We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Dayton Non-Reversing Definite Purpose Contactor - Non-Reversing Definite Purpose Contactors
DaytonNon-Reversing Definite Purpose Contactors

Dayton Non-Reversing Definite Purpose Contactor

The DAYTON Definite Purpose Magnetic Contactor is a non-reversing, 2-pole contactor with a 2NO main pole contact form, designed for HVACR applications. It features a 24V AC coil voltage, a maximum voltage rating of…

SKU 3G-OTH-42372

Brand
Dayton
Item
Non-Reversing Definite Purpose Contactor
Category
Non-Reversing Definite Purpose Contactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Dayton
Phase
Single
Coil Voltage
24V AC
Mounting Style
Through Panel
Contactor Style
HVACR Definite Purpose Contactor
Main Pole Contact Form
2NO
Maximum Voltage Rating
600V AC
Terminal Connection Type
Box Lugs

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DAYTON Definite Purpose Magnetic Contactor is a non-reversing, 2-pole contactor with a 2NO main pole contact form, designed for HVACR applications. It features a 24V AC coil voltage, a maximum voltage rating of 600V AC, and a 40 A rating. This single-phase contactor mounts through a panel and uses box lug terminals for connections.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the DAYTON Definite Purpose Magnetic Contactor used for?

The DAYTON is a definite purpose magnetic contactor designed for HVACR applications such as controlling compressors, fans, and pumps. Its 2-pole, 2NO configuration and 40 A rating make it suitable for single-phase equipment requiring reliable switching under 600V AC.

What are the specifications of the DAYTON contactor?

The DAYTON is a non-reversing, 2-pole definite purpose contactor with a 24V AC coil voltage, 40 A rating, and maximum voltage rating of 600V AC. It features a 2NO main pole contact form, through-panel mounting, and box lug terminals for secure connections.

Where to buy the DAYTON contactor worldwide?

You can source the DAYTON contactor from 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations, ensuring you receive the correct HVACR component for your application.

How to install the DAYTON definite purpose contactor?

Mount the DAYTON through a panel using the provided hardware. Connect power and load wires to the box lug terminals, ensuring torque meets manufacturer recommendations. Apply 24V AC to the coil for switching. Always follow local electrical codes and de-energize the circuit before installation.

Used in

Common applications for Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Products

3G Electric supplies Dayton non-reversing definite purpose contactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
DAYTON Definite Purpose Magnetic Contactor: 2 Poles, 24V AC, 20 A, Non-Reversing
Dayton
DAYTON Definite Purpose Magnetic Contactor: 2 Poles, 24V AC, 20 A, Non-Reversing
DAYTON Definite Purpose Magnetic Contactor: 2 Poles, 208-240V AC, 40 A, Non-Reversing
Dayton
DAYTON Definite Purpose Magnetic Contactor: 2 Poles, 208-240V AC, 40 A, Non-Reversing
DAYTON Definite Purpose Magnetic Contactor: 2 Poles, 208-240V AC, 20 A, Non-Reversing
Dayton
DAYTON Definite Purpose Magnetic Contactor: 2 Poles, 208-240V AC, 20 A, Non-Reversing
This non-reversing definite purpose contactor is designed for HVACR applications, switching single-phase loads such as compressors, fan motors, and condenser units. It features a 24V AC coil, 2 normally open main poles, and a maximum voltage rating of 600V AC. The contactor uses box lug terminals and is mounted through the panel
Dayton
This non-reversing definite purpose contactor is designed for HVACR applications, switching single-phase loads such as compressors, fan motors, and condenser units. It features a 24V AC coil, 2 normally open main poles, and a maximum voltage rating of 600V AC. The contactor uses box lug terminals and is mounted through the panel
DAYTON Definite Purpose Magnetic Contactor: 2 Poles, 24V AC, 20 A, Non-Reversing
Dayton
DAYTON Definite Purpose Magnetic Contactor: 2 Poles, 24V AC, 20 A, Non-Reversing
DAYTON Definite Purpose Magnetic Contactor: 2 Poles, 24V AC, 32 A, Non-Reversing
Dayton
DAYTON Definite Purpose Magnetic Contactor: 2 Poles, 24V AC, 32 A, Non-Reversing

