The DAYTON Tubeaxial Fan: Flammable Vapor is an unassembled, Class I Group C and D hazardous-location belt-drive fan with a spark-resistant Type B construction. It features a 3-phase, 208-230/460V AC motor with a…

SKU 3G-OTH-77658

Brand
Dayton
Item
Flammable Vapor Belt-Drive Fan with Drive
Category
Flammable Vapor Belt-Drive Fans with Drive
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Dayton
Type
4,039 cfm @ 0.000 in SP, 3/4 hp
AC
208-230/460V
Blade
18 in
Assembly
Unassembled
Motor Type
3-Phase
Motor Enclosure
Totally Enclosed Fan Cooled
Number of Speeds
1
Nameplate Voltage
208-230/460V AC
Mounting Orientation
Horizontal
Includes Drive Package
Yes
Airflow @ 0.000 in SP - Range
0 to 9,999 cfm
Hazardous Location Specification
Class I Group C
Spark Resistant Construction Type
B

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DAYTON Tubeaxial Fan: Flammable Vapor is an unassembled, Class I Group C and D hazardous-location belt-drive fan with a spark-resistant Type B construction. It features a 3-phase, 208-230/460V AC motor with a totally enclosed fan-cooled enclosure, a single speed, and a horizontal mounting orientation. The fan delivers 4,039 cfm at 0.000 in SP with an 18-inch blade and includes a drive package.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the DAYTON Tubeaxial Fan used for?

The DAYTON Tubeaxial Fan is used for ventilating flammable vapor environments in hazardous locations classified as Class I Groups C and D. It is suitable for industrial settings such as chemical plants, refineries, and paint booths where explosive gases or vapors may be present.

What are the specifications of the DAYTON fan?

The DAYTON is a flammable vapor belt-drive tubeaxial fan with an 18-inch blade delivering 4,039 cfm at 0.000 in SP. It has a 3-phase, 208-230/460V AC motor, 3/4 hp, totally enclosed fan-cooled, single speed, horizontal mounting, and spark-resistant Type B construction. It includes a drive package and is unassembled.

Where to buy the DAYTON fan worldwide?

You can source the DAYTON fan worldwide through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time; we supply genuine DAYTON components for hazardous-location ventilation needs.

How to install the DAYTON tubeaxial fan?

Install the DAYTON fan horizontally in a Class I Group C or D area. Assemble the belt-drive components per the included drive package instructions. Ensure proper electrical connection to 208-230/460V AC, 3-phase power. Use certified conduit seals and follow local codes for hazardous locations. Always consult a qualified electrician.

Used in

Common applications for Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Products

3G Electric supplies Dayton flammable vapor belt-drive fans with drive. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This belt-drive fan is designed for horizontal mounting in hazardous locations containing flammable vapors, such as Class I Group C and D environments. It features a 3-phase, totally enclosed fan cooled motor rated at 1/2 hp and 208-230/460V AC, delivering 3,494 cfm at 0.000 in SP. The unassembled unit includes a drive package and has spark-resistant construction type B
Dayton
This belt-drive fan is designed for horizontal mounting in hazardous locations containing flammable vapors, such as Class I Group C and D environments. It features a 3-phase, totally enclosed fan cooled motor rated at 1/2 hp and 208-230/460V AC, delivering 3,494 cfm at 0.000 in SP. The unassembled unit includes a drive package and has spark-resistant construction type B
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Groups C and D. It features Type B spark-resistant construction, a 21-inch blade delivering 4042 cfm at 0.000 in SP, and a 1/2 hp, 3-phase, TEFC motor with single-speed operation at 208-230/460V AC. The vertical-mount unit includes a drive package for installation. Typical applications include ventilation in areas where flammable vapors may be present
Dayton
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Groups C and D. It features Type B spark-resistant construction, a 21-inch blade delivering 4042 cfm at 0.000 in SP, and a 1/2 hp, 3-phase, TEFC motor with single-speed operation at 208-230/460V AC. The vertical-mount unit includes a drive package for installation. Typical applications include ventilation in areas where flammable vapors may be present
This belt-drive fan is designed for hazardous locations where flammable vapors may be present, featuring Type B spark-resistant construction and Class I Group C compliance. It delivers 5,298 cfm at 0.000 in SP with an 18-inch blade, powered by a 1-speed capacitor-start capacitor-run motor in a totally enclosed fan-cooled enclosure. The unassembled unit includes a drive package and is intended for horizontal mounting, operating on 208-230V AC single-phase power
Dayton
This belt-drive fan is designed for hazardous locations where flammable vapors may be present, featuring Type B spark-resistant construction and Class I Group C compliance. It delivers 5,298 cfm at 0.000 in SP with an 18-inch blade, powered by a 1-speed capacitor-start capacitor-run motor in a totally enclosed fan-cooled enclosure. The unassembled unit includes a drive package and is intended for horizontal mounting, operating on 208-230V AC single-phase power
This Class I Group C hazardous-location belt-drive fan features Type B spark-resistant construction for ventilation in areas with flammable vapors. The unassembled unit includes a drive package, has a 16-inch blade delivering 2727 cfm at 0.000 in SP, and operates on 208-230/460V AC three-phase power with a 1/2 hp totally enclosed fan-cooled motor. Designed for vertical mounting
Dayton
This Class I Group C hazardous-location belt-drive fan features Type B spark-resistant construction for ventilation in areas with flammable vapors. The unassembled unit includes a drive package, has a 16-inch blade delivering 2727 cfm at 0.000 in SP, and operates on 208-230/460V AC three-phase power with a 1/2 hp totally enclosed fan-cooled motor. Designed for vertical mounting
Belt-drive tubeaxial fan for flammable vapor exhaust in hazardous locations. Class I Groups C and D, Type B spark-resistant construction. 18 in blade delivers 3,230 cfm at 0.000 in SP. 230/460V AC, 3-phase, totally enclosed nonventilated motor, single speed. Includes drive package; unassembled for horizontal mounting
Dayton
Belt-drive tubeaxial fan for flammable vapor exhaust in hazardous locations. Class I Groups C and D, Type B spark-resistant construction. 18 in blade delivers 3,230 cfm at 0.000 in SP. 230/460V AC, 3-phase, totally enclosed nonventilated motor, single speed. Includes drive package; unassembled for horizontal mounting
This belt-drive fan is designed for hazardous locations classified as Class I Group C, with Type B spark-resistant construction. It delivers 12,520 cfm at 0.000 in SP, powered by a 1 hp, 115/208-230V AC capacitor-start capacitor-run motor with a totally enclosed fan-cooled enclosure. The unassembled unit includes a drive package and is intended for vertical mounting. Typical applications include ventilation in areas where flammable vapors may be present
Dayton
This belt-drive fan is designed for hazardous locations classified as Class I Group C, with Type B spark-resistant construction. It delivers 12,520 cfm at 0.000 in SP, powered by a 1 hp, 115/208-230V AC capacitor-start capacitor-run motor with a totally enclosed fan-cooled enclosure. The unassembled unit includes a drive package and is intended for vertical mounting. Typical applications include ventilation in areas where flammable vapors may be present

