer to any country.

How to select the right emissivity for the FLUKE FLK-568 EX/ETL?

To select emissivity on the FLUKE FLK-568 EX/ETL, adjust the setting between 0.10 and 1.00 to match the target material's surface properties. For shiny metals, use lower values (e.g., 0.30); for non-metals like painted surfaces, use higher values (e.g., 0.95). Consult material emissivity tables for accuracy.

Used in

Common applications for FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments

FLUKE Products

3G Electric supplies FLUKE intrinsically safe infrared thermometers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
The FLUKE-572-2/CWG is a full-size infrared thermometer for harsh environments, measuring temperatures from -22°F to over 1202°F with ±1.0% or ±2.0°F accuracy and 0.1°F resolution. It features adjustable emissivity (0.10 to 1.00), Avg/Difference/Max Temp/Min Temp modes, a Class 2 laser, work light, tripod mount, USB connectivity, and audible alerts. Suitable for industrial maintenance, electrical troubleshooting, and HVAC applications
FLUKE
The FLUKE-572-2/CWG is a full-size infrared thermometer for harsh environments, measuring temperatures from -22°F to over 1202°F with ±1.0% or ±2.0°F accuracy and 0.1°F resolution. It features adjustable emissivity (0.10 to 1.00), Avg/Difference/Max Temp/Min Temp modes, a Class 2 laser, work light, tripod mount, USB connectivity, and audible alerts. Suitable for industrial maintenance, electrical troubleshooting, and HVAC applications
The FLUKE-572-2 is a full-size infrared thermometer designed for non-contact temperature measurement in harsh industrial environments. It features a digital LCD display, adjustable emissivity from 0.10 to 1.00, and supports Average, Difference, Max, and Min temperature modes. With USB connectivity and a tripod mount, it is suitable for plant maintenance, HVAC, and electrical troubleshooting where contact probes are impractical
FLUKE
The FLUKE-572-2 is a full-size infrared thermometer designed for non-contact temperature measurement in harsh industrial environments. It features a digital LCD display, adjustable emissivity from 0.10 to 1.00, and supports Average, Difference, Max, and Min temperature modes. With USB connectivity and a tripod mount, it is suitable for plant maintenance, HVAC, and electrical troubleshooting where contact probes are impractical
Full-size infrared thermometer with LCD display, measuring -4°F to 1202°F with ±2.0% accuracy. Features 532:1 distance-to-spot ratio, adjustable emissivity (0.10 to 1.00), Difference testing function, data logging via USB, and built-in work light. Rated for 2-meter drop test and complies with FCC Part 5. Suitable for non-contact temperature measurement in industrial maintenance, electrical troubleshooting, and HVAC applications
FLUKE
Full-size infrared thermometer with LCD display, measuring -4°F to 1202°F with ±2.0% accuracy. Features 532:1 distance-to-spot ratio, adjustable emissivity (0.10 to 1.00), Difference testing function, data logging via USB, and built-in work light. Rated for 2-meter drop test and complies with FCC Part 5. Suitable for non-contact temperature measurement in industrial maintenance, electrical troubleshooting, and HVAC applications
Intrinsically safe compact reference temperature calibrator with a measurement range of -58°F to 320°F / -50°C to 160°C. Features a 14-second response time and a 229 mm stem length. NIST Traceable. Used for precise temperature calibration in industrial environments
FLUKE
Intrinsically safe compact reference temperature calibrator with a measurement range of -58°F to 320°F / -50°C to 160°C. Features a 14-second response time and a 229 mm stem length. NIST Traceable. Used for precise temperature calibration in industrial environments
Intrinsically safe compact reference temperature calibrator with a measurement range of -58°F to 320°F (-50°C to 160°C). Features a 21-second response time and 305 mm stem length. NIST traceable. Used for verifying and adjusting temperature sensors and instruments in industrial environments
FLUKE
Intrinsically safe compact reference temperature calibrator with a measurement range of -58°F to 320°F (-50°C to 160°C). Features a 21-second response time and 305 mm stem length. NIST traceable. Used for verifying and adjusting temperature sensors and instruments in industrial environments
Intrinsically safe compact reference temperature calibrator with a measurement range of -58°F to 320°F / -50°C to 160°C. Features a 508 mm stem length and 21-second response time. NIST Traceable. Used for calibrating temperature sensors, transmitters, and thermostats in industrial process control and HVAC applications
FLUKE
Intrinsically safe compact reference temperature calibrator with a measurement range of -58°F to 320°F / -50°C to 160°C. Features a 508 mm stem length and 21-second response time. NIST Traceable. Used for calibrating temperature sensors, transmitters, and thermostats in industrial process control and HVAC applications

More from FLUKE

View all FLUKE parts