We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

EATON Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A - Non-Reversing Starters with Electronic Overloads
EATONNon-Reversing Starters with Electronic Overloads

EATON Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A

The EATON NEMA Magnetic Motor Starter is a non-reversing starter with electronic overloads, featuring three poles, NEMA Size 00, and a 9 A rating. It operates with a 24V AC coil voltage and includes a pilot light and…

SKU 3G-OTH-41060

Brand
EATON
Item
Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A
Category
Non-Reversing Starters with Electronic Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

EATON
Manufacturer Part Number
AN19AN0T5E020
Type
NEMA Size 00, 9 A
Phase
Three
Poles
3
AC Coil
24V
Operator
None
Coil Voltage
24V AC
Operator Controls
None
Signaling Features
Pilot Light
Auxiliary Contact Form
1NO
Thermal Units Required
None (Not Applicable to Electronic Overloads)
Auxiliary Contacts Included
1NO

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EATON NEMA Magnetic Motor Starter is a non-reversing starter with electronic overloads, featuring three poles, NEMA Size 00, and a 9 A rating. It operates with a 24V AC coil voltage and includes a pilot light and one normally open auxiliary contact. This three-phase starter requires no thermal units, as it is designed for electronic overload protection.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the EATON NEMA Magnetic Motor Starter AN19AN0T5E020 used for?

This EATON non-reversing magnetic motor starter controls three-phase motors up to 9 A, providing electronic overload protection. It is commonly used in industrial machinery, conveyors, pumps, and HVAC equipment where reliable starting and overload protection are required.

What are the specifications of the EATON AN19AN0T5E020 starter?

The EATON AN19AN0T5E020 is a NEMA Size 00, 3-pole, non-reversing starter rated 9 A at 24V AC coil voltage. It includes one normally open auxiliary contact and a pilot light. Electronic overload protection eliminates the need for thermal units.

Where to buy the EATON AN19AN0T5E020 motor starter worldwide?

3G Electric supplies the EATON AN19AN0T5E020 motor starter to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time.

How to select the correct EATON NEMA magnetic motor starter for a motor?

Match the starter's NEMA size and ampere rating to the motor's full-load current and voltage. For the EATON AN19AN0T5E020, ensure the motor is three-phase, 9 A or less, and the control circuit uses 24V AC. Electronic overloads simplify setup by eliminating thermal unit selection.

Used in

Common applications for EATON
Industrial control panels — Eaton M22 flush push buttons for momentary machine start/stop commands
Motor control centers — Eaton NEMA reversing starters with electronic overloads for conveyor belt direction control
HVAC systems — Eaton definite purpose starters with thermal overloads for compressor and fan motor protection
Process automation — Eaton SL7 tower lights with IP66 bases for visual status indication in wet environments
Machine tool signaling — Eaton 10250T LED pilot lights with push-to-test for operator panel status lamps
Access control — Eaton M22 keyed selector switches for equipment mode selection in secured areas

EATON Products

3G Electric supplies EATON non-reversing starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Three-pole non-reversing motor starter with electronic overload protection, NEMA Size 00, rated 9 A. Includes a 24V AC coil, one normally open auxiliary contact, and a pilot light for signaling. No thermal units required. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and fans
EATON
Three-pole non-reversing motor starter with electronic overload protection, NEMA Size 00, rated 9 A. Includes a 24V AC coil, one normally open auxiliary contact, and a pilot light for signaling. No thermal units required. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and fans
Three-pole NEMA Size 00 non-reversing starter rated for 9 A with a 24V AC coil. Includes an electronic overload that eliminates the need for thermal units, one normally open auxiliary contact, and a pilot light for signaling. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and compressors
EATON
Three-pole NEMA Size 00 non-reversing starter rated for 9 A with a 24V AC coil. Includes an electronic overload that eliminates the need for thermal units, one normally open auxiliary contact, and a pilot light for signaling. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and compressors
Three-pole non-reversing motor starter with electronic overload protection, rated 9 A at NEMA Size 00. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for signaling. Suitable for starting and stopping three-phase motors in constant-direction applications such as pumps, fans, and conveyors
EATON
Three-pole non-reversing motor starter with electronic overload protection, rated 9 A at NEMA Size 00. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for signaling. Suitable for starting and stopping three-phase motors in constant-direction applications such as pumps, fans, and conveyors
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 0, 18 A, 24V AC Coil (MPN AN19BN0T5E005)
EATON
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 0, 18 A, 24V AC Coil (MPN AN19BN0T5E005)
Three-pole non-reversing motor starter with electronic overload protection, NEMA Size 00, rated 9 A. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for signaling. No thermal units required. Suitable for starting and stopping three-phase motors in applications such as pumps, fans, conveyors, and compressors
EATON
Three-pole non-reversing motor starter with electronic overload protection, NEMA Size 00, rated 9 A. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for signaling. No thermal units required. Suitable for starting and stopping three-phase motors in applications such as pumps, fans, conveyors, and compressors
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 0, 18 A, 24V AC Coil (MPN AN19BN0T5E020)
EATON
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 0, 18 A, 24V AC Coil (MPN AN19BN0T5E020)

