The EXTECH Handheld Temperature Calibrator (model PRC20) is a thermocouple calibrator that measures voltage from -10mV DC to 60mV DC. It covers a temperature range of -58°F to 2,498°F (-50°C to 1,750°C) and is…

SKU 3G-OTH-178624

Also listed as: PRC 20 · PRC-20

Brand
EXTECH
Item
PRC20 Handheld Thermocouple Calibrator, -10mV DC to 60mV DC
Category
Handheld Thermocouple Calibrators
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

EXTECH
Manufacturer Part Number
PRC20
Type
-10mV DC to 60mV DC
For RTD Type
Thermocouple
Parameters Measured
Voltage

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EXTECH Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EXTECH Handheld Temperature Calibrator (model PRC20) is a thermocouple calibrator that measures voltage from -10mV DC to 60mV DC. It covers a temperature range of -58°F to 2,498°F (-50°C to 1,750°C) and is designed for use with thermocouple RTD types.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the EXTECH PRC20 handheld temperature calibrator used for?

The EXTECH PRC20 is used to calibrate thermocouple-based temperature sensors and instruments in industrial process control, HVAC, and laboratory settings. It measures voltage from -10mV DC to 60mV DC and covers a temperature range of -58°F to 2,498°F (-50°C to 1,750°C).

What are the specifications of the EXTECH PRC20 calibrator?

The EXTECH PRC20 is a handheld thermocouple calibrator that measures voltage from -10mV DC to 60mV DC. It supports a temperature range of -58°F to 2,498°F (-50°C to 1,750°C) and is designed for thermocouple RTD types. The manufacturer part number is PRC20.

Where to buy the EXTECH PRC20 calibrator worldwide?

3G Electric supplies the EXTECH PRC20 handheld temperature calibrator worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to use the EXTECH PRC20 calibrator for thermocouple calibration?

To use the EXTECH PRC20, connect the thermocouple to the input terminals, select the voltage measurement mode, and compare the reading against a reference standard. Ensure proper polarity and ambient temperature compensation. For best results, follow generic thermocouple calibration best practices and consult the EXTECH manual.

Used in

Common applications for EXTECH
HVAC system diagnostics — EXTECH AN340 vane anemometer for air velocity and humidity measurement
Industrial machinery maintenance — EXTECH 461995 laser tachometer for RPM and surface speed checks
Food and beverage quality testing — EXTECH RF12 analog refractometer for Brix concentration measurement
Refrigerant leak detection — EXTECH RD350 heated diode leak detector for R-513A systems
Environmental monitoring — EXTECH RH490 data logging hygro-thermometer for temperature and humidity logging
Lighting inspection — EXTECH LT300-NIST light meter for illuminance measurement in workspaces

EXTECH Products

3G Electric supplies EXTECH handheld thermocouple calibrators. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
EXTECH Digital Thermometer: -58°F to 572°F /-50°C to 300°C, ±1.8°F/1°C @ -22 to 482°F/-30 to 250°C (MPN 39272)
EXTECH
EXTECH Digital Thermometer: -58°F to 572°F /-50°C to 300°C, ±1.8°F/1°C @ -22 to 482°F/-30 to 250°C (MPN 39272)
EXTECH Thermocouple Thermometer: -200°F to 1,999°F, 2 Channels, RS-232/SD Card (MPN EA15-NIST)
EXTECH
EXTECH Thermocouple Thermometer: -200°F to 1,999°F, 2 Channels, RS-232/SD Card (MPN EA15-NIST)
EXTECH Thermocouple Thermometer: -58°F to 1,999°F, For Type K Thermocouple Type, -58°F to 1,999°F (MPN EA11A-NIST)
EXTECH
EXTECH Thermocouple Thermometer: -58°F to 1,999°F, For Type K Thermocouple Type, -58°F to 1,999°F (MPN EA11A-NIST)
The EXTECH EA15 is a two-channel thermocouple meter with a measurement range of -200°F to 1,999°F. It supports Type J, K, E, T, and N thermocouples with an accuracy of ±0.05 % + 1.5 °F/0.75 °C. The meter includes an average temperature function and features RS-232 and SD card connectivity for data output. Suitable for temperature measurement in industrial, HVAC, and laboratory settings
EXTECH
The EXTECH EA15 is a two-channel thermocouple meter with a measurement range of -200°F to 1,999°F. It supports Type J, K, E, T, and N thermocouples with an accuracy of ±0.05 % + 1.5 °F/0.75 °C. The meter includes an average temperature function and features RS-232 and SD card connectivity for data output. Suitable for temperature measurement in industrial, HVAC, and laboratory settings
The EXTECH EA11A is a thermocouple meter designed for use with Type K thermocouples, measuring temperatures from -58°F to 1,999°F. It offers an accuracy of ±0.3% + 2°F/1°C and supports average temperature testing. This instrument is suited for monitoring furnaces, ovens, and exhaust systems in industrial and HVAC applications
EXTECH
The EXTECH EA11A is a thermocouple meter designed for use with Type K thermocouples, measuring temperatures from -58°F to 1,999°F. It offers an accuracy of ±0.3% + 2°F/1°C and supports average temperature testing. This instrument is suited for monitoring furnaces, ovens, and exhaust systems in industrial and HVAC applications
EXTECH TM100-NIST is a thermocouple meter for Type J and Type K thermocouples, measuring temperatures from -346°F to 2,501°F. It features Min/Max temperature testing functions with an accuracy of ±0.15 % + 1 °C. This model does not include data output. Typical applications include industrial maintenance, HVAC diagnostics, and laboratory testing
EXTECH
EXTECH TM100-NIST is a thermocouple meter for Type J and Type K thermocouples, measuring temperatures from -346°F to 2,501°F. It features Min/Max temperature testing functions with an accuracy of ±0.15 % + 1 °C. This model does not include data output. Typical applications include industrial maintenance, HVAC diagnostics, and laboratory testing

More from EXTECH

View all EXTECH parts
EXTECH Handheld Temperature Calibrator: -58°F to 2,498°F /-50°C to 1,750°C, -5mV to 55mV (MPN PRC30)
EXTECH
EXTECH Handheld Temperature Calibrator: -58°F to 2,498°F /-50°C to 1,750°C, -5mV to 55mV (MPN PRC30)
EXTECH Handheld Temperature Calibrator: -58°F to 2,498°F /-50°C to 1,750°C, -5mV to 55mV (MPN PRC30-NIST)
EXTECH
EXTECH Handheld Temperature Calibrator: -58°F to 2,498°F /-50°C to 1,750°C, -5mV to 55mV (MPN PRC30-NIST)