We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Fireye 45UV5 Series UV Flame Scanners. These 45UV5 models are used only with the Flame-Monitor
FireyeUV Flame Scanners

Fireye 45UV5 Series UV Flame Scanners. These 45UV5 models are used only with the Flame-Monitor

The Fireye 3G-OTH-02849 Series are UV Flame Scanners, designed for industrial flame detection. They are approved with CE, FM Approved, and UL Listed certifications.

SKU 3G-OTH-02849

Brand
Fireye
Item
45UV5 Series UV Flame Scanners. These 45UV5 models are used only with the Flame-Monitor
Category
UV Flame Scanners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Fireye
Models
45UV5
Category
UV Flame Scanners
Approvals
CE, FM Approved, UL Listed

Datasheet Content

[{"filename":"CU-45-Multi-Purpose_Power_Supply_19MPS-2000_English_11-04-2013.pdf","text":"\n\n CU-45\n APRIL 11, 2013\n\n\n\n\n 19MPS-2000\n MULTI-PURPOSE\n POWER SUPPLY\n\n\n\nDESCRIPTION\n The 19MPS-2000 is a rack mounted power supply which operates on either 120 or 220 VAC input\n power (switch selectable - Factory set for 220 VAC operation), and provides supply voltage for two\n (2) 25SU3-2000 or -2100 amplifiers and up to four (4) low voltage (e.g. 45RM4, 45FS1, 45UVFS1)\n or line voltage (e.g. 45RM1, 45RM2, 3G-OTH-02849) flame scanners in any combination. The 19MPS-2000\n will fit into the Fireye 19\" full rack (P/N 60-2471-3), 19\" half rack (60-2471-1), or surface mounted\n wiring rack (60-2530). When used with the 19\" full or half rack (60-2471-3,-1), a 60-2481 or 60-\n 2482 connector is required and must be ordered separately. A green LED indicates when power is\n applied to the 19MPS-2000 power supply.\n\n\nORDERING INFORMATION\n P/N Description\n 19MPS-2000 Multi-purpose power supply (120 or 220 VAC)\n (Factory set for 220 VAC operation).\n 60-2481 Screw terminal type connector for 19MPS-2000\n 60-2482 Spade terminal type connector for 19MPS-2000\n\n\nSPECIFICATIONS\n Electrical Electrical supply to the 19MPS-2000 is 120 or 220 VAC, 50/60 Hz.\n Switch selectable. (Factory set for 220 VAC operation).\n Maximum current output = 650 ma.\n\n ENVIRONMENTAL\n Storage Temp: Minimum - 4 F (-20 C)\n Maximum 176 F (80 C)\n Operating Temp: Minimum - 4 F (-20 C)\n Maximum 140 F (60 C)\n Humidity: Maximum 85% Relative Humidity (Non-condensing).\n\n\n\n\n 1\n\f \n\n\n\n SELECT INPUT VOLTAGE\n The 19MPS-2000 power supply will operate on either 120 VAC or 220 VAC. Input voltage is\n selected by a blue slide switch (SW1) mounted on the printed circuit board near the face plate.\n\n CAUTION: THE 19MPS-2000 POWER SUPPLY IS SHIPPED FROM THE FACTORY\n SET FOR 220 VAC OPERATION. To select 120 VAC operation, use a small screwdriver to\n move the blue slideswitch to the 120 VAC position (away from the faceplate).\n\n\n\nINSTALLATION\n For 60-2530: Slide the 19MPS-2000 multi-purpose power supply (if required) into the card guides\n on the far left slot of the 60-2530 wiring rack until the card mates with the connector mounted on the\n back of the wiring rack. Tighten the two screws on the top and bottom of the 60-2350 wiring rack to\n secure the power supply.