We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Elektrogas NC automatic reset multiple valve - Safety Solenoid Valves
ElektrogasSafety Solenoid Valves

Elektrogas NC automatic reset multiple valve

The Elektrogas VMM is an NC automatic reset multiple safety solenoid valve for air and non-aggressive gases (Family 1-2-3, EN 437), with special versions for biogas/COG and hydrogen. It is offered with operating…

SKU 3G-OTH-02643

Brand
Elektrogas
Item
NC automatic reset multiple valve
Category
Safety Solenoid Valves
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Elektrogas
Gas type
Air and non-aggressive gases (Family 1-2-3, EN 437) / Special version for Biogas/COG / Special version for Hydrogen (H2)
Approvals
CE approved / FM approved / EAC approved / Australian Gas Mark
Operating pressure
0 … 200 mbar / 0 … 360 mbar / 0 … 500 mbar
Material/Connections
AlSi Rp3/4 … Rp 2 / AlSi DN40 … DN80

Datasheet Content

[{"filename":"VMM_en.pdf","text":"VMM\n\n Multiple safety solenoid valve\n for gas regulating trains\n DN20 … DN80\n\n\n\n\ndelta-elektrogas.com EE163 -0124\n\f ELEKTROGAS – Technical Sheet EE163 - 0124\n\n\n\nVMM\nMultiple safety solenoid valve\nfor gas regulating trains\n\nContents\n Description ………………………………………….. 2\n Features …………………………………………….. 2\n Functioning and application ………………………. 3\n Technical specifications …………………………… 4\n Gas flow chart (pressure drop) …………………… 6\n Ordering information ………………………………. 8\n Special versions and options …….….….………… 9\n Design, installation and servicing ........................ 10\n Standards and approvals …………………………. 11\n\n\nDescription The VMM type valve is a combination of two solenoid valves in an only compact and versatile\n valve housing.\n This type of device is suitable for air or gas blocking and releasing controls (with one or two stages\n operation), required in gas power burners, atmospheric gas boiler, industrial kilns and others gas\n consuming appliances.\n\n\n\nFeatures VMM valves are made of aluminum alloy die-cast, with a range for inlet/outlet connections from\n DN20 (3/4”) up to DN80 (3”).\n Sealings are made of NBR-based rubber certified for use with gas (EN 549).\n Pipe connections meet group 2 and backpressure sealing is compliant with class A, according to\n EN161 requirements.\n A third valve with capacity of DN15 or DN25 can be fitted to by-pass the second one and have a\n low fire stage or a second outlet for pilot burner (pilot execution).\n The normally open vent valve VMRNA can be integrated in VMM from 1”¼ to 3”; dimensions and\n piping are the same of third pilot valve. See VMRNA datasheet for other details.\n Suitable for use with air and non-aggressive gases included in the 1, 2 and 3 families (EN 437).\n Special versions suitable for aggressive gases, free of brass and with FPM seals.\n The whole range can be provided in Ex-proof execution, for use in Zones 2 and 22, according to\n 2014/34/EU Directive (ATEX).\n The valve is open only when energized: if, for any reason, power supply goes down, the valve\n closes immediately (intrinsic safe).\n Suitable for heavy-duty cycle operation and qualified for continuous service (100% ED).\n Equipped with flow rate adjustment.\n An incorporated fine mesh filter protects the valve seat and disc as well as downstream\n components and prevents dirty contamination.\n A proof of closure switch or a visual indicator can be installed (see PCS-VI datasheet for details);\n in this case the valve has to be equipped with 1/8” connection on the bottom (optional).\n Models from 2”½-3” have this features as standard.\n Provided with bilateral pressure ports on two sides in all pressure chambers, to connect\n manometers, pressure switches, leakage tester or other gas equipment.\n The coils are provided with terminal box or with ISO 4400 plug.\n All components are designed to withstand any mechanical, chemical and thermal condition\n occurring during typical service. Effective impregnation and surface treatments have been used\n to improve mechanical sturdiness, sealing and resistance to corrosion of the components.\n Valves are 100% tested by computerized testing machineries and are fully warranted.