We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FLUKE Fluke-753 Documenting Process Calibrator - Documenting Process Calibrators
FLUKEDocumenting Process Calibrators

FLUKE Fluke-753 Documenting Process Calibrator

The FLUKE Fluke-753 is a Documenting Process Calibrator with a basic DC accuracy of +/- 0.05% + 0.05V. It features an LCD display, USB interface, and IP52 rating, and includes a USB cable. The calibrator supports…

SKU 3G-OTH-174762

Also listed as: Fluke753 · Fluke 753

Brand
FLUKE
Item
Fluke-753 Documenting Process Calibrator
Part Number
Fluke-753
Category
Documenting Process Calibrators
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FLUKE
Manufacturer Part Number
Fluke-753
Type
Fluke-753, 0 mA – 22 mA, 1 kiloohm – 10 kiloohm
Includes
USB Cable
RTD Type
Pt100 (3926)
IP Rating
IP52
Interface
USB
Intrinsic Safety
Not Specified Intrinsically Safe
Basic DC Accuracy
+/- 0.05% + 0.05V
Thermocouple Type
XK
Digital Display Screen Type
LCD
Calibration Certificate Type
NIST

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE Fluke-753 is a Documenting Process Calibrator with a basic DC accuracy of +/- 0.05% + 0.05V. It features an LCD display, USB interface, and IP52 rating, and includes a USB cable. The calibrator supports Pt100 (3926) RTD and XK thermocouple types, and comes with a NIST calibration certificate.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the FLUKE Fluke-753 documenting process calibrator used for?

The FLUKE Fluke-753 is used to source, simulate, and measure process signals such as 0 mA – 22 mA current and 1 kΩ – 10 kΩ resistance. It is ideal for calibrating and documenting transmitters, valves, and other process instruments in industrial plants, refineries, and manufacturing facilities.

What are the specifications of the FLUKE Fluke-753?

The FLUKE Fluke-753 has a basic DC accuracy of ±0.05% + 0.05 V, an LCD display, USB interface, and IP52 rating. It supports Pt100 (3926) RTD and XK thermocouple types, includes a USB cable, and comes with a NIST calibration certificate. It is not specified as intrinsically safe.

Where to buy the FLUKE Fluke-753 worldwide?

You can source the FLUKE Fluke-753 from 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time; we provide the calibrator with a NIST certificate and USB cable.

How to select the right documenting process calibrator for your application?

When selecting a documenting process calibrator like the FLUKE Fluke-753, consider the required signal types (mA, RTD, thermocouple), accuracy (±0.05% + 0.05 V), and environmental rating (IP52). Ensure the calibrator supports your specific RTD (Pt100 3926) and thermocouple (XK) types, and includes documentation features for compliance.

Used in

Common applications for FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments
Not sure this is the right part? Photo-identify it

