We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

CHEMETRICS Water Quality Test Kit: Ammonia, 0 to 10 ppm/0 to 150 ppm - Water Quality Test Kits
CHEMETRICSWater Quality Test Kits

CHEMETRICS Water Quality Test Kit: Ammonia, 0 to 10 ppm/0 to 150 ppm

The CHEMETRICS Water Quality Test Kit (MPN K-1513) is a 30-test kit for measuring ammonia in water, with a range of 0 to 150 ppm and sensitivity specifications provided for both the 0–10.00 ppm and 0–150 ppm ranges…

SKU 3G-OTH-376560

Brand
CHEMETRICS
Item
Water Quality Test Kit: Ammonia, 0 to 10 ppm/0 to 150 ppm
Category
Water Quality Test Kits
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

CHEMETRICS
Manufacturer Part Number
K-1513
Range
0 to 150 ppm
Includes
25 mL Sample Cup
Sensitivity
0 – 10.00 ppm range≤ 0.15 ppm at 0 ppm± 0.15 ppm at 0.50 ppm± 0.50 ppm at 2.50 ppm± 0.75 ppm at 7.50 ppm0 – 150 ppm range≤ 2 ppm at 0 ppm± 2 ppm at 8 ppm± 8 ppm at 38 ppm± 11 ppm at 112 ppm
Test Parameters
Ammonia
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CHEMETRICS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The CHEMETRICS Water Quality Test Kit (MPN K-1513) is a 30-test kit for measuring ammonia in water, with a range of 0 to 150 ppm and sensitivity specifications provided for both the 0–10.00 ppm and 0–150 ppm ranges. It includes a 25 mL sample cup.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

What is the CHEMETRICS Water Quality Test Kit K-1513 used for?

The CHEMETRICS Water Quality Test Kit K-1513 is used to measure ammonia levels in water. It is suitable for environmental monitoring, wastewater treatment, and industrial process water testing, providing 30 tests per kit with a range of 0 to 150 ppm.

What are the specifications of the CHEMETRICS K-1513 ammonia test kit?

The CHEMETRICS K-1513 test kit has a range of 0 to 150 ppm for ammonia. Sensitivity is specified for two ranges: 0–10.00 ppm (e.g., ±0.15 ppm at 0.50 ppm) and 0–150 ppm (e.g., ±2 ppm at 8 ppm). It includes a 25 mL sample cup and performs 30 tests.

Where to buy CHEMETRICS K-1513 test kits worldwide?

You can source the CHEMETRICS K-1513 ammonia test kit worldwide through 3G Electric. As a global industrial equipment distributor, 3G Electric handles full logistics, customs clearance, and delivery to your location, ensuring reliable supply for your water quality testing needs.

How to use the CHEMETRICS K-1513 ammonia test kit?

To use the CHEMETRICS K-1513 kit, fill the 25 mL sample cup with water, add the reagent from the provided ampoules, and compare the color change to the included comparator. Follow the manufacturer's instructions for accurate results. For maintenance, store the kit in a cool, dry place and check expiration dates.

Used in

Common applications for CHEMETRICS
Boiler water treatment — CHEMETRICS Chemical Oxygen Demand kit (K-7355) for monitoring organic contaminants in feedwater.
Wastewater effluent monitoring — CHEMETRICS Total Chlorine kit (K-2513) for compliance testing of disinfection residuals.
Cooling tower management — CHEMETRICS Ozone kit (I-2019) for tracking ozone levels in recirculating water systems.
Industrial process water — CHEMETRICS Hydrogen Peroxide kit (K-5520B) for verifying peroxide concentrations in bleaching or cleaning operations.
Groundwater analysis — CHEMETRICS Iron kit (K-6002) for detecting iron contamination in well water or remediation sites.
Drinking water disinfection — CHEMETRICS Monochloramine kit (K-6802) for monitoring chloramine levels in municipal distribution systems.

