We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

DOSTMANN CT376DIG Multi-Channel Meter for Type T Thermocouple, -148°F to 752°F - Multi-Channel Meters without Data Output
DOSTMANNMulti-Channel Meters without Data Output

DOSTMANN CT376DIG Multi-Channel Meter for Type T Thermocouple, -148°F to 752°F

The DOSTMANN CT376DIG is a multi-channel meter without data output, designed for use with Type T thermocouples. It measures temperatures from -148°F to 752°F with an accuracy of ±0.05% of reading ±0.1°C.

SKU 3G-OTH-177827

Brand
DOSTMANN
Item
CT376DIG Multi-Channel Meter for Type T Thermocouple, -148°F to 752°F
Category
Multi-Channel Meters without Data Output
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

DOSTMANN
Manufacturer Part Number
CT376DIG
Type
For Type T Thermocouple Type, -148°F to 752°F
Accuracy
±0.05 % of Reading ±0.1 °C
Thermocouple Temperature Fahrenheit - Maximum
752 °F

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DOSTMANN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DOSTMANN CT376DIG is a multi-channel meter without data output, designed for use with Type T thermocouples. It measures temperatures from -148°F to 752°F with an accuracy of ±0.05% of reading ±0.1°C.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the DOSTMANN CT376DIG thermocouple thermometer used for?

The DOSTMANN CT376DIG is a multi-channel meter for Type T thermocouples, measuring from -148°F to 752°F. It is used in industrial process monitoring, HVAC, and laboratory applications where precise temperature tracking across multiple points is required without data logging.

What are the specifications of the DOSTMANN CT376DIG?

The DOSTMANN CT376DIG is a multi-channel meter for Type T thermocouples, with a temperature range of -148°F to 752°F and accuracy of ±0.05% of reading ±0.1°C. It has no data output. The maximum Fahrenheit reading is 752 °F.

Where to buy the DOSTMANN CT376DIG worldwide?

3G Electric supplies the DOSTMANN CT376DIG worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this multi-channel thermocouple thermometer.

How to select a thermocouple thermometer for Type T probes?

When selecting a thermocouple thermometer for Type T probes, match the meter's temperature range to your process—the DOSTMANN CT376DIG covers -148°F to 752°F. Ensure accuracy meets your tolerance; this model offers ±0.05% of reading ±0.1°C. Multi-channel capability allows simultaneous monitoring of multiple points.

Used in

Common applications for DOSTMANN
Industrial burner flame temperature monitoring — DOSTMANN CT376DIG thermocouple thermometer with Type K probe
HVAC system diagnostics — DOSTMANN thermocouple thermometer for supply and return air temperature differentials
Pump motor bearing temperature checks — DOSTMANN CT376DIG with surface-mount thermocouple probe
Gas control valve validation — DOSTMANN thermometer for verifying preheat and process gas temperatures
Laboratory oven calibration — DOSTMANN multi-channel thermometer with Type T thermocouples for uniformity testing
Refrigeration system troubleshooting — DOSTMANN thermometer for evaporator and condenser coil temperature measurement

DOSTMANN Products

3G Electric supplies DOSTMANN multi-channel meters without data output. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Single-channel RTD meter for temperature measurement without data output. Measures from -148°F to 572°F with accuracy of +/-0.4°C. Includes Min/Max temperature testing functions for monitoring extremes in industrial processes
THERMCO
Single-channel RTD meter for temperature measurement without data output. Measures from -148°F to 572°F with accuracy of +/-0.4°C. Includes Min/Max temperature testing functions for monitoring extremes in industrial processes
Multi-channel meter with cabled data output for thermocouple temperature measurement. Accuracy ±0.4% + 1.8°F/1°C. Type T thermocouple maximum 752°F. Suitable for industrial maintenance, HVAC, and process control applications
REED INSTRUMENTS
Multi-channel meter with cabled data output for thermocouple temperature measurement. Accuracy ±0.4% + 1.8°F/1°C. Type T thermocouple maximum 752°F. Suitable for industrial maintenance, HVAC, and process control applications
Multi-channel meter for Type E, J, K, R, S, and T thermocouples. Accuracy ±0.4% + 1.8°F/1°C for Type J, K, E, T, and Pt100 RTD. Maximum temperature 752°F for Type T. Suitable for industrial process monitoring, HVAC diagnostics, and laboratory testing
EXTECH
Multi-channel meter for Type E, J, K, R, S, and T thermocouples. Accuracy ±0.4% + 1.8°F/1°C for Type J, K, E, T, and Pt100 RTD. Maximum temperature 752°F for Type T. Suitable for industrial process monitoring, HVAC diagnostics, and laboratory testing
Multi-channel meter accepting Type E, J, K, R, S, and T thermocouples. Accuracy ±0.5 % + 2 °F/1 °C for Type R and S. Maximum temperature 752 °F for Type T. Includes cabled data output for monitoring and logging in industrial, laboratory, and HVAC applications
EXTECH
Multi-channel meter accepting Type E, J, K, R, S, and T thermocouples. Accuracy ±0.5 % + 2 °F/1 °C for Type R and S. Maximum temperature 752 °F for Type T. Includes cabled data output for monitoring and logging in industrial, laboratory, and HVAC applications
This thermocouple meter accepts Type K thermocouples and measures from -58°F to 1,832°F with an accuracy of ±0.9 °F + 0.3% of reading (-50 to 1,832 °F). Two channels allow differential temperature measurement. Bluetooth connectivity enables wireless data output for remote monitoring
TESTO
This thermocouple meter accepts Type K thermocouples and measures from -58°F to 1,832°F with an accuracy of ±0.9 °F + 0.3% of reading (-50 to 1,832 °F). Two channels allow differential temperature measurement. Bluetooth connectivity enables wireless data output for remote monitoring
Single-input RTD meter for temperature measurement from -328 to 1562°F. Accuracy is ±4°C (±2°F) from -328 to -148°F, ±0.4°F (±0.2°C) from -148 to 392°F, and ±4°F (±2°C) from 392 to 1562°F. Includes Min/Max temperature testing functions. Suitable for industrial process monitoring, HVAC, and laboratory applications
DIGI-SENSE
Single-input RTD meter for temperature measurement from -328 to 1562°F. Accuracy is ±4°C (±2°F) from -328 to -148°F, ±0.4°F (±0.2°C) from -148 to 392°F, and ±4°F (±2°C) from 392 to 1562°F. Includes Min/Max temperature testing functions. Suitable for industrial process monitoring, HVAC, and laboratory applications

More from DOSTMANN

View all DOSTMANN parts