We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

DUNGS MPA 41xx V2.0 - Automatic Burner Controls
DungsBurner control

DUNGS MPA 41xx V2.0 - Automatic Burner Controls

The DUNGS Automatic Burner Controls MPA 41xx V2.0 for forced draught or industrial single and multi-burner applications in the low or high temperature range.

SKU 3G-OTH-02883

Also listed as: MPA41XXV20 · MPA 41XX V2 0

Brand
Dungs
Item
MPA 41xx V2.0 - Automatic Burner Controls
Category
Burner control
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Datasheet Content

[{"filename":"3G-OTH-02883-pulse-firing_product-handbook_en_301459.pdf","text":"Manual\n MPA 41xx PF V2.0\n\n\n\n\n Edition: 2023.07\n\n\n\n\n Printed in Germany • Edition 2023.07 • Nr. 301459\n\n\n\n\n1 … 138\n No. 301 459 - GB\n\fTable of contents\n\n\nTarget group / warnings. ..........................................................................................................................................3\nIntended use, risks in case of misuse. ...................................................................................................................4\nApproval overview. ...................................................................................................................................................5\nSystem description / variants / accessories..........................................................................................................6\nTechnical data. ..........................................................................................................................................................7\nConnection diagram............................................................................................................................................. 8-9\nTechnical data for outputs / inputs. ................................................................................................................ 10-12\nFlame monitoring / connection of flame detector device............................................................................. 13-14\nInstallation of MPA 411x PF. ..................................................................................................................................15\nDimensions MPA 411x PF. .....................................................................................................................................16\nInstallation of MPA 412x PF. ..................................................................................................................................17\nDimensions MPA 412x PF. .....................................................................................................................................17\nDisplay AM 41..........................................................................................................................................................18\nDescription of functions\nUnlock function\nEnhanced unlock\nAccess level.............................................................................................................................................................19\nDescription of functions\nGas valves\nMultifunction inputs\nParameter mode\nAutomatic / parameter mode function switch......................................................................................................20\nFlow diagram..................................................................................................................................................... 21-25\nConfiguration of multifunction inputs / function outputs............................................................................. 26-27\nState description............................................................................................................................................... 28-33\nParameters / parameter changes..........................................................................................................................34\nParameters / description of parameters......................................................................................................... 35-49\nParameters / factory settings. ......................................................................................................................... 50-52\nStatus information. ........................................................................................................................................... 53-54\nMPA 4114 / version without display. ............................................................................................................... 55-56\nMPA 41x2 / version with display............................................................................................................................57\nMPA 41x2 / overview of display modes. ...............................................................................................................58\nMPA 41x2 / display..................................................................................................................................................59\nMPA 41x2 / operating display. ...............................................................................................................................60\nMPA 41x2 / operating display additional information / setting bus address....................................................61\nMPA 41x2 / information display....................................................................................................................... 62-63\nMPA 41x2 / error display. .......................................................................................................................................64\nMPA 41x2 / error memory display. ........................................................................................................................65\nMPA 41x2 / parameter display. ........................................................................................................................ 66-72\nMPA 41x2 / reset display. ................................................................................................................................. 73-74\nMPA 41x2 / shutdown function..............................................................................................................................75\nMPA 41xx errors without error ID..........................................................................................................................76\nMPA 41xx errors from the basic system......................................................................................................... 77-78\nMPA 41xx errors from the extension function................................................................................................ 79-81\nEMC-compliant version..........................................................................................................................................82\nSetting of field bus address, bus termination......................................................................................................83\nProfibus, Modbus, shutter control MPA 41xx EM 2/4.................................................................................... 84-99\nExtension module MPA 41xx EM 2/6........................................................................................................... 100-118\nFlame detector device.................................................................................................................................. 119-120\nUV 41 (HE). .................................................................................................................................................... 121-122\nUV 42 . .......................................................................................................................................................... 123-124\nFLW 20xx UV.................................................................................................................................................. 125-127\n\n\n\n\n Printed in Germany • Edition 2023.07 • Nr. 301459\nFLW 10xx IR................................................................................................................................................... 128-130\nFLW 41 I ......................................................................................................................................................... 131-132\nIgnition transformers.................................................................................................................................... 133-135\nVisionBox.............................................................................................................................................................. 136\n\n\n\n\n 2 … 138\n\f Product manual\n\n MPA 41xx PF V2.0\n\n\n Target group\n\n The target group for this manual is specialised gas\n safety and control technology personnel, qualified\n persons or the persons instructed by them.\n They can assess the work assigned to them as well as\n potential hazards on the basis of their technical training,\n knowledge and experiences, as well as knowledge of the\n relevant regulations. Only they are permitted to install, Place this user manual in an easily viewable\n start up, adjust and service the equipment in compliance location in the installation room! Perform work\n with the accepted rules of industrial safety. only after reading the safety instructions in\n this user manual.\n\n\n\n\n Warnings\n General warnings\n\n\n The accepted rules of industrial safety Protection must be ensured against\n and the accident prevention regula- environmental and climatic influences\n tions must be followed, taking safety (corrosion, snow, icing, moisture\n measures to ensure the protection (e.g. due to condensation), mould,\n of persons if necessary. UV radiation, harmful insects and\n toxic, corrosive solutions / liquids\n Set all settings and setting values only (e.g. cutting / cooling fluids)). Appro-\n in accordance with the user manual priate safety measures must be taken\n for the connected machine. depending on the installation location.\n\n\n\n Never perform work when gas pres- The device may…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DUNGS Automatic Burner Controls MPA 41xx V2.0 for forced draught or industrial single and multi-burner applications in the low or high temperature range.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the DUNGS MPA 41xx V2.0 used for?

The DUNGS MPA 41xx V2.0 is an automatic burner control for forced draught or industrial single and multi-burner applications. It is suitable for low or high temperature ranges, providing flame monitoring and safety sequencing in commercial and industrial heating systems.

What are the specifications of the DUNGS MPA 41xx V2.0?

The DUNGS MPA 41xx V2.0 burner control includes models MPA 411x PF and MPA 412x PF. It features flame detector device connection, multifunction gas valve control, and an AM 41 display. Technical data covers outputs, inputs, and connection diagrams as per the manufacturer datasheet.

Where to buy the DUNGS MPA 41xx V2.0 in Singapore?

3G Electric supplies the DUNGS MPA 41xx V2.0 automatic burner controls to Singapore. We handle sourcing, logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this DUNGS burner control for your industrial application.

How to install the DUNGS MPA 41xx V2.0?

Installation of the DUNGS MPA 41xx V2.0 must follow the manufacturer manual. For MPA 411x PF, refer to the specific installation and dimension diagrams. Ensure proper connection of flame detector and gas valves. Always comply with local safety regulations and use qualified technicians.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs burner control. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Base for MA 40-50-55
Pactrol
Base for MA 40-50-55
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
Fireye
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
Satronic
Satronic
Base DGAI
Base for MA 20
Pactrol
Base for MA 20
Satronic
Satronic
Relay DMG 972-N MOD.01
Satronic
Satronic
Relay DMG 972-N MOD.03

More from Dungs

View all Dungs parts
Dungs
Dungs
DUNGS FLW 2x UV - UV-Flame Sensors
Dungs
Dungs
DUNGS FLW 1x IR - IR-Flame Sensors