CHEMETRICS Products

3G Electric supplies CHEMETRICS water quality test kits. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
CHEMETRICS Water Quality Test Kit: Ammonia, 0 to 1 ppm/1 to 10 ppm, 0.05 ppm, 30 Tests (MPN K-1510). Key specifications — Includes: Stabilizer Solution; Range: 0 to 1 ppm; Sensitivity: 0.05 ppm; Test Parameters: Ammonia.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Ammonia, 0 to 1 ppm/1 to 10 ppm, 0.05 ppm, 30 Tests (MPN K-1510). Key specifications — Includes: Stabilizer Solution; Range: 0 to 1 ppm; Sensitivity: 0.05 ppm; Test Parameters: Ammonia.
CHEMETRICS Water Quality Test Kit: Ammonia, 0 to 4 ppm/0 to 80 ppm, 0.125 ppm, 30 Tests (MPN K-1420). Key specifications — Includes: CHEMets® Refill; Range: 0 to 80 ppm; Sensitivity: 0.125 ppm; Test Parameters: Ammonia.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Ammonia, 0 to 4 ppm/0 to 80 ppm, 0.125 ppm, 30 Tests (MPN K-1420). Key specifications — Includes: CHEMets® Refill; Range: 0 to 80 ppm; Sensitivity: 0.125 ppm; Test Parameters: Ammonia.
CHEMETRICS Water Quality Test Kit: Monochloramine, 30 Tests (MPN K-6803). Key specifications — Includes: 25 mL Sample Cup; Range: (V-2000) 0 to 15.0 ppm (V-3000& Spec); Sensitivity: V-2000≤0.25 ppm at 0 ppm±0.3 ppm at 1.0 ppm±0.8 ppm at 3.8 ppm±1.1 ppm at 11.3 ppmV-3000 & Spec≤0.125 ppm at 0 ppm±0.15 ppm at 0.50 ppm±0.40 ppm at 2.00 ppm±0.60 ppm at 6.00 ppm; Test Parameters: Monochloramine.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Monochloramine, 30 Tests (MPN K-6803). Key specifications — Includes: 25 mL Sample Cup; Range: (V-2000) 0 to 15.0 ppm (V-3000& Spec); Sensitivity: V-2000≤0.25 ppm at 0 ppm±0.3 ppm at 1.0 ppm±0.8 ppm at 3.8 ppm±1.1 ppm at 11.3 ppmV-3000 & Spec≤0.125 ppm at 0 ppm±0.15 ppm at 0.50 ppm±0.40 ppm at 2.00 ppm±0.60 ppm at 6.00 ppm; Test Parameters: Monochloramine.
CHEMETRICS Water Quality Test Kit: Chloride, 0 to 40 ppm, 29 Tests (MPN K-2103). Key specifications — Includes: Ampoule Blank; Range: 0 to 40 ppm; Sensitivity: ≤ 1.3 ppm at 0 ppm± 1.5 ppm at 5.0 ppm± 2.5 ppm at 10.0 ppm± 4.5 ppm at 30.0 ppm; Test Parameters: Chloride.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Chloride, 0 to 40 ppm, 29 Tests (MPN K-2103). Key specifications — Includes: Ampoule Blank; Range: 0 to 40 ppm; Sensitivity: ≤ 1.3 ppm at 0 ppm± 1.5 ppm at 5.0 ppm± 2.5 ppm at 10.0 ppm± 4.5 ppm at 30.0 ppm; Test Parameters: Chloride.
CHEMETRICS Water Quality Test Kit: Dissolved Oxygen, 0 to 15 ppm, 30 Tests (MPN K-7513). Key specifications — Includes: (30) Ampoules; Range: 0 to 15 ppm; Sensitivity: ± 0.6 ppm at 2.0 ppm± 0.8 ppm at 4.0 ppm± 1.7 ppm at 11.0 ppm; Test Parameters: Dissolved Oxygen.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Dissolved Oxygen, 0 to 15 ppm, 30 Tests (MPN K-7513). Key specifications — Includes: (30) Ampoules; Range: 0 to 15 ppm; Sensitivity: ± 0.6 ppm at 2.0 ppm± 0.8 ppm at 4.0 ppm± 1.7 ppm at 11.0 ppm; Test Parameters: Dissolved Oxygen.
CHEMETRICS Water Quality Test Kit: Chloride, 20 to 200 ppm, 20 ppm, 30 Tests (MPN K-2020). Key specifications — Includes: (30) Ampoules with Valve Assemblies; Range: 20 to 200 ppm; Sensitivity: 20 ppm; Test Parameters: Chloride.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Chloride, 20 to 200 ppm, 20 ppm, 30 Tests (MPN K-2020). Key specifications — Includes: (30) Ampoules with Valve Assemblies; Range: 20 to 200 ppm; Sensitivity: 20 ppm; Test Parameters: Chloride.

