EATON Circuit Breaker: 175 A Amps, 35 kA at 480V AC, Fixed, ABC, Std Terminals Load Only
The EATON Power Defense Molded Case Circuit Breaker (SKU 61HU28, MPN PDG23G0175TFFL) is a 175 A rated device with a 225A/Frame 2 frame size. It features a maximum AIR rating of 35 kA at 480V AC, fixed instantaneous…
SKU 3G-OTH-24692
Need installation or engineering help?
Ask a question
Product Description
The EATON Power Defense Molded Case Circuit Breaker (SKU 61HU28, MPN PDG23G0175TFFL) is a 175 A rated device with a 225A/Frame 2 frame size. It features a maximum AIR rating of 35 kA at 480V AC, fixed instantaneous trip, ABC phase connection, and standard terminals load only.
Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.
Frequently Asked Questions
What is the EATON PDG23G0175TFFL circuit breaker used for?
The EATON Power Defense molded case circuit breaker (PDG23G0175TFFL) protects electrical circuits from overloads and short circuits in commercial and industrial power distribution systems. Its 175 A rating and 35 kA interrupting capacity at 480V AC suit motor control centers, panelboards, and switchboards requiring reliable overcurrent protection.
What are the specifications of the EATON PDG23G0175TFFL circuit breaker?
This EATON Power Defense circuit breaker is rated 175 A with a 225A/Frame 2 frame size. It has a maximum AIR rating of 35 kA at 480V AC, fixed instantaneous trip, ABC phase connection, and standard terminals load only. The manufacturer part number is PDG23G0175TFFL.
Where to buy the EATON PDG23G0175TFFL circuit breaker worldwide?
3G Electric supplies the EATON PDG23G0175TFFL circuit breaker worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time on this Power Defense molded case circuit breaker.
How to select the correct EATON Power Defense circuit breaker for an application?
Select the EATON Power Defense circuit breaker by matching its continuous current rating (e.g., 175 A), interrupting capacity (35 kA at 480V AC), and frame size (225A/Frame 2) to your system's fault current and load requirements. Verify phase connection (ABC) and terminal type (standard terminals load only) match your panel configuration.
Used in
Common applications for EATONEATON Products
3G Electric supplies EATON power defense molded case circuit breakers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.