FLUKE Products

3G Electric supplies FLUKE documenting process calibrators. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
The FLUKE Fluke-725 is a multifunction calibrator that sources frequency and measures DC voltage, frequency, resistance, RTD (Pt100 393), and thermocouple type U. It sources 0 mA to 24 mA and features a basic DC accuracy of 0.02% + 2 counts. The unit includes test leads, an LCD with backlight, and a NIST calibration certificate. Typical applications include calibration and troubleshooting of process control loops in industrial environments
FLUKE
The FLUKE Fluke-725 is a multifunction calibrator that sources frequency and measures DC voltage, frequency, resistance, RTD (Pt100 393), and thermocouple type U. It sources 0 mA to 24 mA and features a basic DC accuracy of 0.02% + 2 counts. The unit includes test leads, an LCD with backlight, and a NIST calibration certificate. Typical applications include calibration and troubleshooting of process control loops in industrial environments
The FLUKE-726 is a precision multifunction calibrator that sources AC voltage and measures current from 0.001 mA to 24 mA. It supports HART communication protocol, simulates RTD (Pt100 392) and thermocouple (XK) signals, and features an LCD with backlight. Basic DC accuracy is ±0.01% + 2 mV. Includes alligator clips and NIST calibration certificate. Used for field calibration and verification of process instruments
FLUKE
The FLUKE-726 is a precision multifunction calibrator that sources AC voltage and measures current from 0.001 mA to 24 mA. It supports HART communication protocol, simulates RTD (Pt100 392) and thermocouple (XK) signals, and features an LCD with backlight. Basic DC accuracy is ±0.01% + 2 mV. Includes alligator clips and NIST calibration certificate. Used for field calibration and verification of process instruments
Standard process calibrator multimeter that sources resistance parameters and measures DC current. Features a wireless interface, LCD display, and CAT IV 600V safety rating. Includes test lead set. Basic DC accuracy 0.2% + 2 LSD (DC)
FLUKE
Standard process calibrator multimeter that sources resistance parameters and measures DC current. Features a wireless interface, LCD display, and CAT IV 600V safety rating. Includes test lead set. Basic DC accuracy 0.2% + 2 LSD (DC)
Multifunction calibrator for sourcing and measuring DC current, DC voltage, pressure, resistance, RTD, and thermocouple parameters. Supports HART communication protocol. Features basic DC accuracy of ±0.01% + 1 count, CAT II 300V safety rating, LCD with backlight, and RS-232 interface. Includes rugged case and NIST calibration certificate. Used for calibration and troubleshooting of process instruments in industrial environments
FLUKE
Multifunction calibrator for sourcing and measuring DC current, DC voltage, pressure, resistance, RTD, and thermocouple parameters. Supports HART communication protocol. Features basic DC accuracy of ±0.01% + 1 count, CAT II 300V safety rating, LCD with backlight, and RS-232 interface. Includes rugged case and NIST calibration certificate. Used for calibration and troubleshooting of process instruments in industrial environments
Calibration management software for multifunction calibrators supporting AC Volt, DC Volt, and Resist measurements with a current range of 0 mA to 24 mA. Features Basic DC Accuracy of +/- 0.05% + 5 Digits and connects via USB interface; USB cable included. Used in industrial maintenance and quality assurance for managing calibration data
FLUKE
Calibration management software for multifunction calibrators supporting AC Volt, DC Volt, and Resist measurements with a current range of 0 mA to 24 mA. Features Basic DC Accuracy of +/- 0.05% + 5 Digits and connects via USB interface; USB cable included. Used in industrial maintenance and quality assurance for managing calibration data
The FLUKE-789 is a standard process calibrator multimeter that sources resistance parameters and measures AC current, AC voltage, continuity, DC voltage, diodes, and frequency. It features a wireless interface, a basic DC accuracy of 0.2% + 2 LSD (DC), and a CAT IV 600V safety rating. The unit includes a safety-designed test lead set. Typical applications include troubleshooting and calibrating 4-20 mA loops and other field instruments in industrial process control systems
FLUKE
The FLUKE-789 is a standard process calibrator multimeter that sources resistance parameters and measures AC current, AC voltage, continuity, DC voltage, diodes, and frequency. It features a wireless interface, a basic DC accuracy of 0.2% + 2 LSD (DC), and a CAT IV 600V safety rating. The unit includes a safety-designed test lead set. Typical applications include troubleshooting and calibrating 4-20 mA loops and other field instruments in industrial process control systems

More from FLUKE

View all FLUKE parts
Documenting process calibrator with basic DC accuracy of ±0.05% + 0.05V, supporting HART communication and thermocouple type XK. Measures and sources 0 mA – 22 mA current. Includes USB cable, IP52 rating, and NIST calibration certificate. Used for calibrating and troubleshooting process instruments in industrial environments
FLUKE
Documenting process calibrator with basic DC accuracy of ±0.05% + 0.05V, supporting HART communication and thermocouple type XK. Measures and sources 0 mA – 22 mA current. Includes USB cable, IP52 rating, and NIST calibration certificate. Used for calibrating and troubleshooting process instruments in industrial environments
The FLUKE Fluke-754 is a documenting process calibrator that sources, simulates, and measures electrical signals for calibration and troubleshooting of process instrumentation. It supports HART communication protocol, measures 0 mA to 22 mA and 1 V to 15 V, and offers basic DC accuracy of ±0.05% + 0.05V. The unit includes an LCD display, USB interface, IP52 rating, carrying case, and NIST calibration certificate. It accommodates RTD type Pt500 (385) and thermocouple type XK
FLUKE
The FLUKE Fluke-754 is a documenting process calibrator that sources, simulates, and measures electrical signals for calibration and troubleshooting of process instrumentation. It supports HART communication protocol, measures 0 mA to 22 mA and 1 V to 15 V, and offers basic DC accuracy of ±0.05% + 0.05V. The unit includes an LCD display, USB interface, IP52 rating, carrying case, and NIST calibration certificate. It accommodates RTD type Pt500 (385) and thermocouple type XK
The FLUKE-754/FPC is a documenting process calibrator that sources DC voltage and supports HART communication. It offers a basic DC accuracy of ±0.05% + 0.05V, sources 0 mA to 22 mA and 1 V to 15 V, and includes a USB interface and battery charger. With an IP52 rating and NIST calibration certificate, it is suited for field or laboratory calibration of process instruments
FLUKE
The FLUKE-754/FPC is a documenting process calibrator that sources DC voltage and supports HART communication. It offers a basic DC accuracy of ±0.05% + 0.05V, sources 0 mA to 22 mA and 1 V to 15 V, and includes a USB interface and battery charger. With an IP52 rating and NIST calibration certificate, it is suited for field or laboratory calibration of process instruments