We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Dayton Type K Thermocouple, ±1.1°C Accuracy, 12 in FEP Cable, 20 AWG - Thermocouples for Gas Applications
DaytonThermocouples for Gas Applications

Dayton Type K Thermocouple, ±1.1°C Accuracy, 12 in FEP Cable, 20 AWG

The DAYTON Temperature Probe (SKU 3G-OTH-179150) is a Type K thermocouple for gas applications with a temperature range of -325°F to 2,150°F / -200°C to 1,175°C. It features an accuracy of ±1.1 °C, a 12 in cable with…

SKU 3G-OTH-179150

Brand
Dayton
Item
Type K Thermocouple, ±1.1°C Accuracy, 12 in FEP Cable, 20 AWG
Category
Thermocouples for Gas Applications
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Dayton
Type
±0.4%/±1.1°C Accuracy, Type K
Accuracy
±1.1 °C
Cable Length
12 in
Cable Material
FEP Insulation
Maximum Wire Gauge
20 AWG

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DAYTON Temperature Probe (SKU 3G-OTH-179150) is a Type K thermocouple for gas applications with a temperature range of -325°F to 2,150°F / -200°C to 1,175°C. It features an accuracy of ±1.1 °C, a 12 in cable with FEP insulation, and a maximum wire gauge of 20 AWG.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the DAYTON temperature probe used for?

The DAYTON Type K thermocouple is designed for gas applications requiring precise temperature measurement from -200°C to 1,175°C. It is commonly used in industrial furnaces, boilers, and process heating systems where accurate monitoring of combustion or exhaust gases is critical.

What are the specifications of the DAYTON temperature probe?

The DAYTON is a Type K thermocouple with an accuracy of ±1.1 °C. It has a 12 in FEP-insulated cable, a maximum wire gauge of 20 AWG, and a temperature range of -200°C to 1,175°C. The manufacturer part number is .

Where to buy the DAYTON temperature probe worldwide?

3G Electric supplies the DAYTON temperature probe worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to install the DAYTON temperature probe?

Install the DAYTON by inserting the probe tip into the gas stream or measurement point, ensuring proper immersion depth. Secure the cable with strain relief and connect the Type K leads to a compatible instrument. Avoid bending the FEP insulation sharply to prevent damage.

Used in

Common applications for Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Products

3G Electric supplies Dayton thermocouples for gas applications. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Type K thermocouple with ±0.4% accuracy and 12-inch FEP-insulated cable, 20 AWG wire. Suitable for gas temperature measurement in industrial furnaces, boilers, and process heating systems
Dayton
Type K thermocouple with ±0.4% accuracy and 12-inch FEP-insulated cable, 20 AWG wire. Suitable for gas temperature measurement in industrial furnaces, boilers, and process heating systems
Type K thermocouple for gas applications with ±1.1°C accuracy. Features a 72-inch fiberglass cable, 20 AWG wire, and weld process mounting connection. Suitable for temperature monitoring in industrial ovens, furnaces, and gas-fired process equipment
Dayton
Type K thermocouple for gas applications with ±1.1°C accuracy. Features a 72-inch fiberglass cable, 20 AWG wire, and weld process mounting connection. Suitable for temperature monitoring in industrial ovens, furnaces, and gas-fired process equipment
Type T thermocouple wire probe for temperature measurement in gas applications such as industrial ovens, furnaces, and HVAC systems. Features ±0.5°C accuracy, 72-inch FEP-insulated cable, and weld process mounting connection. Supports maximum wire gauge of 20 AWG
Dayton
Type T thermocouple wire probe for temperature measurement in gas applications such as industrial ovens, furnaces, and HVAC systems. Features ±0.5°C accuracy, 72-inch FEP-insulated cable, and weld process mounting connection. Supports maximum wire gauge of 20 AWG
Type K thermocouple with a rounded tip for gas applications. Probe length 6 in, cable length 12 in with FEP jacket and stainless steel overbraid. Accuracy ±1.1 °C or ±0.04%, whichever is greater. Maximum wire gauge 28 AWG
Dayton
Type K thermocouple with a rounded tip for gas applications. Probe length 6 in, cable length 12 in with FEP jacket and stainless steel overbraid. Accuracy ±1.1 °C or ±0.04%, whichever is greater. Maximum wire gauge 28 AWG
Type K thermocouple with rounded tip for gas applications. Probe length 6 in, cable length 12 in with FEP jacket and stainless steel overbraid. Accuracy ±1.1 °C or ±0.04%, whichever is greater. Maximum wire gauge 22 AWG. Suitable for temperature measurement in industrial furnaces, boilers, and process heating systems
Dayton
Type K thermocouple with rounded tip for gas applications. Probe length 6 in, cable length 12 in with FEP jacket and stainless steel overbraid. Accuracy ±1.1 °C or ±0.04%, whichever is greater. Maximum wire gauge 22 AWG. Suitable for temperature measurement in industrial furnaces, boilers, and process heating systems
Type K thermocouple with a rounded tip for temperature measurement in gas applications such as industrial furnaces, boilers, and process heating systems. Probe length is 6 inches with a 12-inch cable featuring an FEP jacket and stainless steel overbraid. Accuracy is ±1.1 °C or ±0.04%, whichever is greater, with a maximum wire gauge of 19 AWG
Dayton
Type K thermocouple with a rounded tip for temperature measurement in gas applications such as industrial furnaces, boilers, and process heating systems. Probe length is 6 inches with a 12-inch cable featuring an FEP jacket and stainless steel overbraid. Accuracy is ±1.1 °C or ±0.04%, whichever is greater, with a maximum wire gauge of 19 AWG

