We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

EATON AN19GN0C5E020 Non-Reversing Starter with Electronic Overload - Non-Reversing Starters with Electronic Overloads
EATONNon-Reversing Starters with Electronic Overloads

EATON AN19GN0C5E020 Non-Reversing Starter with Electronic Overload

The EATON NEMA Magnetic Motor Starter is a non-reversing starter with electronic overloads, designed for three-phase applications. This NEMA Size 2 unit features a 45 A rating and a 440/480V AC coil voltage, with a…

SKU 3G-OTH-42976

Brand
EATON
Item
AN19GN0C5E020 Non-Reversing Starter with Electronic Overload
Category
Non-Reversing Starters with Electronic Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

EATON
Manufacturer Part Number
AN19GN0C5E020
Type
NEMA Size 2, 45 A
Phase
Three
Poles
3
AC Coil
480V
Operator
None
Coil Voltage
440/480V AC
Operator Controls
None
Signaling Features
Pilot Light
Auxiliary Contact Form
1NO
Thermal Units Required
None (Not Applicable to Electronic Overloads)
Auxiliary Contacts Included
1NO

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EATON NEMA Magnetic Motor Starter is a non-reversing starter with electronic overloads, designed for three-phase applications. This NEMA Size 2 unit features a 45 A rating and a 440/480V AC coil voltage, with a 1NO auxiliary contact and a pilot light for signaling. It requires no thermal units, as the electronic overload eliminates the need for them.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the EATON NEMA Magnetic Motor Starter used for?

The EATON NEMA Magnetic Motor Starter is used to start and stop three-phase motors in industrial applications such as pumps, fans, and conveyors. Its electronic overload protects the motor from damage without requiring thermal units, making it suitable for continuous-duty operations.

What are the specifications of the EATON AN19GN0C5E020 motor starter?

The EATON AN19GN0C5E020 is a NEMA Size 2, non-reversing starter rated 45 A with a 440/480V AC coil voltage. It includes one normally open auxiliary contact and a pilot light for signaling. The electronic overload eliminates the need for thermal units, simplifying setup.

Where to buy the EATON AN19GN0C5E020 motor starter worldwide?

You can source the EATON AN19GN0C5E020 motor starter through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations, ensuring the product reaches your facility reliably.

How to install the EATON NEMA Size 2 motor starter?

Mount the starter on a flat surface, connect three-phase power to the line terminals, and wire the motor to the load terminals. Set the electronic overload dial to the motor's full-load current. Ensure the 440/480V AC coil voltage matches your control circuit before energizing.

Used in

Common applications for EATON
Industrial control panels — Eaton M22 flush push buttons for momentary machine start/stop commands
Motor control centers — Eaton NEMA reversing starters with electronic overloads for conveyor belt direction control
HVAC systems — Eaton definite purpose starters with thermal overloads for compressor and fan motor protection
Process automation — Eaton SL7 tower lights with IP66 bases for visual status indication in wet environments
Machine tool signaling — Eaton 10250T LED pilot lights with push-to-test for operator panel status lamps
Access control — Eaton M22 keyed selector switches for equipment mode selection in secured areas

EATON Products

3G Electric supplies EATON non-reversing starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 480V AC Coil (MPN AN19GN0C5E045)
EATON
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 480V AC Coil (MPN AN19GN0C5E045)
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 480V AC Coil (MPN AN19GN0C5E005)
EATON
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 480V AC Coil (MPN AN19GN0C5E005)
Three-pole NEMA Size 2 non-reversing motor starter rated 45 A with 220/240V AC coil. Includes electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light. Suitable for starting and stopping three-phase motors in industrial applications such as pumps, fans, and conveyors
EATON
Three-pole NEMA Size 2 non-reversing motor starter rated 45 A with 220/240V AC coil. Includes electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light. Suitable for starting and stopping three-phase motors in industrial applications such as pumps, fans, and conveyors
EATON NEMA Size 3 non-reversing starter with electronic overload, rated 90 A, three-phase, three poles. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light signaling feature. Suitable for starting and stopping three-phase motors in applications such as pumps, fans, and conveyors
EATON
EATON NEMA Size 3 non-reversing starter with electronic overload, rated 90 A, three-phase, three poles. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light signaling feature. Suitable for starting and stopping three-phase motors in applications such as pumps, fans, and conveyors
Three-pole, non-reversing magnetic motor starter with electronic overload protection. NEMA Size 2, rated 45 A, 220/240V AC coil. Includes pilot light and one normally open auxiliary contact. For starting and stopping three-phase motors in industrial applications such as pumps, fans, and conveyors
EATON
Three-pole, non-reversing magnetic motor starter with electronic overload protection. NEMA Size 2, rated 45 A, 220/240V AC coil. Includes pilot light and one normally open auxiliary contact. For starting and stopping three-phase motors in industrial applications such as pumps, fans, and conveyors
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 208V AC Coil (MPN AN19GN0E5E045)
EATON
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 208V AC Coil (MPN AN19GN0E5E045)

