We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

FLUKE FLUKE-568 Infrared Thermometer with Contact Probe - Infrared Thermometers with Contact Probes
FLUKEInfrared Thermometers with Contact Probes

FLUKE FLUKE-568 Infrared Thermometer with Contact Probe

The FLUKE-568 is a full-size infrared thermometer with contact probe capability from FLUKE, featuring a Class II laser and an LCD display. It measures temperatures from -40°F to over 1202°F with an accuracy of ±1.0%…

SKU 3G-OTH-177078

Also listed as: FLUKE568 · FLUKE 568

Brand
FLUKE
Item
FLUKE-568 Infrared Thermometer with Contact Probe
Part Number
FLUKE-568
Category
Infrared Thermometers with Contact Probes
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

FLUKE
Manufacturer Part Number
FLUKE-568
Type
Min Temp, Adj @ 0.10 to 1.00, Full Size Thermometer Size
Features
Comes with a Conductive Case to Safely Carry the IR Thermometer Into Hazardous Areas
Standards
Class II Laser
Alert Type
Light
Accuracy °F
±1.0% of Reading or ±2.0° Whichever is Greater
Data Logging
Yes
Resolution °F
0.1°F
Interface - NEW
USB
Max. Emissivity
1.00
Min. Emissivity
0.10
Body Style - NEW
Full Size
Testing Functions
Minimum Temperature
Temperature Alerts
High Temperature
Mounting Style - NEW
Tripod
Intrinsic Safety - NEW
Not Specified Intrinsically Safe
Includes Work Light - NEW
Work Light Included
Max. Temperature Measured
Over 1202° F
Min. Temperature Measured
-40°
Digital Display Screen Type
LCD
Calibration Certificate Type
Not Certified

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE-568 is a full-size infrared thermometer with contact probe capability from FLUKE, featuring a Class II laser and an LCD display. It measures temperatures from -40°F to over 1202°F with an accuracy of ±1.0% of reading or ±2.0°F, whichever is greater, and a resolution of 0.1°F. The unit includes a conductive case for safe use in hazardous areas, a work light, USB interface, data logging, high-temperature alerts, and tripod mounting, with adjustable emissivity from 0.10 to 1.00.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the FLUKE-568 infrared thermometer used for?

The FLUKE-568 is used for non-contact temperature measurement in industrial maintenance, electrical troubleshooting, and hazardous environments. It features a conductive case for safe use in such areas, a Class II laser for targeting, and contact probe capability for verification. It is suitable for applications requiring high-temperature alerts and data logging.

What are the specifications of the FLUKE-568 infrared thermometer?

The FLUKE-568 measures temperatures from -40°F to over 1202°F with ±1.0% of reading or ±2.0°F accuracy, whichever is greater, and 0.1°F resolution. It has adjustable emissivity from 0.10 to 1.00, USB interface, data logging, high-temperature alerts, tripod mounting, and a Class II laser. It is not specified as intrinsically safe.

Where to buy the FLUKE-568 infrared thermometer worldwide?

You can source the FLUKE-568 infrared thermometer worldwide through 3G Electric, a global industrial equipment distributor established in 1990. We handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time; we provide competitive sourcing for this FLUKE model.

How to select the correct emissivity setting on the FLUKE-568?

To select the correct emissivity on the FLUKE-568, adjust the setting between 0.10 and 1.00 based on the target material's surface properties. For most painted or oxidized metals, start near 0.95. For shiny metals, use a lower value. Refer to FLUKE's emissivity reference guide for specific materials to ensure accurate readings.

Used in

Common applications for FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments
Not sure this is the right part? Photo-identify it