More from Dayton

View all Dayton parts
Type K thermocouple probe with a 24-inch probe length, rounded tip, and weld junction. Suitable for temperature measurement in gas-fired ovens, furnaces, and process heating systems. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise
Dayton
Type K thermocouple probe with a 24-inch probe length, rounded tip, and weld junction. Suitable for temperature measurement in gas-fired ovens, furnaces, and process heating systems. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise
Type J thermocouple probe with a rounded tip and 18-inch probe length, 20 AWG wire. Temperature range -210°C to 1,200°C (-346°F to 2,193°F) with accuracy ±1.1% below 293°C and ±0.4% otherwise. Includes hose clamp for installation in gas ducts or pipes for monitoring flue or exhaust gas temperatures
Dayton
Type J thermocouple probe with a rounded tip and 18-inch probe length, 20 AWG wire. Temperature range -210°C to 1,200°C (-346°F to 2,193°F) with accuracy ±1.1% below 293°C and ±0.4% otherwise. Includes hose clamp for installation in gas ducts or pipes for monitoring flue or exhaust gas temperatures
Type J thermocouple probe with a rounded tip and weld junction, 6 in probe length, 20 AWG wire. Temperature range -346°F to 2,193°F (-210°C to 1,200°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Suitable for temperature measurement in gas-fired ovens, furnaces, and process heating systems
Dayton
Type J thermocouple probe with a rounded tip and weld junction, 6 in probe length, 20 AWG wire. Temperature range -346°F to 2,193°F (-210°C to 1,200°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Suitable for temperature measurement in gas-fired ovens, furnaces, and process heating systems
Type K thermocouple with rounded tip for gas applications. Accuracy ±1.1 °C or ±0.04%. Probe length 6 in, cable length 12 in with FEP jacket and stainless steel overbraid. Maximum wire gauge 16 AWG. Suitable for temperature measurement in industrial ovens, furnaces, and exhaust systems
Dayton
Type K thermocouple with rounded tip for gas applications. Accuracy ±1.1 °C or ±0.04%. Probe length 6 in, cable length 12 in with FEP jacket and stainless steel overbraid. Maximum wire gauge 16 AWG. Suitable for temperature measurement in industrial ovens, furnaces, and exhaust systems
Type J thermocouple probe with a 12-inch length and rounded tip, featuring a weld junction. Suitable for gas temperature measurement in industrial furnaces, ovens, and process heating systems. Temperature range: -210°C to 1,200°C. Accuracy: ±1.1% below 293°C, ±0.4% otherwise
Dayton
Type J thermocouple probe with a 12-inch length and rounded tip, featuring a weld junction. Suitable for gas temperature measurement in industrial furnaces, ovens, and process heating systems. Temperature range: -210°C to 1,200°C. Accuracy: ±1.1% below 293°C, ±0.4% otherwise
Type K thermocouple probe with a rounded tip and weld junction, 12 in probe length, 20 AWG wire. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Suitable for temperature measurement in gas-fired equipment such as ovens, furnaces, and exhaust systems
Dayton
Type K thermocouple probe with a rounded tip and weld junction, 12 in probe length, 20 AWG wire. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Suitable for temperature measurement in gas-fired equipment such as ovens, furnaces, and exhaust systems
Type K thermocouple probe with a 6-inch probe length, 20 AWG wire, and a weld junction. Features a rounded tip for gas applications. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C and ±0.4% otherwise. Suitable for temperature measurement in industrial ovens, furnaces, and process heating systems
Dayton
Type K thermocouple probe with a 6-inch probe length, 20 AWG wire, and a weld junction. Features a rounded tip for gas applications. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C and ±0.4% otherwise. Suitable for temperature measurement in industrial ovens, furnaces, and process heating systems
Type K thermocouple probe with a rounded tip and weld junction, 18-inch probe length. Suitable for temperature measurement in gas-fired ovens, furnaces, and exhaust systems. Temperature range -200°C to 1,250°C, accuracy ±1.1% below 293°C and ±0.4% otherwise
Dayton
Type K thermocouple probe with a rounded tip and weld junction, 18-inch probe length. Suitable for temperature measurement in gas-fired ovens, furnaces, and exhaust systems. Temperature range -200°C to 1,250°C, accuracy ±1.1% below 293°C and ±0.4% otherwise