The DIGI-SENSE Single-Input RTD Thermometer (MPN 9142807) is a 1-channel RTD meter without data output, covering a temperature range of -328°F to 1,562°F. It offers accuracy of ±4°C (±2°F) from –328 to –148°F, ±0.4°F…

SKU 3G-OTH-179992

Brand
DIGI-SENSE
Item
Single-Input RTD Thermometer, -328 to 1562°F, 1 Channel
Part Number
9142807
Category
RTD Meters without Data Output
Available to Order
Also known as:9142807DIGI-SENSE
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

DIGI-SENSE
Manufacturer Part Number
9142807
Accuracy
±4°C (±2°F) from –328 to –148°F (–200 to –100°C), ±0.4°F (±0.2°C) from –148 to 392°F (–99.9 to 199.9°C), ±4°F (±2°C) from 392 to 1562°F (200 to 850°C)
Testing Functions
Min/Max Temperature

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DIGI-SENSE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DIGI-SENSE Single-Input RTD Thermometer (MPN 9142807) is a 1-channel RTD meter without data output, covering a temperature range of -328°F to 1,562°F. It offers accuracy of ±4°C (±2°F) from –328 to –148°F, ±0.4°F (±0.2°C) from –148 to 392°F, and ±4°F (±2°C) from 392 to 1,562°F. The device includes Min/Max Temperature testing functions.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the DIGI-SENSE Single-Input RTD Thermometer used for?

The DIGI-SENSE Single-Input RTD Thermometer is used for precise temperature measurement in industrial processes, HVAC, and laboratory applications. It monitors temperatures from -328°F to 1,562°F with Min/Max tracking, making it suitable for quality control and equipment troubleshooting across manufacturing and maintenance environments.

What are the specifications of the DIGI-SENSE Single-Input RTD Thermometer?

The DIGI-SENSE RTD Thermometer (MPN 9142807) has 1 channel, a range of -328°F to 1,562°F, and accuracy of ±4°C (±2°F) from –328 to –148°F, ±0.4°F (±0.2°C) from –148 to 392°F, and ±4°F (±2°C) from 392 to 1,562°F. It includes Min/Max Temperature testing functions.

Where to buy the DIGI-SENSE Single-Input RTD Thermometer worldwide?

3G Electric supplies the DIGI-SENSE Single-Input RTD Thermometer worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to deliver this instrument to your facility. Contact us for availability and lead time on this DIGI-SENSE model.

How to select the right RTD thermometer for industrial use?

Select an RTD thermometer based on your temperature range, accuracy needs, and probe compatibility. The DIGI-SENSE model covers -328°F to 1,562°F with three accuracy tiers, ideal for broad industrial monitoring. Ensure the probe type matches your application, and consider Min/Max logging for trend analysis.

Used in

Common applications for DIGI-SENSE
HVAC system diagnostics — DIGI-SENSE thermocouple meter (model 9142803) for checking duct temperatures and refrigerant lines.
Process control in chemical plants — DIGI-SENSE RTD datalogger (model 9142808) for monitoring reactor vessel temperatures.
Food safety verification — DIGI-SENSE thermistor thermometer (model 9142805) for spot-checking cooking and holding temperatures.
Laboratory research — DIGI-SENSE 12-channel scanning thermocouple datalogger (model 9200002) for multi-point temperature profiling.
Equipment maintenance — DIGI-SENSE single-input RTD thermometer (model 9142807) for bearing and motor temperature checks.
Environmental monitoring — DIGI-SENSE thermistor datalogger (model 20250-93) for long-term temperature logging in storage areas.
Not sure this is the right part? Photo-identify it

DIGI-SENSE Products

3G Electric supplies DIGI-SENSE rtd meters without data output. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from DIGI-SENSE

View all DIGI-SENSE parts

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first