FLUKE Products

3G Electric supplies FLUKE infrared thermometers with contact probes. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Pocket-size infrared thermometer with Class II laser, measuring -40°F to 1202°F. Accuracy ±1.0% of reading or ±2.0°F, resolution 0.1°F. Adjustable emissivity 0.10 to 1.00, data logging, average function, low temperature alerts, tripod mount, and work light. LCD display
FLUKE
Pocket-size infrared thermometer with Class II laser, measuring -40°F to 1202°F. Accuracy ±1.0% of reading or ±2.0°F, resolution 0.1°F. Adjustable emissivity 0.10 to 1.00, data logging, average function, low temperature alerts, tripod mount, and work light. LCD display
Pocket-size infrared thermometer with Class II laser and LCD display. Measures -40°F to 1202°F with ±1.0% or ±2.0°F accuracy and 0.1°F resolution. Includes work light, data logging, low-temperature alert, and tripod mount. Supplied with NIST calibration certificate
FLUKE
Pocket-size infrared thermometer with Class II laser and LCD display. Measures -40°F to 1202°F with ±1.0% or ±2.0°F accuracy and 0.1°F resolution. Includes work light, data logging, low-temperature alert, and tripod mount. Supplied with NIST calibration certificate
Handheld infrared thermometer with contact probe for non-contact and contact temperature measurement. Features adjustable emissivity (0.01 to 1.00), data logging, and high-temperature alerts. Measures from -22°F to over 1202°F with ±1.8°F accuracy (32.0° to 212.0°). Includes work light and LCD display. Suitable for industrial maintenance, HVAC, and electrical troubleshooting
FLIR
Handheld infrared thermometer with contact probe for non-contact and contact temperature measurement. Features adjustable emissivity (0.01 to 1.00), data logging, and high-temperature alerts. Measures from -22°F to over 1202°F with ±1.8°F accuracy (32.0° to 212.0°). Includes work light and LCD display. Suitable for industrial maintenance, HVAC, and electrical troubleshooting
The FLUKE-572-2/CWG is a full-size infrared thermometer for harsh environments, measuring temperatures from -22°F to over 1202°F with ±1.0% or ±2.0°F accuracy and 0.1°F resolution. It features adjustable emissivity (0.10 to 1.00), Avg/Difference/Max Temp/Min Temp modes, a Class 2 laser, work light, tripod mount, USB connectivity, and audible alerts. Suitable for industrial maintenance, electrical troubleshooting, and HVAC applications
FLUKE
The FLUKE-572-2/CWG is a full-size infrared thermometer for harsh environments, measuring temperatures from -22°F to over 1202°F with ±1.0% or ±2.0°F accuracy and 0.1°F resolution. It features adjustable emissivity (0.10 to 1.00), Avg/Difference/Max Temp/Min Temp modes, a Class 2 laser, work light, tripod mount, USB connectivity, and audible alerts. Suitable for industrial maintenance, electrical troubleshooting, and HVAC applications
Handheld infrared thermometer with backlit LCD display, measuring from -22°F to 1202°F with accuracy of ±1.5% of reading or ±3.0°F (whichever is greater) and 0.2°F resolution. Features adjustable emissivity from 0.10 to 1.00, max/min/avg/difference temperature modes, low temperature alert, and integrated work light. IP40 rated, compliant with standards 61326-1 and EN 61326-2. Suitable for non-contact surface temperature measurement in industrial maintenance, HVAC, and electrical applications
FLUKE
Handheld infrared thermometer with backlit LCD display, measuring from -22°F to 1202°F with accuracy of ±1.5% of reading or ±3.0°F (whichever is greater) and 0.2°F resolution. Features adjustable emissivity from 0.10 to 1.00, max/min/avg/difference temperature modes, low temperature alert, and integrated work light. IP40 rated, compliant with standards 61326-1 and EN 61326-2. Suitable for non-contact surface temperature measurement in industrial maintenance, HVAC, and electrical applications
The FLUKE-572-2 is a full-size infrared thermometer designed for non-contact temperature measurement in harsh industrial environments. It features a digital LCD display, adjustable emissivity from 0.10 to 1.00, and supports Average, Difference, Max, and Min temperature modes. With USB connectivity and a tripod mount, it is suitable for plant maintenance, HVAC, and electrical troubleshooting where contact probes are impractical
FLUKE
The FLUKE-572-2 is a full-size infrared thermometer designed for non-contact temperature measurement in harsh industrial environments. It features a digital LCD display, adjustable emissivity from 0.10 to 1.00, and supports Average, Difference, Max, and Min temperature modes. With USB connectivity and a tripod mount, it is suitable for plant maintenance, HVAC, and electrical troubleshooting where contact probes are impractical

More from FLUKE

View all FLUKE parts
Full-size infrared thermometer with contact probe for both contact and non-contact temperature measurement from -40° to 1202°F. Features adjustable emissivity (0.30 to 0.95), Class II laser, difference testing function, backlit LCD display, and work light. Tripod-mountable. Accuracy ±1.0% of reading or ±2.0°F (whichever is greater below 32°F). Includes traceable calibration certificate with data
FLUKE
Full-size infrared thermometer with contact probe for both contact and non-contact temperature measurement from -40° to 1202°F. Features adjustable emissivity (0.30 to 0.95), Class II laser, difference testing function, backlit LCD display, and work light. Tripod-mountable. Accuracy ±1.0% of reading or ±2.0°F (whichever is greater below 32°F). Includes traceable calibration certificate with data
Combines contact and non-contact temperature measurement in one instrument. Measures from -40°F to over 1202°F with ±1.0% of reading or ±2.0°F accuracy and 0.1°F resolution. Features Class II laser, USB interface, data logging, high-temperature alerts, difference testing function, LCD display, work light, and tripod mount. Includes NIST calibration certificate
FLUKE
Combines contact and non-contact temperature measurement in one instrument. Measures from -40°F to over 1202°F with ±1.0% of reading or ±2.0°F accuracy and 0.1°F resolution. Features Class II laser, USB interface, data logging, high-temperature alerts, difference testing function, LCD display, work light, and tripod mount. Includes NIST calibration certificate
Full-size infrared thermometer with contact probe for combined non-contact and contact temperature measurements. Features a fabric hook-and-loop fastener pipe probe for superheat, sub-cooling, and other contact and ambient measurements. Measures from -40°F to 1202°F with ±1.0% or ±2.0°F accuracy (below 32°F), 0.1°F resolution, Class II laser, backlit LCD, work light, and tripod mount. Includes minimum temperature testing function
FLUKE
Full-size infrared thermometer with contact probe for combined non-contact and contact temperature measurements. Features a fabric hook-and-loop fastener pipe probe for superheat, sub-cooling, and other contact and ambient measurements. Measures from -40°F to 1202°F with ±1.0% or ±2.0°F accuracy (below 32°F), 0.1°F resolution, Class II laser, backlit LCD, work light, and tripod mount. Includes minimum temperature testing function