\n\n\n 2-11\n\f ELEKTROGAS – Technical Sheet EE163 - 0124\n\n\n\n\nFunctioning and\napplication The VMM type valve is a safety shutting device using auxiliary power supply.\n The first valve (A) is a fast-opening safety solenoid valve. When it is de-energized, the spring\n pushes on the seal disc, keeping the gas passage closed. In the inlet chamber there is the gas\n line pressure which forces on the disc, increasing the closing function and improving the seal.\n When the coil is powered, the valve opens rapidly against the strength of the spring and gas\n pressure.\n If the power supply is shut off, the valve rapidly closes, interrupting the gas flow.\n Equally, the second valve (B) may be a fast opening or a slow opening solenoid valve to adjust\n the gas flow, with a first adjustable fast stroke and a second adjustable slow stroke.\n It is possible to connect a third by-pass valve (C), which works as low fire stage or to obtain a\n second fast (slow) stroke or both.\n\n 1 1 = Ball valve\n 2 = Filter\n 3 = Pressure regulator\n 11 4 = Tightness control\n 5 = Minimum gas pressure switch\n 6 = Tightness control pressure switch\n 7 = Multiple solenoid valve\n A 8 = Valve position visual indicator\n 9 = Closed position indicator switch\n 10 = Burner pressure gauge\n 11 = Push button valve\n\n\n A = First valve\n B = Second valve\n C = By-pass valve (pilot)\n 8 X = Inlet chamber\n Y = Middle chamber\n 4 Z = Outlet chamber\n\n\n\n (The above scheme refers to size 1 \"¼-2\" with third valve as by-pass)\n\n Fig.1\n\n\n This kind of valve is normally installed as safety and regulating device in gas trains, for industrial\n applications and gas firing systems.\n Figure 2 shows an example of installation.\n\n\n\n\n Fig.2\n\n\n\n\n 3-11\n\f ELEKTROGAS – Technical Sheet EE163 - 0124\n\n\n\n\nTechnical\nspecifications Tab. 1\n Connections Internal threaded EN 10226-1 from Rp3/4 to Rp2 or\n ANSI-ASME 1.2 from 3/4”NPT to 2”NPT\n Flanged PN16 – ISO 7005 from DN40 to DN80 or\n ANSI-ASA-ASME 1 . class 1 from 2” to 3”\n\n By-pass size DN15 or DN25\n\n Voltage rating 230 VAC 50/60 Hz\n 120 VAC 50/60 Hz\n 110 VAC 50/60 Hz\n 24 VAC/DC\n\n Voltage tolerance -15% / +10%\n\n Power consumption 70W for 3/4” – 1”\n 90W (working) for 1”¼ -3”\n by-pass 1/2\" 25W\n by-pass 1\" 35W\n\n Ambient temperature -15°C / +60°C (+5°F to +140°F)\n Media temperature\n\n Max. operating pressure 200 mbar (3 psig)\n 500 mbar (5 psig)\n\n Max test pressure 1 bar (15 psig)\n\n Flow capacity see charts\n\n Closing time < 1 second\n\n Opening time Adjustable\n\n Pressure ports G1/4 (additional G1/8 onto flanged models)\n\n Gas strainer 600 µm (0.02 in), metal mesh\n\n Enclosure IP54 (NEMA 3)\n optional IP65 with cable (NEMA 4)\n\n Cable gland M20x1,5 for terminal box\n PG 9 for ISO plug\n\n Wires cross-section 2,5 mm2 max. (AWG 12) for terminal board\n 1,5 mm2 max. (AWG 14) for ISO plug\n\n Electrical safety Class I (EN 60335-1)\n\n Coil winding insulation Class H (200°C, 392°F)\n\n Coil thermal resistance Class F (155°C, 311°F)\n\n\n\n\n 4-11\n\f ELEKTROGAS – Technical Sheet EE163 - 0124\n\n\n\n\n Fig.3\n Tab. 2\n Overall dimensions (mm/in) Weight\n Model\n A B C D E F G H I (Kg/lbs)\n VMM….F 154/6,06 185/7,28 78/3,07 130/5,12 165/6,50 112/4,41 - - 5,4/11,9\n Rp3/4\n VMM….S 3/4”NPT 154/6,06 185/7,28 78/3,07 186/7,32 221/8,70 112/4,41 - - 5,8/12,8\n\n VMM….S1 Rp1 154/6,06 185/7,28 78/3,07 186/7,32 221/8,70 194/7,64 - - 7,1/15,7\n 1”NPT\n VMM….S2 154/6,06 185/7,28 78/3,07 186/7,32 221/8,70 194/7,64 - - 7,5/16,5\n\n VMM….F 211/8,31 280/11,02 127/5,00…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Elektrogas Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Elektrogas VMM is an NC automatic reset multiple safety solenoid valve for air and non-aggressive gases (Family 1-2-3, EN 437), with special versions for biogas/COG and hydrogen. It is offered with operating pressure ranges of 0 to 200 mbar, 0 to 360 mbar, or 0 to 500 mbar, and features AlSi construction with Rp3/4 to Rp2 threaded or DN40 to DN80 flanged connections. The valve carries CE, FM, EAC, and Australian Gas Mark approvals.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the Elektrogas VMM multiple valve used for?