\n For 60-2471-1: The 19MPS-2000 will fit into the existing guide racks on the 19\" half rack (60-2471-\n 1). The 60-2481 or 60-2482 connector can be screwed into positions 4, 14, or 24. Tighten the two\n screws on the top and bottom of the 19\" half rack to secure the power supply.\n Note: The 60-2478 connector supplied with the half rack for use with the 25SU3-2000 amplifier is\n screwed into position 34.\n For 60-2471-3: The 19MPS-2000 will fit into the existing guide racks on the 19\" full rack (60-2471-\n 3). The 60-2481 or 60-2482 connector can be screwed into positions 6, 16, 36, 46, or 56. Tighten the\n two screws on the top and bottom of the 19\" full rack to secure the power supply.\n Note: The 60-2478 connector supplied with the full rack for use with the 25SU3-2000 amplifier is\n screwed into position 76.\n\n CAUTION: DO NOT REMOVE THE 19MPS-2000 POWER SUPPLY MODULE WITH\n POWER APPLIED. THIS MAY RESULT IN POSSIBLE EQUIPMENT DAMAGE.\n\n\n\nTERMINAL CONNECTIONS on 19MPS-2000\n 4\n Terminal # Function\n 6\n 4 +24 VDC Output (to 25SU3-2000, -2100 amplifiers). 8\n 16, 22, 24, 261 120VAC Output Power for Line Voltage Scanners 10\n (e.g. 45RM1, 45RM2, and 3G-OTH-02849). 12\n 14\n 14, 182 Common (return) for line voltage scanners, 16\n common (return) for 24VDC (to 25SU3-2000, -2100\n 18\n amplifiers). 20\n 28 Neutral (L2) 22\n 24\n 30 120/220 VAC Input (L1). Fused for 400mA3.\n 26\n 32 Earth Ground . 28\n\n 6, 8, 10, 12, Not Used . 30\n 32\n\n\n 60-2482\n CONNECTOR\n\n\n 1. Connect only one line voltage scanner to each terminal. (Power for the low voltage scanners is supplied via the 25SU3 am-\n\n plifier).\n 2.\n Terminals 14 and 18 are internally connected.\n 3. Replacement fuse Fireye P/N 23-194 (Wickman TR 5 #19372-040-K).\n\n\n2\n\f \n\n\n\n\nWIRING CONNECTIONS\n For 60-2530 (Surface Mount Rack): Follow the wiring connections detailed in Bulletin CU-44.\n For 60-2471-1, -3 (19\" Full or Half Rack): Use Figure 1 below.\n\nFIGURE 1. 19MPS-2000 power supply to two (2) 25SU3-2000, -2100 amplifiers, each amplifier with one low voltage\n scanner (45RM4, 45FS1, or 45UVFS1) and one line voltage scanners (45RM1, 45RM2, or 3G-OTH-02849).\n\n 45RM1, 45RM2, OR 3G-OTH-02849 45RM1, 45RM2, OR 3G-OTH-02849\n\n SCANNER SCANNER\n A BLACK BLACK\n A\n POWER L L POWER\n WHITE WHITE\n COMMON C C COMMON\n RED RED\n SHUTTER 1 1 SHUTTER\n GREEN GREEN\n SIGNAL 14 14 SIGNAL\n\n 45RM4, 45FS1, OR 45RM4, 45FS1, OR\n 45UVFS1 45UVFS1\n SCANNER SCANNER\n B BLACK B\n POWER 1\n BLACK 1 POWER\n WHITE\n WHITE COMMON\n COMMON\n RED RED\n SHUTTER 2 2 SHUTTER\n GREEN\n SIGNAL 3 GREEN\n 3 SIGNAL\n\n\n *\n D2 Z2 4 D2 Z2\n * D4 Z4 14 /18 D4 Z4\n D6 Z6 16 D6 Z6\n D8 Z8 22 D8 Z8\n SHIELD\n D28 28- L2 D28 SHIELD\n\n D30 30- L1…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Fireye 3G-OTH-02849 Series are UV Flame Scanners, designed for industrial flame detection. They are approved with CE, FM Approved, and UL Listed certifications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Fireye 3G-OTH-02849 UV flame scanner used for?

