We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Dayton Ring Thermocouple: -325°F to 500°F /-200°C to 260°C, ±0.4%/±0.5°C Accuracy - Thermocouples for Surface Applications
DaytonThermocouples for Surface Applications

Dayton Ring Thermocouple: -325°F to 500°F /-200°C to 260°C, ±0.4%/±0.5°C Accuracy

The DAYTON Ring Thermocouple (SKU 826Y35) is a Type T thermocouple for surface applications, with a temperature range of -325°F to 500°F (-200°C to 260°C) and an accuracy of ±0.5 °C. It features a 72-inch cable with…

SKU 3G-OTH-182378

Brand
Dayton
Item
Ring Thermocouple: -325°F to 500°F /-200°C to 260°C, ±0.4%/±0.5°C Accuracy
Category
Thermocouples for Surface Applications
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

Dayton
Manufacturer Part Number
826Y35
Type
±0.4%/±0.5°C Accuracy, Type T, Bolt
Accuracy
±0.5 °C
Cable Length
72 in
Cable Material
FEP Insulation
Maximum Wire Gauge
20 AWG
Process Mounting Connection
Bolt
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DAYTON Ring Thermocouple (SKU 826Y35) is a Type T thermocouple for surface applications, with a temperature range of -325°F to 500°F (-200°C to 260°C) and an accuracy of ±0.5 °C. It features a 72-inch cable with FEP insulation, a bolt-style process mounting connection, and a maximum wire gauge of 20 AWG.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the DAYTON Ring Thermocouple used for?

The DAYTON Ring Thermocouple is used for surface temperature measurement in industrial applications. It is ideal for monitoring pipes, tanks, and machinery surfaces where a bolt-mounted sensor is required. Its Type T thermocouple provides reliable readings from -325°F to 500°F (-200°C to 260°C).

What are the specifications of the DAYTON Ring Thermocouple 826Y35?

The DAYTON Ring Thermocouple 826Y35 is a Type T thermocouple with ±0.5 °C accuracy. It has a 72-inch FEP-insulated cable, a bolt-style process mounting connection, and a maximum wire gauge of 20 AWG. Its temperature range is -325°F to 500°F (-200°C to 260°C).

Where to buy the DAYTON Ring Thermocouple worldwide?

You can source the DAYTON Ring Thermocouple 826Y35 through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time.

How to install a bolt-mounted ring thermocouple?

To install a bolt-mounted ring thermocouple like the DAYTON 826Y35, clean the surface, apply thermal paste for better contact, and tighten the bolt securely. Ensure the cable is routed away from heat sources and sharp edges. Follow standard thermocouple wiring practices for Type T connections.

Used in

Common applications for Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Products