The Elektrogas VMM multiple safety solenoid valve is used for gas or air blocking and releasing controls in gas power burners, atmospheric gas boilers, industrial kilns, and other gas equipment requiring regulating trains. It houses two solenoid valves in one body for two-stage operation.

What are the specifications of the Elektrogas VMM valve?

The VMM valve handles air and non-aggressive gases (families 1-2-3, EN 437) with operating pressure up to 500 mbar. Connections range from Rp3/4 to Rp2 (AlSi) or DN40 to DN80 (AlSi). It is CE, FM, EAC, and Australian Gas Mark approved. Elektrogas offers special versions for biogas and hydrogen.

Where to buy the Elektrogas VMM valve in Singapore?

3G Electric supplies the Elektrogas VMM multiple safety solenoid valve to Singapore. We source and deliver this valve, handling logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on your specific configuration.

How to install the Elektrogas VMM multiple valve?

Install the VMM valve in a gas regulating train with proper pipe connections per EN161 group 2. Ensure the flow direction matches the arrow on the body. The valve is normally closed and opens only when energized. Use the incorporated fine mesh filter to protect downstream components. Consult the Elektrogas datasheet for detailed installation guidelines.

Used in

Common applications for Elektrogas
Industrial steam and hot-water boiler gas trains — VMR slow-opening solenoid valves on modulating burners
Commercial kitchen and bakery gas-fired ovens — VML magnetic valves for appliance-level safety shut-off
Process-industry gas supply skids — VMH high-pressure variants rated to 6 bar for elevated-pressure networks
Burner OEM gas-train assemblies — multibloc combined-function units reducing commissioning and leak paths
Retrofit drop-in replacements for existing Elektrogas VMR valves on installed burner racks

Elektrogas Products

3G Electric supplies Elektrogas safety solenoid valves. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
NC automatic reset slow opening fast closing. The VMH-type valve is a shut-off valve for gaseous media operated by a hydraulic actuator. It is suitable as main safety device for gas blocking and gas releasing controls, as required when operating gas burners, atmospheric gas boilers, industrial kilns, and generally all gas-consuming appliances. When the actuator gets energized, it slowly opens the valve over a few seconds. Once fully open, the hydraulic pump turns off to minimize power consumption. As soon as the power supply stops, the valve closes immediately (<1 sec). It is qualified for continuous service (100% ED)
Elektrogas
NC automatic reset slow opening fast closing. The VMH-type valve is a shut-off valve for gaseous media operated by a hydraulic actuator. It is suitable as main safety device for gas blocking and gas releasing controls, as required when operating gas burners, atmospheric gas boilers, industrial kilns, and generally all gas-consuming appliances. When the actuator gets energized, it slowly opens the valve over a few seconds. Once fully open, the hydraulic pump turns off to minimize power consumption. As soon as the power supply stops, the valve closes immediately (<1 sec). It is qualified for continuous service (100% ED)
NC solenoid valve for air control fast/slow opening fast/slow closing. The VRA – VLA – VTA types are normally closed solenoid valves for regulation of cold combustion air. When the coil is unenergized, the spring pushes on the disk to keep the adjusted minimum air passage. The valve opens when the coil is powered, moving the disc to the maximum open position. The valve moves to the minimum position when the power is off. This type of device is suitable for high/low stage control of combustion air in industrial gas burners. (qualified for continuous service- 100% ED)
Elektrogas
NC solenoid valve for air control fast/slow opening fast/slow closing. The VRA – VLA – VTA types are normally closed solenoid valves for regulation of cold combustion air. When the coil is unenergized, the spring pushes on the disk to keep the adjusted minimum air passage. The valve opens when the coil is powered, moving the disc to the maximum open position. The valve moves to the minimum position when the power is off. This type of device is suitable for high/low stage control of combustion air in industrial gas burners. (qualified for continuous service- 100% ED)
Solenoid valve VML1 tapped D1/2" 500 Mbar
Elektrogas
Solenoid valve VML1 tapped D1/2" 500 Mbar
Elektrogas
Elektrogas
Solenoid valve VML3 tapped D1" 500 Mbar
Elektrogas
Elektrogas
Solenoid valve VML2 threaded D3/4" 500 Mbar
Solenoid valve VMR 3 threaded D1" 500 Mbar
Elektrogas
Solenoid valve VMR 3 threaded D1" 500 Mbar

