We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

3G Electric
DRAEGER CH28301 Phosgene Gas Detection Tube (10 pk) - Gas Detection Tubes For Use In DRAEGER Accuro Pumps
DRAEGERGas Detection Tubes For Use In DRAEGER Accuro Pumps

DRAEGER CH28301 Phosgene Gas Detection Tube (10 pk)

The DRAEGER Detector Tube for Accuro pumps is a gas detection tube designed to detect phosgene (COCl2) with a measurement range of 0.25 to 5 ppm. Supplied in packs of 10 (MPN CH28301), this tube is used exclusively…

SKU 3G-OTH-548150

Also listed as: CH 28301 · CH-28301

Brand
DRAEGER
Item
CH28301 Phosgene Gas Detection Tube
Part Number
CH28301
Category
Gas Detection Tubes For Use In DRAEGER Accuro Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

DRAEGER
Manufacturer Part Number
CH28301
Type
COCl2, Gas Detection Tube, Phosgene ( COCl2 ), 10 PK
Gas Detected
Phosgene
Measurement Range
0.25 to 5 ppm

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DRAEGER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DRAEGER Detector Tube for Accuro pumps is a gas detection tube designed to detect phosgene (COCl2) with a measurement range of 0.25 to 5 ppm. Supplied in packs of 10 (MPN CH28301), this tube is used exclusively with DRAEGER Accuro pumps for reliable gas sampling.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the DRAEGER Accuro phosgene detector tube used for?

The DRAEGER Accuro phosgene detector tube (CH28301) is used for spot-checking ambient air for phosgene gas (COCl2) in industrial environments such as chemical processing, water treatment, and emergency response. It provides a direct-read measurement from 0.25 to 5 ppm when used with a DRAEGER Accuro bellows pump.

What are the specifications of the DRAEGER CH28301 gas detection tube?

The DRAEGER CH28301 is a phosgene (COCl2) detection tube with a measurement range of 0.25 to 5 ppm. It is supplied in packs of 10 and is designed exclusively for use with DRAEGER Accuro manual pumps. The tube provides a colorimetric indication for on-the-spot gas analysis without electronic calibration.

Where to buy DRAEGER Accuro phosgene detector tubes worldwide?

3G Electric supplies DRAEGER Accuro phosgene detector tubes (CH28301) to customers worldwide. As a global industrial sourcing partner, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this and other DRAEGER gas detection consumables.

How to use the DRAEGER Accuro tube for phosgene detection?

To use the DRAEGER Accuro phosgene tube, break off both tips of the tube, insert it into the Accuro pump with the arrow pointing toward the pump, and perform the specified number of pump strokes per the tube instructions. Read the color change length against the printed scale. Always follow the manufacturer's safety guidelines for confined-space or emergency use.

Not sure this is the right part? Photo-identify it

DRAEGER Products

3G Electric supplies DRAEGER gas detection tubes for use in draeger accuro pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from DRAEGER

View all DRAEGER parts
Gas detection tube for use with DRAEGER Accuro pumps. Detects ethylene (C2H4) in a measurement range of 0.2 to 5 ppm. Supplied in a pack of 10 tubes. Suitable for spot-checking ethylene concentrations in industrial environments such as chemical processing or refrigeration
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects ethylene (C2H4) in a measurement range of 0.2 to 5 ppm. Supplied in a pack of 10 tubes. Suitable for spot-checking ethylene concentrations in industrial environments such as chemical processing or refrigeration
Gas detection tube for use with DRAEGER Accuro pumps. Detects oil mist in the range of 1 to 10 mg/m3. Maximum operating temperature 86°F. Pack of 10 tubes. Suitable for industrial air monitoring in environments where oil mist may be present
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects oil mist in the range of 1 to 10 mg/m3. Maximum operating temperature 86°F. Pack of 10 tubes. Suitable for industrial air monitoring in environments where oil mist may be present
Gas detection tube for use with DRAEGER Accuro pumps. Detects methylene chloride (CH2Cl2) in air over a measurement range of 20 to 200 ppm. Maximum operating temperature 86°F. Pack of 10 tubes. Suitable for spot-checking airborne solvent concentrations in industrial environments
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects methylene chloride (CH2Cl2) in air over a measurement range of 20 to 200 ppm. Maximum operating temperature 86°F. Pack of 10 tubes. Suitable for spot-checking airborne solvent concentrations in industrial environments
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps. Each tube detects diethyl ether ((C2H5)2O) within a measurement range of 100 to 4,000 ppm and operates at temperatures up to 104°F. Suitable for industrial safety monitoring where diethyl ether may be present
DRAEGER
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps. Each tube detects diethyl ether ((C2H5)2O) within a measurement range of 100 to 4,000 ppm and operates at temperatures up to 104°F. Suitable for industrial safety monitoring where diethyl ether may be present
Gas detection tube for use with DRAEGER Accuro pumps. Detects hydrochloric acid (HCl) in the range of 1 to 10 ppm. Supplied in a pack of 10 tubes. Suitable for on-the-spot measurement of HCl concentrations in industrial environments
DRAEGER
Gas detection tube for use with DRAEGER Accuro pumps. Detects hydrochloric acid (HCl) in the range of 1 to 10 ppm. Supplied in a pack of 10 tubes. Suitable for on-the-spot measurement of HCl concentrations in industrial environments
DRAEGER CS2 gas detection tube for use with Accuro pumps. Detects carbon disulfide (CS2) in the range of 3 to 95 ppm. Pack of 10 tubes. Suitable for industrial safety monitoring in environments where carbon disulfide may be present
DRAEGER
DRAEGER CS2 gas detection tube for use with Accuro pumps. Detects carbon disulfide (CS2) in the range of 3 to 95 ppm. Pack of 10 tubes. Suitable for industrial safety monitoring in environments where carbon disulfide may be present
Qualitative gas detection tube for use with DRAEGER Accuro pumps. Detects Hydrogen Acid with a 3-minute measurement time. Maximum operating temperature 86°F. Supplied in a 10-pack
DRAEGER
Qualitative gas detection tube for use with DRAEGER Accuro pumps. Detects Hydrogen Acid with a 3-minute measurement time. Maximum operating temperature 86°F. Supplied in a 10-pack
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps to measure hydrogen sulfide (H2S) concentrations in ambient air. Each tube provides a colorimetric indication over a measurement range of 2 to 60 ppm. Typical applications include monitoring toxic gas exposure in industrial environments such as refineries, chemical plants, and confined spaces
DRAEGER
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps to measure hydrogen sulfide (H2S) concentrations in ambient air. Each tube provides a colorimetric indication over a measurement range of 2 to 60 ppm. Typical applications include monitoring toxic gas exposure in industrial environments such as refineries, chemical plants, and confined spaces

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first