We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

EATON NEMA Size 2 Reversing Starter - Reversing Starters with Electronic Overloads
EATONReversing Starters with Electronic Overloads

EATON NEMA Size 2 Reversing Starter

The EATON NEMA Magnetic Motor Starter: Reversing (MPN AN59GN0A5E020) is a three-phase reversing starter with an electronic overload, NEMA Size 2, rated 45 A, and a 110/120V AC coil. It includes a 1NO auxiliary…

SKU 3G-OTH-43265

Brand
EATON
Item
NEMA Size 2 Reversing Starter
Category
Reversing Starters with Electronic Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

EATON
Manufacturer Part Number
AN59GN0A5E020
Type
NEMA Size 2, 45 A
Phase
Three
Poles
3
AC Coil
120V
Operator
None
Coil Voltage
110/120V AC
Operator Controls
None
Signaling Features
Pilot Light
Auxiliary Contact Form
1NO
Thermal Units Required
None (Not Applicable to Electronic Overloads)
Auxiliary Contacts Included
1NO

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EATON NEMA Magnetic Motor Starter: Reversing (MPN AN59GN0A5E020) is a three-phase reversing starter with an electronic overload, NEMA Size 2, rated 45 A, and a 110/120V AC coil. It includes a 1NO auxiliary contact and a pilot light signaling feature, with no operator or operator controls.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the EATON NEMA Magnetic Motor Starter AN59GN0A5E020 used for?

This EATON reversing starter controls three-phase motors in applications requiring forward/reverse operation, such as conveyors, hoists, and pumps. It includes an electronic overload for motor protection and a pilot light for status indication.

What are the specifications of the EATON AN59GN0A5E020 reversing starter?

The EATON AN59GN0A5E020 is a NEMA Size 2 reversing starter rated 45 A with a 110/120V AC coil. It has three poles, one normally open auxiliary contact, and an electronic overload. No thermal units are required. It includes a pilot light signaling feature.

Where to buy the EATON AN59GN0A5E020 reversing starter worldwide?

3G Electric supplies the EATON AN59GN0A5E020 reversing starter worldwide. As a global industrial distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to select the correct overload for the EATON AN59GN0A5E020 starter?

The EATON AN59GN0A5E020 uses an electronic overload, so no separate thermal units are needed. Set the overload according to the motor's full-load current rating, following the manufacturer's instructions. Always verify compatibility with your motor's voltage and phase.

Used in

Common applications for EATON
Industrial control panels — Eaton M22 flush push buttons for momentary machine start/stop commands
Motor control centers — Eaton NEMA reversing starters with electronic overloads for conveyor belt direction control
HVAC systems — Eaton definite purpose starters with thermal overloads for compressor and fan motor protection
Process automation — Eaton SL7 tower lights with IP66 bases for visual status indication in wet environments
Machine tool signaling — Eaton 10250T LED pilot lights with push-to-test for operator panel status lamps
Access control — Eaton M22 keyed selector switches for equipment mode selection in secured areas

EATON Products

3G Electric supplies EATON reversing starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 2, 45 A, 120V AC Coil (MPN AN59GN0A5E045)
EATON
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 2, 45 A, 120V AC Coil (MPN AN59GN0A5E045)
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 2, 45 A, 120V AC Coil (MPN AN59GN0A5E005)
EATON
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 2, 45 A, 120V AC Coil (MPN AN59GN0A5E005)
Three-phase NEMA Size 1 reversing starter rated 27 A with a 110/120V AC coil. Features an electronic overload (no thermal units required), a pilot light, and one normally open auxiliary contact. Suitable for forward and reverse control of three-phase motors in industrial applications such as conveyors, hoists, and pumps
EATON
Three-phase NEMA Size 1 reversing starter rated 27 A with a 110/120V AC coil. Features an electronic overload (no thermal units required), a pilot light, and one normally open auxiliary contact. Suitable for forward and reverse control of three-phase motors in industrial applications such as conveyors, hoists, and pumps
Three-phase reversing starter for motor control, NEMA Size 3 rated 90 A with 110/120V AC coil. Includes electronic overload protection, 1NO auxiliary contact, and pilot light for status indication. Suitable for starting, stopping, and reversing motors in industrial applications such as conveyors and pumps
EATON
Three-phase reversing starter for motor control, NEMA Size 3 rated 90 A with 110/120V AC coil. Includes electronic overload protection, 1NO auxiliary contact, and pilot light for status indication. Suitable for starting, stopping, and reversing motors in industrial applications such as conveyors and pumps
Three-phase reversing starter, NEMA Size 0, rated 9 A, with 110/120V AC coil. Includes electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light for signaling. Suitable for reversing motor direction in applications such as conveyors, hoists, and pumps
EATON
Three-phase reversing starter, NEMA Size 0, rated 9 A, with 110/120V AC coil. Includes electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light for signaling. Suitable for reversing motor direction in applications such as conveyors, hoists, and pumps
Three-phase NEMA Size 1 reversing starter rated 27 A with 110/120V AC coil. Electronic overload protection eliminates need for thermal units. Includes pilot light for status indication and one normally open auxiliary contact. Suitable for reversing direction of three-phase motors in industrial applications such as conveyors, pumps, and hoists
EATON
Three-phase NEMA Size 1 reversing starter rated 27 A with 110/120V AC coil. Electronic overload protection eliminates need for thermal units. Includes pilot light for status indication and one normally open auxiliary contact. Suitable for reversing direction of three-phase motors in industrial applications such as conveyors, pumps, and hoists

