We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Fireye NX6220 and NX6330 12-Key Keypad Display - Touchscreens & Displays
FireyeTouchscreens & Displays

Fireye NX6220 and NX6330 12-Key Keypad Display

The Fireye 3G-OTH-02838 and NX6330 are 12-key keypad displays from the Touchscreens & Displays category. These models are CE and UL Listed. The product is available under SKU 3G-OTH-02838, and the series also…

SKU 3G-OTH-02838

Also listed as: NX 6220 · NX-6220

Brand
Fireye
Item
NX6220 and NX6330 12-Key Keypad Display
Category
Touchscreens & Displays
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Fireye
Models
NX6220, NX6330, NX6100, PPC6000
Category
Touchscreens & Displays
Approvals
CE, UL Listed

Datasheet Content

[{"filename":"NXD-6301-NX6220_and_NX6330_12-Key_Keypad_Display_English_2023_06_02.pdf","text":"NXD-6301\n 3G-OTH-02838, NX6330\n February 6, 2023\n\n\n\n NEXUS 3G-OTH-02838\n and NX6330\n 12-Key\n KEYPAD\n DISPLAY\n\n\nINTRODUCTION:\n\n The Fireye 3G-OTH-02838 or NX6330 (with Ethernet) OLED (Organic LED) 12 key keypad\n displays provide an easy to read, bright operator interface for operation and\n commissioning of Fireye NX6100 or PPC6000* series control. The addition of four multi-\n function soft keys, make commissioning quicker and easier. Once in commissioning\n mode, these keys group related options, such as all servomotor options, together for\n convenience, minimizing the risk of skipping options that are related but in different\n areas of the program.\n\n Two models are available: 3G-OTH-02838 (basic display with USB port) and NX6330 (USB and\n Ethernet port). Both displays include complete commissioning back up as well as three\n user defined relays. English, French and Spanish languages are supported and can\n easily be selected from a list of available languages stored within the display. Other\n languages may be added from time to time, consult the factory for availability.\n\n The NX6330 Display also includes a choice of MODbus TC/PIP or BACnet integration\n into Building Automation Systems (BAS). See Fireye Bulletin MOD-6001 for the\n appropriate register point lists.\n\n The tactile membrane keypad provides a “click” feedback for positive key stroke entry.\n The lithium-ion battery maintains the commissioned backup, clock, calendar, and event\n log function in the event of power loss.\n\n * When used with the Fireye PPC6000, the Fuel key will have no function as fuel\n selection is performed externally to the PPC6000.\n\n\n\n\n© 2023 Carrier 1\n\f Inside this bulletin:\n\n\nContents\n1. OLED (Organic LED) Display & Keypad option ........................................................................... 3\n 1.1 System Overview / Main Screen .............................................................................................. 5\n2. Engineers Keys ............................................................................................................................ 6\n 2.1 Fault Log .................................................................................................................................. 7\n3. Fuel (Profile) Selection ................................................................................................................. 8\n4. On/Off Mode Selection ................................................................................................................. 9\n5. Data Key Mode ........................................................................................................................... 10\n 5.1 Profile Review Mode .............................................................................................................. 11\n 5.2 Hours Run Mode .................................................................................................................... 12\n6. Commissioning/Profile Adjust .................................................................................................... 13\n7. Setup Screen .............................................................................................................................. 14\n 7.1 Ethernet Setup Mode (Figure A) ............................................................................................ 15\n 7.2 Ethernet Setup Mode (Figure B) ........................................................................................... 15\n8. How to Commission using the Text Display............................................................................... 16\n 8.1 Going into Commission Ratio mode ...................................................................................... 16\n 8.2 Using the Option Set mode .................................................................................................... 17\n9. Backup and Restore From USB ................................................................................................. 