The Fireye 3G-OTH-02849 UV flame scanner is used with Flame-Monitor, BurnerLogix, D-Series, FlameWorx, MicroM and some P-Series Fireye control models to provide flame safeguard and monitoring for single burner boilers, process ovens and heaters.

What are the specifications of the Fireye 3G-OTH-02849?

The Fireye 3G-OTH-02849 is a UV flame scanner in the 3G-OTH-02849 Series. It carries CE, FM, and UL approvals. It is a line voltage scanner compatible with specific Fireye control models for supervised manual, semi-automatic and fully automatic burner systems.

Where to buy Fireye 3G-OTH-02849 in Singapore?

You can source the Fireye 3G-OTH-02849 UV flame scanner through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this Fireye model.

How to install the Fireye 3G-OTH-02849 flame scanner?

Install the Fireye 3G-OTH-02849 by mounting it in a compatible Fireye rack such as the 19MPS-2000 power supply rack. Ensure the scanner is properly connected to the control module. Follow the manufacturer's wiring diagram and safety guidelines for burner management systems.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye uv flame scanners. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
UV5 Series UV Flame Scanners. The UV5-1 and UV5-2 are high-performance ultraviolet (UV) flame scanners designed for accurate and reliable flame monitoring in industrial and commercial burner systems. These UV scanners feature 6.5 ft. UL-rated cables, ensuring safe, efficient, and straightforward installation while meeting stringent safety and quality standards
Fireye
UV5 Series UV Flame Scanners. The UV5-1 and UV5-2 are high-performance ultraviolet (UV) flame scanners designed for accurate and reliable flame monitoring in industrial and commercial burner systems. These UV scanners feature 6.5 ft. UL-rated cables, ensuring safe, efficient, and straightforward installation while meeting stringent safety and quality standards
Phoenix Series 2 85UV & 85IR Flame Scanners. The Fireye Phoenix Series 2 85UVF/IRF flame scanners are advanced, microprocessor-based devices featuring solid-state ultraviolet (UV) or infrared (IR) sensors for precise and reliable flame detection. Engineered for high performance, these scanners include an internal flame relay with auto-adjusting ON/OFF thresholds, eliminating the need for external flame amplifiers or switches
Fireye
Phoenix Series 2 85UV & 85IR Flame Scanners. The Fireye Phoenix Series 2 85UVF/IRF flame scanners are advanced, microprocessor-based devices featuring solid-state ultraviolet (UV) or infrared (IR) sensors for precise and reliable flame detection. Engineered for high performance, these scanners include an internal flame relay with auto-adjusting ON/OFF thresholds, eliminating the need for external flame amplifiers or switches
InSight Series 4 95S4UV & 95IRS4 Flame Scanner. The Fireye InSight® Series 4 flame scanners, including models 95UVS4 and 95IRS4, are advanced, fully microprocessor-based devices featuring solid-state ultraviolet (UV) or infrared (IR) sensors. These integrated flame scanners eliminate the need for separate amplifiers or flame switch modules, offering streamlined installation and enhanced functionality
Fireye
InSight Series 4 95S4UV & 95IRS4 Flame Scanner. The Fireye InSight® Series 4 flame scanners, including models 95UVS4 and 95IRS4, are advanced, fully microprocessor-based devices featuring solid-state ultraviolet (UV) or infrared (IR) sensors. These integrated flame scanners eliminate the need for separate amplifiers or flame switch modules, offering streamlined installation and enhanced functionality
UV7SC Self-Check Flame Scanner. The UV7SC is a high-performance, self-check ultraviolet flame scanner, designed for continuous monitoring of gas or oil flames. It integrates with Fireye’s MBSERIES Multi-Burner and SBSERIES Single Burner controls, as well as the MBPF-100S and MB-600PF flame sensing modules
Fireye
UV7SC Self-Check Flame Scanner. The UV7SC is a high-performance, self-check ultraviolet flame scanner, designed for continuous monitoring of gas or oil flames. It integrates with Fireye’s MBSERIES Multi-Burner and SBSERIES Single Burner controls, as well as the MBPF-100S and MB-600PF flame sensing modules