More from Dayton

View all Dayton parts
Three-pole, non-reversing definite purpose contactor with a 24V AC coil and 40 A rating. Features 3NO main pole contact form, 600V AC maximum voltage rating, and box lug terminal connections. Designed for through-panel mounting in HVACR applications such as switching three-phase motors and compressors
Dayton
Three-pole, non-reversing definite purpose contactor with a 24V AC coil and 40 A rating. Features 3NO main pole contact form, 600V AC maximum voltage rating, and box lug terminal connections. Designed for through-panel mounting in HVACR applications such as switching three-phase motors and compressors
This non-reversing definite purpose contactor is designed for HVACR applications such as controlling compressors, fans, and pumps in single-phase systems. It features a 2-pole normally open contact form, 120V AC coil voltage, and a maximum rating of 600V AC. The contactor mounts through a panel and uses screw terminals for wiring
Dayton
This non-reversing definite purpose contactor is designed for HVACR applications such as controlling compressors, fans, and pumps in single-phase systems. It features a 2-pole normally open contact form, 120V AC coil voltage, and a maximum rating of 600V AC. The contactor mounts through a panel and uses screw terminals for wiring
This non-reversing definite purpose contactor is rated 25 A with a 2NO main pole contact form. It operates on single-phase power up to 600V AC and features a 120V AC coil. Designed for through-panel mounting with screw terminals, it is suitable for switching loads in HVACR equipment such as air conditioners, heat pumps, and refrigeration units
Dayton
This non-reversing definite purpose contactor is rated 25 A with a 2NO main pole contact form. It operates on single-phase power up to 600V AC and features a 120V AC coil. Designed for through-panel mounting with screw terminals, it is suitable for switching loads in HVACR equipment such as air conditioners, heat pumps, and refrigeration units
This single-phase definite purpose contactor is designed for HVACR applications such as controlling compressors, fans, and pumps. It features a 2NO main pole contact form, 24V AC coil, and screw terminals. Rated 25 A at 600V AC maximum, it mounts through the panel
Dayton
This single-phase definite purpose contactor is designed for HVACR applications such as controlling compressors, fans, and pumps. It features a 2NO main pole contact form, 24V AC coil, and screw terminals. Rated 25 A at 600V AC maximum, it mounts through the panel
This non-reversing definite purpose contactor is designed for HVACR applications such as controlling compressors, fans, and pumps. It features a 2-pole normally open (2NO) main pole contact form, a 120V AC coil, and a maximum voltage rating of 600V AC. The unit is single-phase, rated 30 A, and mounts through a panel with screw terminals for connection
Dayton
This non-reversing definite purpose contactor is designed for HVACR applications such as controlling compressors, fans, and pumps. It features a 2-pole normally open (2NO) main pole contact form, a 120V AC coil, and a maximum voltage rating of 600V AC. The unit is single-phase, rated 30 A, and mounts through a panel with screw terminals for connection
Three-pole non-reversing definite purpose contactor with 24V AC coil and 25 A rating. Features 3NO main pole contacts, box lug terminals, and through-panel mounting. Suitable for switching three-phase loads in HVACR equipment such as compressors, condenser fans, and pumps
Dayton
Three-pole non-reversing definite purpose contactor with 24V AC coil and 25 A rating. Features 3NO main pole contacts, box lug terminals, and through-panel mounting. Suitable for switching three-phase loads in HVACR equipment such as compressors, condenser fans, and pumps
Three-pole, non-reversing definite purpose contactor with 3NO main pole contact form. Rated 75 A, 600V AC maximum, with 120V AC coil. Features through-panel mounting and box lug terminals. Used for switching HVACR equipment such as compressors and fans in three-phase applications
Dayton
Three-pole, non-reversing definite purpose contactor with 3NO main pole contact form. Rated 75 A, 600V AC maximum, with 120V AC coil. Features through-panel mounting and box lug terminals. Used for switching HVACR equipment such as compressors and fans in three-phase applications
Three-pole, non-reversing definite purpose contactor with 3NO main pole contact form. Rated 40 A, 600V AC maximum voltage, with 120V AC coil. Box lug terminals for wiring; through-panel mounting. Suitable for switching loads in HVACR equipment such as compressors, fans, and pumps
Dayton
Three-pole, non-reversing definite purpose contactor with 3NO main pole contact form. Rated 40 A, 600V AC maximum voltage, with 120V AC coil. Box lug terminals for wiring; through-panel mounting. Suitable for switching loads in HVACR equipment such as compressors, fans, and pumps