More from CHEMETRICS

View all CHEMETRICS parts
CHEMETRICS Water Quality Test Kit: Sulfide, 125 to 1,250 ppm, 125 ppm, 30 Tests (MPN K-9520B). Key specifications — Includes: HR CHEMets® Refill Ampoules; Range: 125 to 1,250 ppm; Sensitivity: 125 ppm; Test Parameters: Sulfide.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Sulfide, 125 to 1,250 ppm, 125 ppm, 30 Tests (MPN K-9520B). Key specifications — Includes: HR CHEMets® Refill Ampoules; Range: 125 to 1,250 ppm; Sensitivity: 125 ppm; Test Parameters: Sulfide.
CHEMETRICS Water Quality Test Kit: Hydrogen Peroxide, 125 to 1,250 ppm, 125 ppm, 30 Tests (MPN K-5520B). Key specifications — Includes: 25 mL Sample Cup; Range: 125 to 1,250 ppm; Sensitivity: 125 ppm; Test Parameters: Hydrogen Peroxide.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Hydrogen Peroxide, 125 to 1,250 ppm, 125 ppm, 30 Tests (MPN K-5520B). Key specifications — Includes: 25 mL Sample Cup; Range: 125 to 1,250 ppm; Sensitivity: 125 ppm; Test Parameters: Hydrogen Peroxide.
CHEMETRICS Water Quality Test Kit: Ozone, 0 to 0.05 ppm, 30 Tests, Pre-Measured Vacu-Vials® (MPN K-7423). Key specifications — Includes: Pre-Measured Vacu-Vials®; Range: 0 to 0.05 ppm; Sensitivity: ≤0.05 ppm at 0 ppm±0.06 ppm at 0.20 ppm±0.25 ppm at 1.25 ppm±0.38 ppm at 3.75 ppm; Test Parameters: Ozone.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Ozone, 0 to 0.05 ppm, 30 Tests, Pre-Measured Vacu-Vials® (MPN K-7423). Key specifications — Includes: Pre-Measured Vacu-Vials®; Range: 0 to 0.05 ppm; Sensitivity: ≤0.05 ppm at 0 ppm±0.06 ppm at 0.20 ppm±0.25 ppm at 1.25 ppm±0.38 ppm at 3.75 ppm; Test Parameters: Ozone.
CHEMETRICS Water Quality Test Kit: Ozone, 0 to 5 ppm, 30 Tests (MPN I-2019). Key specifications — Includes: Screwdriver; Range: 0 to 5 ppm; Sensitivity: ≤0.05 ppm at 0 ppm±0.06 ppm at 0.20 ppm±0.25 ppm at 1.25 ppm±0.38 ppm at 3.75 ppm; Test Parameters: Ozone.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Ozone, 0 to 5 ppm, 30 Tests (MPN I-2019). Key specifications — Includes: Screwdriver; Range: 0 to 5 ppm; Sensitivity: ≤0.05 ppm at 0 ppm±0.06 ppm at 0.20 ppm±0.25 ppm at 1.25 ppm±0.38 ppm at 3.75 ppm; Test Parameters: Ozone.
CHEMETRICS Water Quality Test Kit: Iron, 0 to 100 mg/L/100 to 1,000 mg/L, 5 mg/L, 30 Tests (MPN K-6002). Key specifications — Includes: Activator Solution; Range: 0 to 100 mg/L; Sensitivity: 5 mg/L; Test Parameters: Iron.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Iron, 0 to 100 mg/L/100 to 1,000 mg/L, 5 mg/L, 30 Tests (MPN K-6002). Key specifications — Includes: Activator Solution; Range: 0 to 100 mg/L; Sensitivity: 5 mg/L; Test Parameters: Iron.
CHEMETRICS Water Quality Test Kit: Monochloramine, 0 to 20 ppm, 0.625 ppm, 30 Tests (MPN K-6802). Key specifications — Includes: Stabilizer Solution; Range: 0 to 20 ppm; Sensitivity: 0.625 ppm; Test Parameters: Monochloramine.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Monochloramine, 0 to 20 ppm, 0.625 ppm, 30 Tests (MPN K-6802). Key specifications — Includes: Stabilizer Solution; Range: 0 to 20 ppm; Sensitivity: 0.625 ppm; Test Parameters: Monochloramine.
CHEMETRICS Water Quality Test Kit: Total Chlorine, 0 to 5 ppm, 0.12 ppm/0.25 ppm/0.2 ppm/0.38 ppm (MPN K-2513). Key specifications — Includes: 25 mL Sample Cup; Range: 0 to 5 ppm; Sensitivity: 0.25 ppm; Test Parameters: Total Chlorine.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Total Chlorine, 0 to 5 ppm, 0.12 ppm/0.25 ppm/0.2 ppm/0.38 ppm (MPN K-2513). Key specifications — Includes: 25 mL Sample Cup; Range: 0 to 5 ppm; Sensitivity: 0.25 ppm; Test Parameters: Total Chlorine.
CHEMETRICS Water Quality Test Kit: Iron, 10 to 100 ppm, 10 ppm, 30 Tests (MPN K-6220D). Key specifications — Includes: Flat Comparator; Range: 10 to 100 ppm; Sensitivity: 10 ppm; Test Parameters: Iron.
CHEMETRICS
CHEMETRICS Water Quality Test Kit: Iron, 10 to 100 ppm, 10 ppm, 30 Tests (MPN K-6220D). Key specifications — Includes: Flat Comparator; Range: 10 to 100 ppm; Sensitivity: 10 ppm; Test Parameters: Iron.