18\n 9.1 Saving a Backup to USB........................................................................................................ 18\n 9.2 Viewing the contents of the USB drive .................................................................................. 19\n 9.3 Restoring a Backup from USB ............................................................................................... 20\n10. Specification for the FIREYE 3G-OTH-02838 or NX6330 12 key display ............................................ 21\n11. FIREYE 3G-OTH-02838, NX6330 MOUNTING DETAILS .................................................................... 22\n12. Electrical Connections...............................................................................................................23\n\n\n\n\n© 2023 Carrier 2\n\f1. OLED (Organic LED) Display & Keypad option\nThe OLED display supports plain text information in a variety of formats. This display is used for\nsetting up the controller parameters and operating the boiler. The keypad is a membrane construction\nwith tactile keys (you can feel the ‘click’) that gives positive feedback of the actuation. This unit\nincludes a lithium battery for the clock / calendar / event log functions.\n\n\n\n\n Indication LEDs\n\n\n\n Function Keys 1-4\nThese keys will activate the\nfunction as displayed above\nthem on the OLED display\n Up/Down, Left/Right\nThese keys are used to navigate\nthe menus and information\ndisplayed.\n\n\n\n\n© 2023 Carrier 3\n\f Key Function\n EK Press this key to select the Status and Engineer's Key Data (EK) modes.\n Fuel Press this key to change the Fuel/Profile. If you change fuel when the burner\n is firing, the burner will go OFF and then restart, firing the new fuel selection.\n *\n On/Off Press this key to switch the burner ON or OFF, and to enable changes\n Mode between Normal and Local operation.\n\n Note: Terminal PE6 must be ON for this switch to start the burner.\n Mute Press this key to mute (open) the alarm relays, and then press and hold the\n Reset key down for approximately three seconds to reset the cleared faults.\n\n The Fuel key will have no function when used with the Fireye PPC6000.\n\n\n When using the 3G-OTH-02838 and NX6330 displays, the password entry expects a 6-figure number,\n entered in two phases/sets. Press F4 COM to enter Commissioning, Site, and Adjust Ratio\n passcodes. See examples below:\n\n When entering Commissioning passcode with 000 displayed scroll up entering first phase/set then\n Press [ENTER] scroll up entering second phase/set then Press [ENTER].\n\n When entering passcode for Site and ADJ Ratio with 000 displayed press the right arrow key,\n then\n scroll up entering Site or Adjust Ratio passcodes then Press [ENTER].\n\n Example:\n 000 Shown scroll up to XXX then Press [ENTER] scroll up to XXX [ENTER] equalling\n Commissioning.\n 000 Shown Press > then scroll up to XXX equalling Adjust Ratio number then Press [ENTER].\n 000 Shown Press > then scroll up to XXX equalling Site Passcode number then Press [ENTER].\n\n\n To obtain Commissioning, Adjust Ratio, and Site Passcodes consult with Fireye or OEM.\n\n\n\n\n© 2023 Carrier 4\n\f1.1 System Overview / Main Screen\nThe system overview is the default information displayed during normal operation of the burner.\n\n\n\n Current\n Current\n modulation\n Operating\n mode.\n mode.\n Currently\n Unit address.\n selected\n fuel profile.\n Burner\n Burner Information\n Status\n\n Soft Keys\n F1-4\n\n\n System Overview Screen\n\n\n\n\n Key Function\n F1 Selects the modulation modes (AUTO, MAN).\n F2 Selects the LFH.\n F3 Opens the Data screen, which shows further operational data of the controls.\n F4 Enters commissioning mode.\n\n\nNote: The soft keys have multiple functions. The default functions are shown on the line\nabove each key in the System Overview screen above. As you navigate through the\nvarious modes, the appropriate key functions will appear above each soft key F1 through F4.\n\n\n\n\n© 2023 Carrier 5\n\f2.Engineers Key\nThis is the Engineers Key screen, it is used to view the value or status of various control parameters.\nIt is accessed using the Engineers Key on the keypad.\n Engineers Key\nTo enter: Press EK ,\n\n\n\n\nAt Engineers Keys Screen, then Scroll up or Down through the screen information.\n\n\n\n\n Current\n Faults on\n System\n\n Engineers\n Keys Values\n and\n Descriptions\n\n\n\nSoft Keys\n F1-4\n\n\n\n SEE Section 6 of Fireye Bulleting NEX-6101 or PPC6001\n [Fault and Fault Finding] for Engineers Key Descriptions.\n\n\n\n Key Function\n F1 Exit Engineers Key screen and return to the system overview.\n F2 Displays the fault log for the display.\n\n\n\n\n© 2023 Carrier 6\n\f2.1 Fault Log\n\nTo Access from the…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Fireye 3G-OTH-02838 and NX6330 are 12-key keypad displays from the Touchscreens & Displays category. These models are CE and UL Listed. The product is available under SKU 3G-OTH-02838, and the series also includes NX6100 and PPC6000 models.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Fireye 3G-OTH-02838 and NX6330 keypad display used for?

