We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

DURACHILL Chiller: -20°C, 1000 W, Heated and Refrigerated, 24.6 lpm Flow Rate, Centrifugal - Lab Chillers
DURACHILLLab Chillers

DURACHILL Chiller: -20°C, 1000 W, Heated and Refrigerated, 24.6 lpm Flow Rate, Centrifugal

The DURACHILL Chiller: -20°C is a lab chiller with a minimum temperature setting of -20 °C and a temperature accuracy tolerance of +/-0.1°C. It features a centrifugal pump, an LCD display, and operates on 120V AC…

SKU 3G-OTH-366418

Also listed as: BA06A1G3310A13C · BA06A1G3 310A13C

Brand
DURACHILL
Item
Chiller: -20°C, 1000 W, Heated and Refrigerated, 24.6 lpm Flow Rate, Centrifugal
Category
Lab Chillers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

DURACHILL
Manufacturer Part Number
BA06A1G3-310A13C
Type
1000 W, Heated and Refrigerated, 24.6 lpm Flow Rate, Centrifugal
AC
120V
Voltage
120V AC
Pump Type
Centrifugal
Display Type
LCD
Min Temp Setting
-20 °C
Temperature Accuracy Tolerance
+/-0.1°C

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DURACHILL Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DURACHILL Chiller: -20°C is a lab chiller with a minimum temperature setting of -20 °C and a temperature accuracy tolerance of +/-0.1°C. It features a centrifugal pump, an LCD display, and operates on 120V AC. This unit also provides 1000 W of heating and refrigeration capacity with a flow rate of 24.6 lpm.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the DURACHILL chiller used for?

The DURACHILL chiller is used for precise temperature control in laboratory applications, such as cooling reaction vessels, condensers, and analytical instruments. It provides both heating and refrigeration with a temperature accuracy tolerance of +/-0.1°C, making it suitable for processes requiring stable low temperatures down to -20 °C.

What are the specifications of the DURACHILL chiller?

The DURACHILL chiller (MPN BA06A1G3-310A13C) operates on 120V AC, has a minimum temperature setting of -20 °C, and a temperature accuracy tolerance of +/-0.1°C. It features a centrifugal pump with a flow rate of 24.6 lpm, provides 1000 W of heating and refrigeration capacity, and includes an LCD display.

Where to buy the DURACHILL chiller worldwide?

You can source the DURACHILL chiller through 3G Electric, a global industrial equipment distributor established in 1990. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time on this lab chiller.

How to install the DURACHILL chiller?

Install the DURACHILL chiller on a level, stable surface with adequate ventilation. Connect the inlet and outlet hoses to your system using compatible fittings, then fill with the recommended coolant. Plug into a 120V AC grounded outlet, power on, and set the desired temperature via the LCD display. Refer to the manual for detailed startup procedures.

Used in

Common applications for DURACHILL
Analytical instrumentation cooling — DURACHILL chiller models with ±0.1°C stability for NMR, ICP-MS, or spectrophotometers
Laser system thermal management — DURACHILL chillers with turbine pumps for consistent flow in solid-state or CO2 lasers
Reactor jacket temperature control — DURACHILL heated/refrigerated units for jacketed glass or stainless steel reactors
Condenser cooling in rotary evaporators — DURACHILL chillers with positive displacement pumps for low-flow, high-pressure applications
Semiconductor process equipment — DURACHILL chillers with centrifugal pumps for plasma etchers or deposition tools
Material testing chambers — DURACHILL chillers providing recirculated coolant for environmental chambers or thermal cyclers