More from Fireye

View all Fireye parts
Fireye
Fireye
UV1AL Series UV Flame Scanners
Fireye
Fireye
45UV3 Series UV Flame Scanners. The 45UV3 Scanner is a durable and reliable ultraviolet flame scanner designed for industrial and commercial flame detection applications. Featuring a rugged cast housing, this scanner is built to withstand harsh operating environments while ensuring long-lasting performance and reliability
Fireye
Fireye
UV8A Series UV Flame Scanners. The UV8A Scanner is a 90° right-angle ultraviolet flame scanner designed for reliable flame detection. Compatible with M-Series, M-Series II, MicroM, FlameWorx, MB-2, D series controls, as well as Fireye® FLAME-MONITOR, BurnerLogix, and the Nexus System, the UV8A offers versatile integration for various burner management systems
Simplicity 65UV5 UV Flame Scanner. The 65UV5 scanner is available with a one-second or four-second flame failure response time (FFRT) depending on the model selected. The “E” versions are one-second FFRT, the non ”E” versions are four seconds FFRT. The Fireye 65UV5-1004QD and 1004EQD flame scanners provide an analog 4 to 20 mA output referenced to flame signal strength
Fireye
Simplicity 65UV5 UV Flame Scanner. The 65UV5 scanner is available with a one-second or four-second flame failure response time (FFRT) depending on the model selected. The “E” versions are one-second FFRT, the non ”E” versions are four seconds FFRT. The Fireye 65UV5-1004QD and 1004EQD flame scanners provide an analog 4 to 20 mA output referenced to flame signal strength
UV90 Series UV Flame Scanners. The UV90 Series Scanners are state-of-the-art ultraviolet flame scanners specifically designed for both front and lateral (90°) mounting, offering enhanced flexibility and performance in a variety of flame detection applications. These versatile UV scanners are engineered to provide a clearer and more accurate view of the flame in applications where line-of-sight positioning can impact performance
Fireye
UV90 Series UV Flame Scanners. The UV90 Series Scanners are state-of-the-art ultraviolet flame scanners specifically designed for both front and lateral (90°) mounting, offering enhanced flexibility and performance in a variety of flame detection applications. These versatile UV scanners are engineered to provide a clearer and more accurate view of the flame in applications where line-of-sight positioning can impact performance
UV90L Series UV Flame Scanners. The UV scanner is ideally suited for gaseous fuels (natural gas & propane). However, it can be used in detecting flames from standard fuel gases, some waste gases and light oil fuels such as No. 2 oil. Flames from heavier oils can be detected with UV scanners but the unburned fuel shroud and/or atomization shroud can block the passage of the UV from the flame zone to the UV tube, causing nuisance burner/boiler trips. Infrared detection is recommended for fuel oil heavier than No. 2, and some installations where waste gases are burned together with natural gas as the main flame
Fireye
UV90L Series UV Flame Scanners. The UV scanner is ideally suited for gaseous fuels (natural gas & propane). However, it can be used in detecting flames from standard fuel gases, some waste gases and light oil fuels such as No. 2 oil. Flames from heavier oils can be detected with UV scanners but the unburned fuel shroud and/or atomization shroud can block the passage of the UV from the flame zone to the UV tube, causing nuisance burner/boiler trips. Infrared detection is recommended for fuel oil heavier than No. 2, and some installations where waste gases are burned together with natural gas as the main flame
55UV5 Series UV Flame Scanners. 55UV5 self-checking scanners are used to detect ultraviolet emissions from fossil fuel flames such as natural gas, coke oven gas, propane, methane, butane, kerosene, light petroleum distillates and diesel fuels and are suitable for use in Class I, Div. 2, Groups A, B, C, D and Class II, Div. 2 Groups F and G hazardous locations. These 55UV5 models are used only with the Flame-Monitor™, D-Series, FlameWorx and MicroM control models to provide flame safeguard and monitoring systems for supervised manual, semi-automatic and fully automatic single burner boilers, process ovens and heaters
Fireye
55UV5 Series UV Flame Scanners. 55UV5 self-checking scanners are used to detect ultraviolet emissions from fossil fuel flames such as natural gas, coke oven gas, propane, methane, butane, kerosene, light petroleum distillates and diesel fuels and are suitable for use in Class I, Div. 2, Groups A, B, C, D and Class II, Div. 2 Groups F and G hazardous locations. These 55UV5 models are used only with the Flame-Monitor™, D-Series, FlameWorx and MicroM control models to provide flame safeguard and monitoring systems for supervised manual, semi-automatic and fully automatic single burner boilers, process ovens and heaters
UV7A4, UV7A4-1-CEX & UV7R4 Flame Scanners. The UV7A4, UV7A4-1-CEX and UV7R4 are high-sensitivity ultraviolet (UV) flame scanners designed for monitoring gas or oil flames that cycle frequently. These non-self-check scanners integrate seamlessly with Fireye’s MBSERIES Multi-Burner control, SBSERIES Single Burner control, and the MBPF-100S and MB-600PF flame sensing modules, providing reliable flame detection for various industrial applications
Fireye
UV7A4, UV7A4-1-CEX & UV7R4 Flame Scanners. The UV7A4, UV7A4-1-CEX and UV7R4 are high-sensitivity ultraviolet (UV) flame scanners designed for monitoring gas or oil flames that cycle frequently. These non-self-check scanners integrate seamlessly with Fireye’s MBSERIES Multi-Burner control, SBSERIES Single Burner control, and the MBPF-100S and MB-600PF flame sensing modules, providing reliable flame detection for various industrial applications