The Fireye 3G-OTH-02838 and NX6330 OLED 12-key keypad displays provide an operator interface for commissioning and operating Fireye NX6100 or PPC6000 series controls. They feature four multifunction soft keys that group related options during commissioning, making setup quicker and reducing the risk of skipping related settings.

What are the specifications of the Fireye 3G-OTH-02838 and NX6330?

The Fireye 3G-OTH-02838 is a basic OLED display with a USB port, while the NX6330 adds an Ethernet port for MODbus TCP/IP or BACnet integration into building automation systems. Both models include a tactile membrane keypad with click feedback, a lithium-ion battery for backup, and support English, French, and Spanish languages. Approvals include CE and UL Listed.

Where to buy Fireye 3G-OTH-02838 or NX6330 in Singapore?

3G Electric supplies the Fireye 3G-OTH-02838 and NX6330 keypad displays to customers in Singapore. We source these genuine Fireye components and handle logistics, customs clearance, and delivery to your facility. Contact our team for pricing and lead time on orders.

How to install the Fireye 3G-OTH-02838 or NX6330 keypad display?

Installation involves mounting the display and connecting it to a compatible Fireye NX6100 or PPC6000 series control. The NX6330 requires an Ethernet connection for BAS integration. Refer to Fireye bulletin NXD-6301 for wiring details. The lithium-ion battery maintains backup during power loss, so ensure proper handling per manufacturer guidelines.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye touchscreens & displays. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Nexus NX6100 Integrated Parallel Positioning. Fireye proudly presents the NX6100, an advanced fully integrated parallel positioning system. Designed to deliver unparalleled performance in the smallest footprint in the industry—measuring just 5 x 8.25 x 3.75 inches—the NX6100 sets a new standard in efficiency and functionality. Also available in Nexus PPC6000
Fireye
Nexus NX6100 Integrated Parallel Positioning. Fireye proudly presents the NX6100, an advanced fully integrated parallel positioning system. Designed to deliver unparalleled performance in the smallest footprint in the industry—measuring just 5 x 8.25 x 3.75 inches—the NX6100 sets a new standard in efficiency and functionality. Also available in Nexus PPC6000
Nexus NXF4000 Parallel Positioning. The Fireye NXF4000 is an advanced burner management controller with an internal flame safeguard, designed to operate burners firing liquid or gaseous fuels. NXF4000 supports up to four servos and two VFD channels per profile, optional touchscreen interface, 15 configurable digital inputs, optional valve proving, thermal shock, hot standby, integrated peer-to-peer sequencing and more. Add-on options include oxygen trim, plant master for centralized control and communication gateway to support most BMS/PLC/SCADA needs
Fireye
Nexus NXF4000 Parallel Positioning. The Fireye NXF4000 is an advanced burner management controller with an internal flame safeguard, designed to operate burners firing liquid or gaseous fuels. NXF4000 supports up to four servos and two VFD channels per profile, optional touchscreen interface, 15 configurable digital inputs, optional valve proving, thermal shock, hot standby, integrated peer-to-peer sequencing and more. Add-on options include oxygen trim, plant master for centralized control and communication gateway to support most BMS/PLC/SCADA needs
PMSTR-6000 Plant Master for NX6100 and PPC6000. The Fireye PMSTR-6000 Plant Master offers sequencing and control for up to ten NX6100 or PPC6000 efficiency controls for steam and hot water plant applications. A 10.4” touchscreen interface is supplied for setup and monitoring
Fireye
PMSTR-6000 Plant Master for NX6100 and PPC6000. The Fireye PMSTR-6000 Plant Master offers sequencing and control for up to ten NX6100 or PPC6000 efficiency controls for steam and hot water plant applications. A 10.4” touchscreen interface is supplied for setup and monitoring
NXDBMB Modbus RTU Interface Card. The NXDBMB Modbus RTU interface card is an essential component designed specifically for the PPC6000 and NX6100 systems. This powerful interface card enables seamless networking of up to 15 Fireye Nexus systems, making it a crucial addition for those looking to enhance their industrial automation capabilities
Fireye
NXDBMB Modbus RTU Interface Card. The NXDBMB Modbus RTU interface card is an essential component designed specifically for the PPC6000 and NX6100 systems. This powerful interface card enables seamless networking of up to 15 Fireye Nexus systems, making it a crucial addition for those looking to enhance their industrial automation capabilities
Nexus NX6300 Parallel Positioning. The newest member of the versatile 6000 series family of combustion efficiency burner controls that can be configured to control a variety of burner applications
Fireye
Nexus NX6300 Parallel Positioning. The newest member of the versatile 6000 series family of combustion efficiency burner controls that can be configured to control a variety of burner applications
The Fireye NX6100 is an integrated parallel positioning control for burner management systems. It coordinates fuel and air damper actuators to optimize combustion efficiency and reduce emissions. Suitable for commercial and industrial boilers, furnaces, and process heaters
Fireye
The Fireye NX6100 is an integrated parallel positioning control for burner management systems. It coordinates fuel and air damper actuators to optimize combustion efficiency and reduce emissions. Suitable for commercial and industrial boilers, furnaces, and process heaters