More from EATON

View all EATON parts
Three-pole NEMA Size 00 non-reversing magnetic motor starter rated 9 A with 440/480V AC coil. Electronic overload protection eliminates need for thermal units. Includes one normally open auxiliary contact and pilot light. Used for starting and stopping three-phase motors in industrial applications such as conveyors, pumps, and fans
EATON
Three-pole NEMA Size 00 non-reversing magnetic motor starter rated 9 A with 440/480V AC coil. Electronic overload protection eliminates need for thermal units. Includes one normally open auxiliary contact and pilot light. Used for starting and stopping three-phase motors in industrial applications such as conveyors, pumps, and fans
Three-pole non-reversing motor starter with electronic overload protection, rated 270 A at NEMA Size 5. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and protecting three-phase motors in industrial applications
EATON
Three-pole non-reversing motor starter with electronic overload protection, rated 270 A at NEMA Size 5. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and protecting three-phase motors in industrial applications
Three-phase non-reversing magnetic motor starter with electronic overload protection. NEMA Size 0, 18 A rating, 3 poles, 440/480V AC coil. Includes one normally open auxiliary contact and a pilot light. No thermal units required. Suitable for starting and stopping three-phase AC motors in applications such as conveyors, pumps, and compressors
EATON
Three-phase non-reversing magnetic motor starter with electronic overload protection. NEMA Size 0, 18 A rating, 3 poles, 440/480V AC coil. Includes one normally open auxiliary contact and a pilot light. No thermal units required. Suitable for starting and stopping three-phase AC motors in applications such as conveyors, pumps, and compressors
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 45 A at NEMA Size 2. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase AC motors in applications such as pumps, fans, and conveyors
EATON
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 45 A at NEMA Size 2. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase AC motors in applications such as pumps, fans, and conveyors
Three-pole, non-reversing motor starter with electronic overload protection, rated 27 A at NEMA Size 1. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. No thermal units required. Suitable for starting and stopping three-phase motors in industrial applications
EATON
Three-pole, non-reversing motor starter with electronic overload protection, rated 27 A at NEMA Size 1. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. No thermal units required. Suitable for starting and stopping three-phase motors in industrial applications
This EATON non-reversing starter with electronic overload is a NEMA Size 00 unit rated 9 A for three-phase motors. It features a 208V AC coil, three poles, a pilot light, and one normally open auxiliary contact. The electronic overload eliminates the need for separate thermal units. Typical applications include controlling constant-speed machinery such as pumps, fans, and conveyors
EATON
This EATON non-reversing starter with electronic overload is a NEMA Size 00 unit rated 9 A for three-phase motors. It features a 208V AC coil, three poles, a pilot light, and one normally open auxiliary contact. The electronic overload eliminates the need for separate thermal units. Typical applications include controlling constant-speed machinery such as pumps, fans, and conveyors
Three-pole NEMA Size 2 non-reversing motor starter rated 45 A with electronic overload protection. Coil voltage 110/120V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase motors in industrial applications such as pumps, fans, and conveyors
EATON
Three-pole NEMA Size 2 non-reversing motor starter rated 45 A with electronic overload protection. Coil voltage 110/120V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase motors in industrial applications such as pumps, fans, and conveyors
Three-pole NEMA Size 1 non-reversing motor starter rated 27 A with 440/480V AC coil. Includes one normally open auxiliary contact and a pilot light for signaling. Electronic overload protection eliminates need for thermal units. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and fans
EATON
Three-pole NEMA Size 1 non-reversing motor starter rated 27 A with 440/480V AC coil. Includes one normally open auxiliary contact and a pilot light for signaling. Electronic overload protection eliminates need for thermal units. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and fans