DURACHILL Products

3G Electric supplies DURACHILL lab chillers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
DURACHILL Chiller: -20°C, 2900 W, Heated and Refrigerated, 13.25 lpm Flow Rate, Turbine, 230V AC (MPN CA10A3T1-41AA1N)
DURACHILL
DURACHILL Chiller: -20°C, 2900 W, Heated and Refrigerated, 13.25 lpm Flow Rate, Turbine, 230V AC (MPN CA10A3T1-41AA1N)
THERMO SCIENTIFIC Recirculating Chiller: -10°C, 1000 W, Refrigerated, 3.6 gpm Flow Rate, 115V AC (MPN 197212010000)
THERMO SCIENTIFIC
THERMO SCIENTIFIC Recirculating Chiller: -10°C, 1000 W, Refrigerated, 3.6 gpm Flow Rate, 115V AC (MPN 197212010000)
THERMO SCIENTIFIC Recirculating Chiller: 5°C, 2500 W, Refrigerated, 3.5 gpm Flow Rate, Turbine, LED (MPN 1213C10500200200)
THERMO SCIENTIFIC
THERMO SCIENTIFIC Recirculating Chiller: 5°C, 2500 W, Refrigerated, 3.5 gpm Flow Rate, Turbine, LED (MPN 1213C10500200200)
THERMO SCIENTIFIC Recirculating Chiller: 5°C, 2500 W, Refrigerated, 4 gpm Flow Rate, 208V AC, LED (MPN 1213110500200200)
THERMO SCIENTIFIC
THERMO SCIENTIFIC Recirculating Chiller: 5°C, 2500 W, Refrigerated, 4 gpm Flow Rate, 208V AC, LED (MPN 1213110500200200)
THERMO SCIENTIFIC Recirculating Chiller: -10°C, 1000 W, Refrigerated, 2 gpm Flow Rate, 115V AC, LED (MPN 197214010000)
THERMO SCIENTIFIC
THERMO SCIENTIFIC Recirculating Chiller: -10°C, 1000 W, Refrigerated, 2 gpm Flow Rate, 115V AC, LED (MPN 197214010000)

More from DURACHILL

View all DURACHILL parts
DURACHILL Chiller: -20°C, 1740 W, Heated and Refrigerated, 13.25 lpm Flow Rate, Turbine, 120V AC (MPN CA05A1T1-41AA1N)
DURACHILL
DURACHILL Chiller: -20°C, 1740 W, Heated and Refrigerated, 13.25 lpm Flow Rate, Turbine, 120V AC (MPN CA05A1T1-41AA1N)
DURACHILL Chiller: -20°C, 1740 W, Heated and Refrigerated, 7.57 lpm Flow Rate, Positive Displacement (MPN CA05A1P1-41AA1N)
DURACHILL
DURACHILL Chiller: -20°C, 1740 W, Heated and Refrigerated, 7.57 lpm Flow Rate, Positive Displacement (MPN CA05A1P1-41AA1N)
DURACHILL Chiller: -20°C, 1400 W, Heated and Refrigerated, 7.57 lpm Flow Rate, Positive Displacement (MPN CA03A1P1-41AA1N)
DURACHILL
DURACHILL Chiller: -20°C, 1400 W, Heated and Refrigerated, 7.57 lpm Flow Rate, Positive Displacement (MPN CA03A1P1-41AA1N)
DURACHILL Chiller: -20°C, 1400 W, Heated and Refrigerated, 13.25 lpm Flow Rate, Turbine, 120V AC (MPN CA03A1T1-41AA1N)
DURACHILL
DURACHILL Chiller: -20°C, 1400 W, Heated and Refrigerated, 13.25 lpm Flow Rate, Turbine, 120V AC (MPN CA03A1T1-41AA1N)
DURACHILL Chiller: -20°C, 2900 W, Heated and Refrigerated, 13.25 lpm Flow Rate, 230V AC, +/-0.1°C (MPN CA10A3P2-41AA1N)
DURACHILL
DURACHILL Chiller: -20°C, 2900 W, Heated and Refrigerated, 13.25 lpm Flow Rate, 230V AC, +/-0.1°C (MPN CA10A3P2-41AA1N)
DURACHILL Chiller: -20°C, 850 W, Heated and Refrigerated, 7.57 lpm Flow Rate, Positive Displacement (MPN CA02A1P1-41AA1N)
DURACHILL
DURACHILL Chiller: -20°C, 850 W, Heated and Refrigerated, 7.57 lpm Flow Rate, Positive Displacement (MPN CA02A1P1-41AA1N)
DURACHILL Chiller: -10°C, 400 W, Heated and Refrigerated, 24.6 lpm Flow Rate, Centrifugal, +/-0.1°C (MPN BA05A1G3-310L13C)
DURACHILL
DURACHILL Chiller: -10°C, 400 W, Heated and Refrigerated, 24.6 lpm Flow Rate, Centrifugal, +/-0.1°C (MPN BA05A1G3-310L13C)
DURACHILL Chiller: -20°C, 850 W, Heated and Refrigerated, 13.25 lpm Flow Rate, Turbine, 120V AC, LCD (MPN CA02A1T1-41AA1N)
DURACHILL
DURACHILL Chiller: -20°C, 850 W, Heated and Refrigerated, 13.25 lpm Flow Rate, Turbine, 120V AC, LCD (MPN CA02A1T1-41AA1N)