We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Fireye Series Bi-Flame Dual Burner Monitoring System. Obsolete - Process Burner Controls
FireyeProcess Burner Controls

Fireye Series Bi-Flame Dual Burner Monitoring System. Obsolete

The Fireye BF Series Bi-Flame Dual Burner Monitoring System is a process burner control designed for dual-burner monitoring. The system is available in model MB600S and carries cULus and FM Approvals, ensuring…

SKU 3G-OTH-02810

Also listed as: BFBIDUALMONITORINGSYSTEM · BF BI DUAL MONITORING SYSTEM

Brand
Fireye
Item
Series Bi-Flame Dual Burner Monitoring System. Obsolete
Category
Process Burner Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Fireye
Models
MB600S
Category
Process Burner Controls
Approvals
cULus, FM Approved

Datasheet Content

[{"filename":"MF-00-2-0700-0-006-B_BF_Series_Bi-Flame_Dual_Burner_Monitoring_Sys.pdf","text":"BF Series Bi-Flame Dual\nBurner Monitoring System\nBF22P1211-FR and\nBF22P1212-FR\nControls startup sequence and monitors\nflame for two individual burners\n\nThe Fireye Bi-Flame Monitoring System controls the startup\nsequence and monitors the flame of two individual gas, oil, or\ncombination gas/oil burners connected to a common valve train.\nIts dynamic onboard testing checks for faulty relays, proof of valve\nclosure, high and low fire switch interlocks, and shorted air switch.\n\nIts dip switches allow sequence and timing functions, as well as\nsystem configuration. It is also capable of modulation (high and\nlow fire purging) and monitoring up to four auxiliary inputs. It is UL\n\n\n\n\n SERIES\nrecognized in the US and Canada, and FM approved.\n\nFeatures .\n • LED indicator lights provide operating and alarm status\n • Combustion air flow check terminal\n BF\n • Main fuel valve proof of closure terminal\n • Low fire start terminal\n • High fire purge check terminal\n • Recycle mode\n • Pilot test mode\n • Interrupted or intermittent pilot\n • Spark, pilot flame & main flame separation\n • 4 auxiliary inputs\n • Real time flame signal test jacks\n • Optional alpha numerical display with history log\n\nAvailable flame sensor options:\n • Rectification ionization flame rod\n • Ultraviolet (UV)\n • UV self check\n\n\n\n\nFor more information, please contact your local Fireye Distributor.\nfireye.com\nMF-00-2-0700-0-005-B (2024/08)\nAll trademarks and service marks referred herein are property of their respective owners.\n©2024 Fireye. All Rights Reserved.\n\n Join us on"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Fireye BF Series Bi-Flame Dual Burner Monitoring System is a process burner control designed for dual-burner monitoring. The system is available in model MB600S and carries cULus and FM Approvals, ensuring compliance with recognized safety standards.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Fireye BF Series Bi-Flame Dual Burner Monitoring System used for?

The Fireye BF Series Bi-Flame Dual Burner Monitoring System controls the startup sequence and monitors the flame of two individual gas, oil, or combination gas/oil burners connected to a common valve train. It is used in industrial process burner applications requiring dual-burner supervision.

What are the specifications of the Fireye BF Series Bi-Flame system?

The Fireye BF Series includes models BF22P1211-FR and BF22P1212-FR. It features dynamic onboard testing for faulty relays, proof of valve closure, high/low fire switch interlocks, and shorted air switch. It supports up to four auxiliary inputs and is UL recognized and FM approved.

Where to buy the Fireye BF Series Bi-Flame system in Singapore?

3G Electric supplies the Fireye BF Series Bi-Flame Dual Burner Monitoring System to Singapore. We source and deliver this obsolete model or its replacement, the MB Series MB600S Burner Control, handling logistics and customs clearance for your facility.

How to replace the Fireye BF Series with the MB600S Burner Control?