More from Elektrogas

View all Elektrogas parts
NC/NO manual reset safety valve for gas fast closing. The EVRM-NA –NC type valve is a manual reset safety valve for gas. A manual operation is necessary to open the valve while shut off is completely automatic and operated by solenoid. This type of device, connected with one or more leakage detectors or alarm signals for the presence of carbon monoxide or any other type of alarm system that can operate a power supply, is suitable for performing locking operations on the gas line
Elektrogas
NC/NO manual reset safety valve for gas fast closing. The EVRM-NA –NC type valve is a manual reset safety valve for gas. A manual operation is necessary to open the valve while shut off is completely automatic and operated by solenoid. This type of device, connected with one or more leakage detectors or alarm signals for the presence of carbon monoxide or any other type of alarm system that can operate a power supply, is suitable for performing locking operations on the gas line
NO automatic reset vent valve fast opening fast closing. VMRNA type is an automatic vent valve for gas appliances. It is suitable for discharging gas excess or gas leakage into relief lines. VMRNA valve is a reverse acting solenoid valve: when deenergized, the valve is open (N.O. normally open). VMRNA valve can be integrated in Elektrogas VMM multiple valve to obtain a very compact system
Elektrogas
NO automatic reset vent valve fast opening fast closing. VMRNA type is an automatic vent valve for gas appliances. It is suitable for discharging gas excess or gas leakage into relief lines. VMRNA valve is a reverse acting solenoid valve: when deenergized, the valve is open (N.O. normally open). VMRNA valve can be integrated in Elektrogas VMM multiple valve to obtain a very compact system
NC automatic reset slow opening fast closing. The VML-type valve is a normally closed safety valve with slow opening and adjustable rapid stroke for initial gas flow. When not in the working position, the spring pushes on the disc, keeping the gas passage closed. When the coil is powered, the valve opens slowly, with adjustable speed. If an initial rapid stroke is set, valve opens rapidly in the first section. The valve rapidly shuts when the power is off. This type of device is suitable for gas and air blocking and adjusting controls in atmospheric burners or fan-assisted burners, in industrial kilns, and in all gas equipment that uses gas solenoid valves (qualified for continuous service – 100% ED)
Elektrogas
NC automatic reset slow opening fast closing. The VML-type valve is a normally closed safety valve with slow opening and adjustable rapid stroke for initial gas flow. When not in the working position, the spring pushes on the disc, keeping the gas passage closed. When the coil is powered, the valve opens slowly, with adjustable speed. If an initial rapid stroke is set, valve opens rapidly in the first section. The valve rapidly shuts when the power is off. This type of device is suitable for gas and air blocking and adjusting controls in atmospheric burners or fan-assisted burners, in industrial kilns, and in all gas equipment that uses gas solenoid valves (qualified for continuous service – 100% ED)
NC automatic reset fast opening fast closing. The VMR-type valve is a normally closed solenoid valve that is fast-opening. When the coil is unenergized, the spring pushes on the disc to keep the gas passage closed. When the coil is powered, the valve opens. The valve rapidly shuts when the power is off. This type of device is suitable for gas and air blocking and adjusting controls in atmospheric burners or fan-assisted burners, industrial kilns, and all gas equipment that uses gas solenoid valves (qualified for continuous service – 100% ED)
Elektrogas
NC automatic reset fast opening fast closing. The VMR-type valve is a normally closed solenoid valve that is fast-opening. When the coil is unenergized, the spring pushes on the disc to keep the gas passage closed. When the coil is powered, the valve opens. The valve rapidly shuts when the power is off. This type of device is suitable for gas and air blocking and adjusting controls in atmospheric burners or fan-assisted burners, industrial kilns, and all gas equipment that uses gas solenoid valves (qualified for continuous service – 100% ED)