More from Fireye

View all Fireye parts
NXTSD507HD and NXTSD512HD Enhanced Touchscreen Interfaces. The NXTSD507HD and NXTSD512HD enhanced touchscreen interfaces offer expanded capability beyone what the standard NXD410TS keypad can offer. These touchscreens can be used either with an existing NXD410TS or in place of one, allowing both monitoring and commissioning. Multiple controls can connect to one touchscreen, and auxiliary devices such as the BurnerLogix, YZ300 interlock annunciator and ABB VFDs can also be connected for more complete monitoring. Remote monitoring via VNC and a Modbus server are also standard features
Fireye
NXTSD507HD and NXTSD512HD Enhanced Touchscreen Interfaces. The NXTSD507HD and NXTSD512HD enhanced touchscreen interfaces offer expanded capability beyone what the standard NXD410TS keypad can offer. These touchscreens can be used either with an existing NXD410TS or in place of one, allowing both monitoring and commissioning. Multiple controls can connect to one touchscreen, and auxiliary devices such as the BurnerLogix, YZ300 interlock annunciator and ABB VFDs can also be connected for more complete monitoring. Remote monitoring via VNC and a Modbus server are also standard features
BLV512 and BLL510 Display Modules. The BurnerLogiX system offers an optional OLED or liquid crystal (LCD) display that may be either plugged in or mounted remotely to give full language descriptors of current status and diagnostic lockout information
Fireye
BLV512 and BLL510 Display Modules. The BurnerLogiX system offers an optional OLED or liquid crystal (LCD) display that may be either plugged in or mounted remotely to give full language descriptors of current status and diagnostic lockout information
NXTSD104 Touchscreen Display. The NXTSD104 touch-screen display system offers versatile connectivity solutions to enhance its integration with various devices and networks. Here’s an overview of the connectivity options available:
Fireye
NXTSD104 Touchscreen Display. The NXTSD104 touch-screen display system offers versatile connectivity solutions to enhance its integration with various devices and networks. Here’s an overview of the connectivity options available:
NXD410TS Touchscreen Interface. The NXD410TS provides the means to setup, monitor and display information from the NXF4000 and PPC4000 series of controls as well as any connected accessories. It provides a full touchscreen interface for monitoring, configuration and commissioning. The NXD410TS touchscreen is panel mounted and connects to the NXF4000 or PPC4000 control using a serial communication cable
Fireye
NXD410TS Touchscreen Interface. The NXD410TS provides the means to setup, monitor and display information from the NXF4000 and PPC4000 series of controls as well as any connected accessories. It provides a full touchscreen interface for monitoring, configuration and commissioning. The NXD410TS touchscreen is panel mounted and connects to the NXF4000 or PPC4000 control using a serial communication cable
ED510 Display Module. The ED510 Display Module is engineered to integrate seamlessly with the Flame-Monitor Burner Management Control System. It is compatible with EP and EPD style (remote mount only for EPD style) programmer modules, as well as the MicroM series of controls
Fireye
ED510 Display Module. The ED510 Display Module is engineered to integrate seamlessly with the Flame-Monitor Burner Management Control System. It is compatible with EP and EPD style (remote mount only for EPD style) programmer modules, as well as the MicroM series of controls