We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

CHEMETRICS Peracetic Acid Test Kit, 0 to 5 ppm, 30 Tests, I-2020 - Water Quality Test Kits
CHEMETRICSWater Quality Test Kits

CHEMETRICS Peracetic Acid Test Kit, 0 to 5 ppm, 30 Tests, I-2020

The CHEMETRICS Water Quality Test Kit (MPN I-2020) is a peracetic acid test kit with a range of 0 to 5 ppm and 30 tests per kit. It includes a Light Shield and offers sensitivity of ≤0.10 ppm at 0 ppm, ±0.12 ppm at…

SKU 3G-OTH-376570

Also listed as: I2020 · I 2020

Brand
CHEMETRICS
Item
Peracetic Acid Test Kit, 0 to 5 ppm, 30 Tests, I-2020
Category
Water Quality Test Kits
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

CHEMETRICS
Manufacturer Part Number
I-2020
Range
0 to 5 ppm
Includes
Light Shield
Sensitivity
≤0.10 ppm at 0 ppm±0.12 ppm at 0.40 ppm±0.25 ppm at 1.25 ppm±0.38 ppm at 3.75 ppm
Test Parameters
Peracetic Acid

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CHEMETRICS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The CHEMETRICS Water Quality Test Kit (MPN I-2020) is a peracetic acid test kit with a range of 0 to 5 ppm and 30 tests per kit. It includes a Light Shield and offers sensitivity of ≤0.10 ppm at 0 ppm, ±0.12 ppm at 0.40 ppm, ±0.25 ppm at 1.25 ppm, and ±0.38 ppm at 3.75 ppm.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the CHEMETRICS Water Quality Test Kit I-2020 used for?

The CHEMETRICS Water Quality Test Kit I-2020 is used to measure peracetic acid concentration in water, typically in industrial disinfection and sanitation processes. It provides 30 tests per kit with a range of 0 to 5 ppm, making it suitable for monitoring water treatment in food processing, healthcare, and agriculture.

What are the specifications of the CHEMETRICS Water Quality Test Kit I-2020?

The CHEMETRICS Water Quality Test Kit I-2020 has a range of 0 to 5 ppm for peracetic acid, with sensitivity of ≤0.10 ppm at 0 ppm, ±0.12 ppm at 0.40 ppm, ±0.25 ppm at 1.25 ppm, and ±0.38 ppm at 3.75 ppm. It includes a Light Shield and comes with 30 tests per kit.

Where to buy the CHEMETRICS Water Quality Test Kit I-2020 worldwide?

You can source the CHEMETRICS Water Quality Test Kit I-2020 through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations, ensuring the kit reaches your facility reliably.

How to use the CHEMETRICS Water Quality Test Kit I-2020?

To use the CHEMETRICS Water Quality Test Kit I-2020, fill the sample cup to the line, add the reagent, and insert the Light Shield. Compare the color change to the provided chart to read peracetic acid concentration in ppm. Follow the manufacturer's instructions for accurate results.

Used in

Common applications for CHEMETRICS
Boiler water treatment — CHEMETRICS Chemical Oxygen Demand kit (K-7355) for monitoring organic contaminants in feedwater.
Wastewater effluent monitoring — CHEMETRICS Total Chlorine kit (K-2513) for compliance testing of disinfection residuals.
Cooling tower management — CHEMETRICS Ozone kit (I-2019) for tracking ozone levels in recirculating water systems.
Industrial process water — CHEMETRICS Hydrogen Peroxide kit (K-5520B) for verifying peroxide concentrations in bleaching or cleaning operations.
Groundwater analysis — CHEMETRICS Iron kit (K-6002) for detecting iron contamination in well water or remediation sites.
Drinking water disinfection — CHEMETRICS Monochloramine kit (K-6802) for monitoring chloramine levels in municipal distribution systems.

CHEMETRICS Products

3G Electric supplies CHEMETRICS water quality test kits. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Related products