More from EATON

View all EATON parts
Three-phase NEMA Size 2 reversing starter rated 45 A with electronic overload protection. Features a 440/480V AC coil, 1 normally open auxiliary contact, and a pilot light for signaling. Suitable for starting, stopping, and reversing three-phase motors in industrial applications such as conveyors, pumps, and heavy-duty machinery
EATON
Three-phase NEMA Size 2 reversing starter rated 45 A with electronic overload protection. Features a 440/480V AC coil, 1 normally open auxiliary contact, and a pilot light for signaling. Suitable for starting, stopping, and reversing three-phase motors in industrial applications such as conveyors, pumps, and heavy-duty machinery
Three-phase NEMA Size 1 reversing starter rated 27 A with 24V AC coil. Electronic overload protection eliminates thermal units. Includes one normally open auxiliary contact and pilot light. Used for starting, stopping, and reversing three-phase motors in industrial applications such as conveyors, hoists, and pumps
EATON
Three-phase NEMA Size 1 reversing starter rated 27 A with 24V AC coil. Electronic overload protection eliminates thermal units. Includes one normally open auxiliary contact and pilot light. Used for starting, stopping, and reversing three-phase motors in industrial applications such as conveyors, hoists, and pumps
Three-phase reversing starter with integrated electronic overload protection, rated 18 A at NEMA Size 0. Features a 220/240V AC coil, one normally open auxiliary contact, and a pilot light for status indication. Suitable for starting, stopping, and reversing three-phase motors in applications such as conveyors, pumps, and compressors
EATON
Three-phase reversing starter with integrated electronic overload protection, rated 18 A at NEMA Size 0. Features a 220/240V AC coil, one normally open auxiliary contact, and a pilot light for status indication. Suitable for starting, stopping, and reversing three-phase motors in applications such as conveyors, pumps, and compressors
Three-phase reversing starter with electronic overload protection, NEMA Size 0, rated 9 A. Features a 110/120V AC coil, one normally open auxiliary contact, and a pilot light for status indication. Suitable for reversing three-phase motors in applications such as conveyors, hoists, and pumps. No thermal units required
EATON
Three-phase reversing starter with electronic overload protection, NEMA Size 0, rated 9 A. Features a 110/120V AC coil, one normally open auxiliary contact, and a pilot light for status indication. Suitable for reversing three-phase motors in applications such as conveyors, hoists, and pumps. No thermal units required
Three-phase NEMA Size 0 reversing starter rated 9 A with 3 poles and 220/240V AC coil. Includes electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light for status indication. Suitable for reversing three-phase motors in applications such as conveyors, hoists, and pumps
EATON
Three-phase NEMA Size 0 reversing starter rated 9 A with 3 poles and 220/240V AC coil. Includes electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light for status indication. Suitable for reversing three-phase motors in applications such as conveyors, hoists, and pumps
Three-phase NEMA Size 0 reversing starter rated 18 A with 208V AC coil. Includes electronic overload (no thermal units required), one normally open auxiliary contact, and a pilot light. Used for reversing motor direction in applications such as conveyors, hoists, and pumps
EATON
Three-phase NEMA Size 0 reversing starter rated 18 A with 208V AC coil. Includes electronic overload (no thermal units required), one normally open auxiliary contact, and a pilot light. Used for reversing motor direction in applications such as conveyors, hoists, and pumps
Three-phase reversing starter with electronic overload, NEMA Size 0, rated 9 A. Includes 208V AC coil, 1 normally open auxiliary contact, and pilot light for signaling. No operator or operator controls provided. Used for starting, stopping, and reversing three-phase motors in applications such as conveyors, pumps, and fans
EATON
Three-phase reversing starter with electronic overload, NEMA Size 0, rated 9 A. Includes 208V AC coil, 1 normally open auxiliary contact, and pilot light for signaling. No operator or operator controls provided. Used for starting, stopping, and reversing three-phase motors in applications such as conveyors, pumps, and fans
Three-phase NEMA Size 3 reversing starter rated 90 A with a 24V AC coil. Includes an electronic overload (no thermal units required), one normally open auxiliary contact, and a pilot light for status indication. Used for forward/reverse control of three-phase motors in applications such as conveyors, hoists, and pumps
EATON
Three-phase NEMA Size 3 reversing starter rated 90 A with a 24V AC coil. Includes an electronic overload (no thermal units required), one normally open auxiliary contact, and a pilot light for status indication. Used for forward/reverse control of three-phase motors in applications such as conveyors, hoists, and pumps