We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FLUKE CALIBRATION Single-Block Drywell Calibrator - Single-Block Drywell Calibrators with Adjustable Setpoints
FLUKE CALIBRATIONSingle-Block Drywell Calibrators with Adjustable Setpoints

FLUKE CALIBRATION Single-Block Drywell Calibrator

The FLUKE CALIBRATION Drywall Temperature Calibrator (MPN 9100S-D-156) is a single-block drywell calibrator with adjustable setpoints, covering a range of 14°F to 707°F (-10°C to 375°C). It offers stability of…

SKU 3G-OTH-178559

Also listed as: 9100SD156 · 9100S D 156

Brand
FLUKE CALIBRATION
Item
Single-Block Drywell Calibrator
Category
Single-Block Drywell Calibrators with Adjustable Setpoints
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FLUKE CALIBRATION
Manufacturer Part Number
9100S-D-156
Type
/-10°C to 375°C, For 1.6 mm Stem Dia
Stability
+/-0.05 °C at 0 °C
For Stem Diameter
1.6 mm

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE CALIBRATION Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE CALIBRATION Drywall Temperature Calibrator (MPN 9100S-D-156) is a single-block drywell calibrator with adjustable setpoints, covering a range of 14°F to 707°F (-10°C to 375°C). It offers stability of +/-0.05 °C at 0 °C and is designed for stem diameters of 1.6 mm. This unit provides a compact solution for temperature calibration in industrial settings.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the FLUKE CALIBRATION 9100S-D-156 drywell calibrator used for?

The FLUKE CALIBRATION 9100S-D-156 is a single-block drywell temperature calibrator used to verify and adjust temperature sensors and probes in industrial settings. It covers -10°C to 375°C with stability of +/-0.05 °C at 0 °C, making it suitable for calibration labs and maintenance departments.

What are the specifications of the FLUKE CALIBRATION 9100S-D-156?

The FLUKE CALIBRATION 9100S-D-156 drywell calibrator has a temperature range of -10°C to 375°C (14°F to 707°F), stability of +/-0.05 °C at 0 °C, and accepts probes with a 1.6 mm stem diameter. It is a single-block unit with adjustable setpoints, ideal for precise field calibration.

Where to buy the FLUKE CALIBRATION 9100S-D-156 worldwide?

3G Electric supplies the FLUKE CALIBRATION 9100S-D-156 drywell calibrator to customers worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact our team for a quote and lead time on this precision temperature calibration instrument.

How to maintain a FLUKE CALIBRATION drywell calibrator?

To maintain the FLUKE CALIBRATION 9100S-D-156, keep the drywell insert clean and free of debris. Allow the unit to cool before cleaning. Periodically verify calibration against a reference standard. Store in a dry environment when not in use. Refer to the manufacturer's manual for detailed procedures.

Used in

Common applications for FLUKE CALIBRATION
Process control calibration — Fluke Calibration drywell calibrators (e.g., 9100S-D-156) for temperature sensor verification in chemical plants.
Pressure transmitter testing — Fluke Calibration pneumatic test pump kits (e.g., 700HPPK-NPT) for calibrating gauges in oil and gas facilities.
Hydraulic system maintenance — Fluke Calibration deadweight testers (e.g., P5510/14B-2700G) for pressure standard checks in hydraulic power units.
Temperature probe validation — Fluke Calibration secondary probes (e.g., 5615-12-P) for RTD calibration in pharmaceutical manufacturing.
Field service calibration — Fluke Calibration pneumatic comparison test pumps (e.g., 700HPM manifold) for on-site pressure calibration in utility plants.

FLUKE CALIBRATION Products

3G Electric supplies FLUKE CALIBRATION single-block drywell calibrators with adjustable setpoints. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range -25°C to 140°C (-13°F to 284°F) with stability ±0.04°C at 140°C. Accepts stem diameters of 1/16 in. Suitable for verifying thermocouples, RTDs, and thermistors in HVAC, industrial process control, and building diagnostics
FLUKE
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range -25°C to 140°C (-13°F to 284°F) with stability ±0.04°C at 140°C. Accepts stem diameters of 1/16 in. Suitable for verifying thermocouples, RTDs, and thermistors in HVAC, industrial process control, and building diagnostics
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range 35°C to 350°C (95°F to 662°F) with stability of ±0.03°C at 50°C. Accommodates two probes with 6 mm stem diameter
FLUKE
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range 35°C to 350°C (95°F to 662°F) with stability of ±0.03°C at 50°C. Accommodates two probes with 6 mm stem diameter
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range 95°F to 662°F (35°C to 350°C) with stability of ±0.03°C at 50°C. Accommodates up to six probes with 1/4 in stem diameter
FLUKE
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range 95°F to 662°F (35°C to 350°C) with stability of ±0.03°C at 50°C. Accommodates up to six probes with 1/4 in stem diameter
This single-block drywell calibrator provides adjustable setpoints over a range of 95°F to 662°F (35°C to 350°C). It offers stability of ±0.03°C at 50°C and accepts probes with stem diameters up to 1/2 in. Used for calibrating temperature sensors such as thermocouples, RTDs, and thermistors in industrial process control and HVAC applications
FLUKE
This single-block drywell calibrator provides adjustable setpoints over a range of 95°F to 662°F (35°C to 350°C). It offers stability of ±0.03°C at 50°C and accepts probes with stem diameters up to 1/2 in. Used for calibrating temperature sensors such as thermocouples, RTDs, and thermistors in industrial process control and HVAC applications
Single-block drywell calibrator with adjustable setpoints for verifying and adjusting temperature sensors. Temperature range -13°F to 284°F / -25°C to 140°C with stability of ±0.02°C at –25°C. Accommodates up to six probes with 1/4 in stem diameter
FLUKE
Single-block drywell calibrator with adjustable setpoints for verifying and adjusting temperature sensors. Temperature range -13°F to 284°F / -25°C to 140°C with stability of ±0.02°C at –25°C. Accommodates up to six probes with 1/4 in stem diameter
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range -13°F to 284°F / -25°C to 140°C with stability ±0.02°C at -25°C. Accommodates two 1/4-inch stem diameter probes
FLUKE
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range -13°F to 284°F / -25°C to 140°C with stability ±0.02°C at -25°C. Accommodates two 1/4-inch stem diameter probes

More from FLUKE CALIBRATION

View all FLUKE CALIBRATION parts
Single-block drywell calibrator with adjustable setpoints for temperature calibration of sensors and probes. Stability of ±0.05 °C at 0 °C. Accommodates stem diameter of 11.1 mm. Suitable for industrial and laboratory calibration tasks requiring precise temperature control
FLUKE CALIBRATION
Single-block drywell calibrator with adjustable setpoints for temperature calibration of sensors and probes. Stability of ±0.05 °C at 0 °C. Accommodates stem diameter of 11.1 mm. Suitable for industrial and laboratory calibration tasks requiring precise temperature control