More from EATON

View all EATON parts
This EATON non-reversing starter with electronic overload is a NEMA Size 1, three-phase, 3-pole unit rated 27 A. It operates on a 120V AC coil and includes a pilot light for visual status indication. The electronic overload provides motor protection without the need for thermal units. One normally open auxiliary contact is included. Typical applications include starting and stopping three-phase motors in industrial equipment such as conveyors, pumps, and compressors
EATON
This EATON non-reversing starter with electronic overload is a NEMA Size 1, three-phase, 3-pole unit rated 27 A. It operates on a 120V AC coil and includes a pilot light for visual status indication. The electronic overload provides motor protection without the need for thermal units. One normally open auxiliary contact is included. Typical applications include starting and stopping three-phase motors in industrial equipment such as conveyors, pumps, and compressors
Three-phase non-reversing motor starter with electronic overload protection, rated 90 A, NEMA Size 3, 3 poles, and 220/240V AC coil. Includes one normally open auxiliary contact and a pilot light for signaling. Suitable for starting and stopping AC motors in industrial applications such as conveyors, pumps, fans, and compressors
EATON
Three-phase non-reversing motor starter with electronic overload protection, rated 90 A, NEMA Size 3, 3 poles, and 220/240V AC coil. Includes one normally open auxiliary contact and a pilot light for signaling. Suitable for starting and stopping AC motors in industrial applications such as conveyors, pumps, fans, and compressors
Non-reversing starter with electronic overload protection, rated 1.2 A, 3 poles, maximum 600V AC. Features a selector switch for control and a 45mm B Frame width. No thermal units required. Suitable for starting and protecting single-speed motors in applications such as conveyors, pumps, and fans
EATON
Non-reversing starter with electronic overload protection, rated 1.2 A, 3 poles, maximum 600V AC. Features a selector switch for control and a 45mm B Frame width. No thermal units required. Suitable for starting and protecting single-speed motors in applications such as conveyors, pumps, and fans
Three-pole NEMA Size 00 non-reversing magnetic motor starter rated 9 A with 440/480V AC coil. Electronic overload protection eliminates need for thermal units. Includes one normally open auxiliary contact and pilot light. Used for starting and stopping three-phase motors in industrial applications such as conveyors, pumps, and fans
EATON
Three-pole NEMA Size 00 non-reversing magnetic motor starter rated 9 A with 440/480V AC coil. Electronic overload protection eliminates need for thermal units. Includes one normally open auxiliary contact and pilot light. Used for starting and stopping three-phase motors in industrial applications such as conveyors, pumps, and fans
Three-pole non-reversing motor starter with electronic overload protection, rated 270 A at NEMA Size 5. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and protecting three-phase motors in industrial applications
EATON
Three-pole non-reversing motor starter with electronic overload protection, rated 270 A at NEMA Size 5. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and protecting three-phase motors in industrial applications
Three-phase non-reversing magnetic motor starter with electronic overload protection. NEMA Size 0, 18 A rating, 3 poles, 440/480V AC coil. Includes one normally open auxiliary contact and a pilot light. No thermal units required. Suitable for starting and stopping three-phase AC motors in applications such as conveyors, pumps, and compressors
EATON
Three-phase non-reversing magnetic motor starter with electronic overload protection. NEMA Size 0, 18 A rating, 3 poles, 440/480V AC coil. Includes one normally open auxiliary contact and a pilot light. No thermal units required. Suitable for starting and stopping three-phase AC motors in applications such as conveyors, pumps, and compressors
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 45 A at NEMA Size 2. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase AC motors in applications such as pumps, fans, and conveyors
EATON
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 45 A at NEMA Size 2. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase AC motors in applications such as pumps, fans, and conveyors
Three-pole, non-reversing motor starter with electronic overload protection, rated 27 A at NEMA Size 1. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. No thermal units required. Suitable for starting and stopping three-phase motors in industrial applications
EATON
Three-pole, non-reversing motor starter with electronic overload protection, rated 27 A at NEMA Size 1. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. No thermal units required. Suitable for starting and stopping three-phase motors in industrial applications