3G Electric supplies Dayton thermocouples for surface applications. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
DAYTON Temperature Probe: -325°F to 2,150°F /-200°C to 1,175°C, ±0.4%/±1.1°C Accuracy, Type K (MPN 826Y33). Key specifications — Brand: DAYTON; Cable Material: FEP Insulation; Cable Length: 12 in; Accuracy: ±1.1 °C; Maximum Wire Gauge: 20 AWG.
Dayton
DAYTON Temperature Probe: -325°F to 2,150°F /-200°C to 1,175°C, ±0.4%/±1.1°C Accuracy, Type K (MPN 826Y33). Key specifications — Brand: DAYTON; Cable Material: FEP Insulation; Cable Length: 12 in; Accuracy: ±1.1 °C; Maximum Wire Gauge: 20 AWG.
DAYTON Thermocouple Wire Probe: -325°F to 500°F /-200°C to 260°C, ±0.4%/±0.5°C Accuracy, Type T (MPN 826Y37). Key specifications — Brand: DAYTON; Cable Material: FEP Insulation; Cable Length: 72 in; Accuracy: ±0.5 °C; Process Mounting Connection: Weld; Maximum Wire Gauge: 20 AWG.
Dayton
DAYTON Thermocouple Wire Probe: -325°F to 500°F /-200°C to 260°C, ±0.4%/±0.5°C Accuracy, Type T (MPN 826Y37). Key specifications — Brand: DAYTON; Cable Material: FEP Insulation; Cable Length: 72 in; Accuracy: ±0.5 °C; Process Mounting Connection: Weld; Maximum Wire Gauge: 20 AWG.
DAYTON Temperature Probe: -325°F to 2,150°F /-200°C to 1,175°C, ±0.4%/±1.1°C Accuracy, Type K (MPN 826Y34). Key specifications — Brand: DAYTON; Cable Material: FEP Insulation; Cable Length: 12 in; Accuracy: ±0.4 %; Maximum Wire Gauge: 20 AWG.
Dayton
DAYTON Temperature Probe: -325°F to 2,150°F /-200°C to 1,175°C, ±0.4%/±1.1°C Accuracy, Type K (MPN 826Y34). Key specifications — Brand: DAYTON; Cable Material: FEP Insulation; Cable Length: 12 in; Accuracy: ±0.4 %; Maximum Wire Gauge: 20 AWG.
DAYTON Thermocouple Wire Probe: -325°F to 1,600°F /-200°C to 871°C, ±0.4%/±1.1°C Accuracy, Type K (MPN 826Y38). Key specifications — Brand: DAYTON; Cable Material: Fiberglass; Cable Length: 72 in; Accuracy: ±1.1 °C; Process Mounting Connection: Weld; Maximum Wire Gauge: 20 AWG.
Dayton
DAYTON Thermocouple Wire Probe: -325°F to 1,600°F /-200°C to 871°C, ±0.4%/±1.1°C Accuracy, Type K (MPN 826Y38). Key specifications — Brand: DAYTON; Cable Material: Fiberglass; Cable Length: 72 in; Accuracy: ±1.1 °C; Process Mounting Connection: Weld; Maximum Wire Gauge: 20 AWG.
DAYTON Thermocouple Probe: -325°F to 2,280°F /-200°C to 1,250°C, Type K, Rounded Tip, 6 in Probe Lg (MPN 798GE5). Key specifications — Brand: DAYTON; Cable Material: FEP Jacket with Stainless Steel Overbraid; Cable Length: 12 in; Accuracy: ±1.1 °C or ±0.04 %, Whichever is Greater; Maximum Wire Gauge: 22 AWG.
Dayton
DAYTON Thermocouple Probe: -325°F to 2,280°F /-200°C to 1,250°C, Type K, Rounded Tip, 6 in Probe Lg (MPN 798GE5). Key specifications — Brand: DAYTON; Cable Material: FEP Jacket with Stainless Steel Overbraid; Cable Length: 12 in; Accuracy: ±1.1 °C or ±0.04 %, Whichever is Greater; Maximum Wire Gauge: 22 AWG.
DAYTON Thermocouple Probe: -325°F to 2,280°F /-200°C to 1,250°C, Type K, Rounded Tip, 6 in Probe Lg (MPN 798GE6). Key specifications — Brand: DAYTON; Cable Material: FEP Jacket with Stainless Steel Overbraid; Cable Length: 12 in; Accuracy: ±1.1 °C or ±0.04 %, Whichever is Greater; Maximum Wire Gauge: 19 AWG.
Dayton
DAYTON Thermocouple Probe: -325°F to 2,280°F /-200°C to 1,250°C, Type K, Rounded Tip, 6 in Probe Lg (MPN 798GE6). Key specifications — Brand: DAYTON; Cable Material: FEP Jacket with Stainless Steel Overbraid; Cable Length: 12 in; Accuracy: ±1.1 °C or ±0.04 %, Whichever is Greater; Maximum Wire Gauge: 19 AWG.

More from Dayton

View all Dayton parts
DAYTON Thermocouple Probe: -325°F to 2,280°F /-200°C to 1,250°C, Type K, Rounded Tip, 6 in Probe Lg (MPN 798GE8). Key specifications — Brand: DAYTON; Cable Material: FEP Jacket with Stainless Steel Overbraid; Cable Length: 12 in; Accuracy: ±1.1 °C or ±0.04 %, Whichever is Greater; Maximum Wire Gauge: 28 AWG.
Dayton
DAYTON Thermocouple Probe: -325°F to 2,280°F /-200°C to 1,250°C, Type K, Rounded Tip, 6 in Probe Lg (MPN 798GE8). Key specifications — Brand: DAYTON; Cable Material: FEP Jacket with Stainless Steel Overbraid; Cable Length: 12 in; Accuracy: ±1.1 °C or ±0.04 %, Whichever is Greater; Maximum Wire Gauge: 28 AWG.
DAYTON Ring Thermocouple: -325°F to 500°F /-200°C to 260°C, ±0.4%/±1.1°C Accuracy, Type K, Bolt (MPN 826Y36). Key specifications — Brand: DAYTON; Cable Material: FEP Insulation; Cable Length: 72 in; Accuracy: ±0.4 %; Process Mounting Connection: Bolt; Maximum Wire Gauge: 20 AWG.
Dayton
DAYTON Ring Thermocouple: -325°F to 500°F /-200°C to 260°C, ±0.4%/±1.1°C Accuracy, Type K, Bolt (MPN 826Y36). Key specifications — Brand: DAYTON; Cable Material: FEP Insulation; Cable Length: 72 in; Accuracy: ±0.4 %; Process Mounting Connection: Bolt; Maximum Wire Gauge: 20 AWG.