Dongan 33-100-HLK, single-phase control transformer, 0.100 kVA
The Dongan 3G-OTH-03395 is a single-phase control transformer from the Series 33 Control line. It is rated at 0.100 kVA with a primary voltage of 240 x 480 V and a secondary voltage of 24 V, operating at 50/60 Hz…
SKU 3G-OTH-03395
Also listed as: 33100HLK · 33 100 HLK
Local availability & support — the Philippines
- Delivery
- 5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
- Payment
- Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
- Ships to
- Manila, Quezon City, Cebu, Davao, Batangas
Need installation or engineering help?
Ask a question
Product Description
The Dongan 3G-OTH-03395 is a single-phase control transformer from the Series 33 Control line. It is rated at 0.100 kVA with a primary voltage of 240 x 480 V and a secondary voltage of 24 V, operating at 50/60 Hz. This compact unit weighs 4 lb and measures 3.63 x 3.38 x 2.81 inches.
Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.
Frequently Asked Questions
What is the Dongan 3G-OTH-03395 control transformer used for?
The Dongan 3G-OTH-03395 is a single-phase control transformer designed to step down primary voltage (240 x 480 V) to a 24 V secondary for industrial control circuits, such as relays, contactors, and PLCs. It is commonly used in machinery and automation systems requiring reliable low-voltage power.
What are the specifications of the Dongan 3G-OTH-03395?
The Dongan 3G-OTH-03395 is a single-phase control transformer rated at 0.100 kVA, with a primary voltage of 240 x 480 V and a secondary voltage of 24 V. It operates at 50/60 Hz, weighs 4 lb, and measures 3.63 x 3.38 x 2.81 inches. It is part of the Series 33 Control line.
Where to buy the Dongan 3G-OTH-03395 in Singapore?
You can source the Dongan 3G-OTH-03395 through 3G Electric in Singapore. We provide procurement, logistics, customs clearance, and delivery for this control transformer. Contact us for pricing and lead time; we do not hold stock but can order and supply it to your location.
How to install the Dongan 3G-OTH-03395 control transformer?
To install the Dongan 3G-OTH-03395, mount it securely on a panel or enclosure using the provided mounting holes. Connect the primary winding to the appropriate 240 V or 480 V supply, and the secondary to the 24 V control circuit. Ensure proper fusing per local codes and verify connections before energizing.
Used in
Common applications for DonganDongan Products
3G Electric supplies Dongan control transformer. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.
You might also need
Related products
- SCHNEIDER This SCHNEIDER non-reversing IEC contactor features 3 poles with 3 normally open main contacts rated at 25 A. The coil accepts dual voltage 120V AC/240V AC. It is used for switching three-phase motors and other power circuits in motor control, lighting, and HVAC applications
- SCHNEIDER Non-reversing IEC contactor with 3 poles and 3 normally open contacts, rated 50 A. Coil voltage 120V AC/240V AC. No integrated surge suppression. Used for switching electrical loads in motor control and automation systems such as conveyors, pumps, and compressors
- SCHNEIDER IEC magnetic contactor for switching electrical loads in motor control, lighting, and HVAC systems. Features 3 poles with 3 normally open contacts rated at 32 A. Coil operates on 120V AC or 240V AC. No integrated surge suppression
- SCHNEIDER SCHNEIDER non-reversing IEC contactor with 3 poles and 3 normally open (NO) contacts, rated at 40 A. Coil voltage is 120V AC/240V AC. No integrated surge suppression. Suitable for switching motors, lighting, and other loads in industrial and commercial applications
- SCHNEIDER This 3-pole non-reversing IEC contactor from Schneider is rated for 32 A and features three normally open (3NO) main contacts. It is designed for switching three-phase loads such as motors, lighting, and HVAC equipment. The coil operates at 48V AC at 60 Hz; no integrated surge suppression is included
- SCHNEIDER SCHNEIDER LC1D38KUE is a non-reversing IEC contactor with 3 poles and 3 normally open (NO) contacts, rated at 38 A. The coil operates on 120V AC or 240V AC. It is used for switching electrical loads in motor control, lighting, and power distribution systems. This unit does not include integrated surge suppression