More from CHEMETRICS

View all CHEMETRICS parts
This test kit measures chemical oxygen demand (COD) in water samples over a range of 0 to 15,000 ppm. It includes 25 vials and performs 24 tests. Sensitivity is specified as 230 mg/L for spectrophotometer and ±200 mg/L for LED photometer. Typical applications include wastewater treatment, environmental monitoring, and industrial process control to assess organic pollutant levels
CHEMETRICS
This test kit measures chemical oxygen demand (COD) in water samples over a range of 0 to 15,000 ppm. It includes 25 vials and performs 24 tests. Sensitivity is specified as 230 mg/L for spectrophotometer and ±200 mg/L for LED photometer. Typical applications include wastewater treatment, environmental monitoring, and industrial process control to assess organic pollutant levels
This test kit measures ozone concentration in water over a range of 0 to 0.75 ppm with a sensitivity of 0.16 mg/L (0.15-0.17 mg/L with I-2022 SAM). It includes a SAM Photometer and provides 30 tests per kit. Typical applications include monitoring ozone levels in water treatment, aquaculture, and industrial process water
CHEMETRICS
This test kit measures ozone concentration in water over a range of 0 to 0.75 ppm with a sensitivity of 0.16 mg/L (0.15-0.17 mg/L with I-2022 SAM). It includes a SAM Photometer and provides 30 tests per kit. Typical applications include monitoring ozone levels in water treatment, aquaculture, and industrial process water
This test kit measures hydrogen peroxide concentration in water over a range of 25 to 250 ppm with a sensitivity of 25 ppm. It includes a 25 mL sample cup and provides 30 tests per package. Used for monitoring peroxide levels in industrial water treatment and disinfection processes
CHEMETRICS
This test kit measures hydrogen peroxide concentration in water over a range of 25 to 250 ppm with a sensitivity of 25 ppm. It includes a 25 mL sample cup and provides 30 tests per package. Used for monitoring peroxide levels in industrial water treatment and disinfection processes
This test kit measures chloride concentration in water over a range of 1,000 to 10,000 ppm with a sensitivity of 1,000 ppm. It includes Activator Solution and provides 30 tests per kit. Used for water quality monitoring in industrial and environmental applications
CHEMETRICS
This test kit measures chloride concentration in water over a range of 1,000 to 10,000 ppm with a sensitivity of 1,000 ppm. It includes Activator Solution and provides 30 tests per kit. Used for water quality monitoring in industrial and environmental applications
This test kit measures sulfide concentration in water over a range of 0 to 6 ppm. It includes a 25 mL sample cup and provides 30 tests. Sensitivity is ≤ 0.30 ppm at 0 ppm, ± 0.18 ppm at 0.60 ppm, ± 0.45 ppm at 1.50 ppm, and ± 1.35 ppm at 4.50 ppm. Typical applications include monitoring sulfide levels in industrial wastewater, environmental water samples, and water treatment processes
CHEMETRICS
This test kit measures sulfide concentration in water over a range of 0 to 6 ppm. It includes a 25 mL sample cup and provides 30 tests. Sensitivity is ≤ 0.30 ppm at 0 ppm, ± 0.18 ppm at 0.60 ppm, ± 0.45 ppm at 1.50 ppm, and ± 1.35 ppm at 4.50 ppm. Typical applications include monitoring sulfide levels in industrial wastewater, environmental water samples, and water treatment processes
This test kit measures iron levels in water across two ranges: 0 to 1 ppm and 1 to 10 ppm, with a sensitivity of 0.05 ppm. It includes Activator Solution and provides 30 tests. Typical applications include monitoring iron content in industrial water systems and environmental water samples
CHEMETRICS
This test kit measures iron levels in water across two ranges: 0 to 1 ppm and 1 to 10 ppm, with a sensitivity of 0.05 ppm. It includes Activator Solution and provides 30 tests. Typical applications include monitoring iron content in industrial water systems and environmental water samples
This test kit measures iron concentration in water over a range of 0 to 6 ppm. It includes an Activator Solution and provides 30 tests per kit. Sensitivity is ≤ 0.08 ppm at 0 ppm, ± 0.09 ppm at 0.30 ppm, ± 0.30 ppm at 1.50 ppm, and ± 0.45 ppm at 4.50 ppm. Commonly used for monitoring iron levels in water treatment and environmental testing
CHEMETRICS
This test kit measures iron concentration in water over a range of 0 to 6 ppm. It includes an Activator Solution and provides 30 tests per kit. Sensitivity is ≤ 0.08 ppm at 0 ppm, ± 0.09 ppm at 0.30 ppm, ± 0.30 ppm at 1.50 ppm, and ± 0.45 ppm at 4.50 ppm. Commonly used for monitoring iron levels in water treatment and environmental testing
This test kit measures chloride concentration in water over a range of 0 to 40 ppm. It includes an Ampoule Blank and provides 29 tests per kit. Sensitivity is ≤ 1.3 ppm at 0 ppm, ± 1.5 ppm at 5.0 ppm, ± 2.5 ppm at 10.0 ppm, and ± 4.5 ppm at 30.0 ppm. Typical applications include monitoring chloride levels in industrial water treatment and environmental water samples
CHEMETRICS
This test kit measures chloride concentration in water over a range of 0 to 40 ppm. It includes an Ampoule Blank and provides 29 tests per kit. Sensitivity is ≤ 1.3 ppm at 0 ppm, ± 1.5 ppm at 5.0 ppm, ± 2.5 ppm at 10.0 ppm, and ± 4.5 ppm at 30.0 ppm. Typical applications include monitoring chloride levels in industrial water treatment and environmental water samples