To replace the obsolete Fireye BF Series Bi-Flame system, use the MB Series MB600S Burner Control. Consult the Fireye MB600S manual for wiring and configuration. 3G Electric can provide sourcing support for the MB600S, which is cULus and FM approved.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye process burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
SB Series Flame Safeguard. The Fireye SB Series flame safeguard control is a compact, microprocessor based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process equipment firing any type of fuel
Fireye
SB Series Flame Safeguard. The Fireye SB Series flame safeguard control is a compact, microprocessor based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process equipment firing any type of fuel
Flame-Monitor E110 Flame Safeguard. In conjunction with limit and operating controls, the Flame-Monitor E110 programs the burner/blower motor, ignition and fuel valves to provide for proper and safe burner operation. The control also provides current operating status and lockout information in the event of a safety shutdown
Fireye
Flame-Monitor E110 Flame Safeguard. In conjunction with limit and operating controls, the Flame-Monitor E110 programs the burner/blower motor, ignition and fuel valves to provide for proper and safe burner operation. The control also provides current operating status and lockout information in the event of a safety shutdown
M-Series II Flame Safeguard MC120. Modular M-Series II Flame Safeguard Controls are compact, modular burner management systems. They are designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use gas and/or light oil fuels
Fireye
M-Series II Flame Safeguard MC120. Modular M-Series II Flame Safeguard Controls are compact, modular burner management systems. They are designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use gas and/or light oil fuels
BurnerLogix Z Flame Safeguard. The BurnerLogix Z (ZB110) System expands on the standard BurnerLogix Y System by combining boiler control functions with the same burner management control found in the Y system
Fireye
BurnerLogix Z Flame Safeguard. The BurnerLogix Z (ZB110) System expands on the standard BurnerLogix Y System by combining boiler control functions with the same burner management control found in the Y system
Flame sensor for use in HVACR and burner systems. Detects flame presence and signals the control system to maintain fuel supply only when a stable flame is present, preventing unburned fuel accumulation
Fireye
Flame sensor for use in HVACR and burner systems. Detects flame presence and signals the control system to maintain fuel supply only when a stable flame is present, preventing unburned fuel accumulation
BurnerLogiX Y Flame Safeguard. The BurnerLogix flame safeguard controler boast a sophisticated array of features designed to enhance efficiency, safety, and ease of use in combustion systems. Employing built-in techniques and algorithms, the BurnerLogix is equipped to learn and adapt to the unique characteristics of the fuel being burned. This intelligent system dynamically sets internal thresholds, optimizing detection accuracy under a diverse range of operating conditions. When firing conditions deviate unfavorably, the adaptive IR system swiftly and safely initiates a shutdown of the burner, mitigating potential risks
Fireye
BurnerLogiX Y Flame Safeguard. The BurnerLogix flame safeguard controler boast a sophisticated array of features designed to enhance efficiency, safety, and ease of use in combustion systems. Employing built-in techniques and algorithms, the BurnerLogix is equipped to learn and adapt to the unique characteristics of the fuel being burned. This intelligent system dynamically sets internal thresholds, optimizing detection accuracy under a diverse range of operating conditions. When firing conditions deviate unfavorably, the adaptive IR system swiftly and safely initiates a shutdown of the burner, mitigating potential risks

More from Fireye

View all Fireye parts
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
Fireye
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
Fireye
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
MBCE Flame Sensor Modules. The modules use Fireye flame rods or UV scanners to sense flame presence independently or as components in a burner management system. These modules have many operational characteristics are provided including:
Fireye
MBCE Flame Sensor Modules. The modules use Fireye flame rods or UV scanners to sense flame presence independently or as components in a burner management system. These modules have many operational characteristics are provided including:
MB Series MB600S Burner Control. MB SERIES control has been engineered to meet the operational, safety and reliability requirements demanded by the industrial process heat market. It is a fully integrated control, complete with all functions built into one module, offering the opportunity to greatly reduce cost and space requirements normally required by other non-integrated systems
Fireye
MB Series MB600S Burner Control. MB SERIES control has been engineered to meet the operational, safety and reliability requirements demanded by the industrial process heat market. It is a fully integrated control, complete with all functions built into one module, offering the opportunity to greatly reduce cost and space requirements normally required by other non-integrated systems