More from Dayton

View all Dayton parts
This belt-drive fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It features an 11-inch wheel, delivers 1526 cfm, and includes a drive pack. The totally enclosed nonventilated motor operates at 230/460V AC single-speed. Unassembled with a square base for roof mounting
Dayton
This belt-drive fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It features an 11-inch wheel, delivers 1526 cfm, and includes a drive pack. The totally enclosed nonventilated motor operates at 230/460V AC single-speed. Unassembled with a square base for roof mounting
This unassembled tubeaxial fan is designed for Class I Group C hazardous locations. It delivers 1,904 cfm at 0.000 in SP with a 12-inch blade, powered by a 1/2 hp, 3-phase, totally enclosed fan-cooled motor (208-230/460V AC, single speed). Includes a drive package, B-type spark-resistant construction, and is intended for horizontal mounting. Typical applications include ventilation of areas where flammable vapors or gases may be present
Dayton
This unassembled tubeaxial fan is designed for Class I Group C hazardous locations. It delivers 1,904 cfm at 0.000 in SP with a 12-inch blade, powered by a 1/2 hp, 3-phase, totally enclosed fan-cooled motor (208-230/460V AC, single speed). Includes a drive package, B-type spark-resistant construction, and is intended for horizontal mounting. Typical applications include ventilation of areas where flammable vapors or gases may be present
This belt-drive fan is designed for horizontal mounting and intended for use in hazardous locations classified as Class I Group C and D. It features a 60-inch blade, delivers 50,567 cfm at 0.000 in static pressure, and operates on 230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unassembled unit includes a drive package and has spark-resistant construction Type B
Dayton
This belt-drive fan is designed for horizontal mounting and intended for use in hazardous locations classified as Class I Group C and D. It features a 60-inch blade, delivers 50,567 cfm at 0.000 in static pressure, and operates on 230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unassembled unit includes a drive package and has spark-resistant construction Type B
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 24 in blade, delivers 10,310 cfm at 0.000 in SP, and is powered by a 3-phase, 230/460V AC motor with a totally enclosed fan-cooled enclosure. Rated for Class I Group C hazardous locations with spark-resistant construction Type B, it is intended for vertical mounting and includes a drive package
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 24 in blade, delivers 10,310 cfm at 0.000 in SP, and is powered by a 3-phase, 230/460V AC motor with a totally enclosed fan-cooled enclosure. Rated for Class I Group C hazardous locations with spark-resistant construction Type B, it is intended for vertical mounting and includes a drive package
This belt-drive fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E & F. It delivers 2,839 cfm with an 18 1/2 in wheel and includes a drive package. The fan is unassembled, mounts on a square roof base, and operates with a standard-efficiency totally enclosed nonventilated motor at 115/208-230V AC, single speed
Dayton
This belt-drive fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E & F. It delivers 2,839 cfm with an 18 1/2 in wheel and includes a drive package. The fan is unassembled, mounts on a square roof base, and operates with a standard-efficiency totally enclosed nonventilated motor at 115/208-230V AC, single speed
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Group C and D. It features a 42-inch blade delivering 25,320 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, totally enclosed fan-cooled motor. The unit includes a drive package, mounts horizontally, and has spark-resistant construction Type B for flammable vapor applications
Dayton
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Group C and D. It features a 42-inch blade delivering 25,320 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, totally enclosed fan-cooled motor. The unit includes a drive package, mounts horizontally, and has spark-resistant construction Type B for flammable vapor applications
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
This unassembled flammable vapor belt-drive fan is designed for horizontal mounting and includes a drive package. It features a 60-inch blade, a 3-phase totally enclosed nonventilated motor rated at 230/460V AC, and delivers 45,933 cfm at 0.000 in SP. Suitable for Class I Group C hazardous locations with spark-resistant construction type B
Dayton
This unassembled flammable vapor belt-drive fan is designed for horizontal mounting and includes a drive package. It features a 60-inch blade, a 3-phase totally enclosed nonventilated motor rated at 230/460V AC, and delivers 45,933 cfm at 0.000 in SP. Suitable for Class I Group C hazardous locations with spark-resistant construction type B