TG safety aquastat with manual internal adjustment and 1000 mm capillary for heating system temperature control. Operating range 40–60 °C with 20±5 °C differential, 16 A 250V~ contacts. Fits boiler and water heating…

SKU 3G-CBM-06932

Also listed as: THG 70005 · THG-70005

Brand
TG
Item
Safety aquastat internal adjustment manual operation 40-60°C capillary 1m
Category
Thermostats
UNSPSC
39122229 — Temperature switch
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

TG
tolerance
+0 −6 °C
capillary length
1000 mm
insulation grade
II
temperature range
40–60 °C
contacts rating C1
16(4)A 250V~
max head temperature
120 °C
rated impulsive voltage
2.5 kV
differential manual reset
20±5 °C
sensing element max temperature
80 °C

Datasheet Content

Caratteristiche tecniche / Technical characteristics Campo di regolazione Temperature range 40 = 60 °C Tolleranza / tolerance +0 -6 °C Differenziale (riarmo manuale)/differentiol (manual reset) 2045 ‘°C Temperatura max. di sopportazione dell’elemento sensibile 80 °C Sensing element max. temperature resistance Portata nominale dei contatti C1 16 (4)A 250V ~ Contacts rating C2 contact service Tensione impulsiva nominale / Rated impulsive voltage 2,5 kV Classe di isolamento / Insulation grade ii Temperatura max della testa / Max. head temperature T 120°C Minima temperatura di funzionamento Minimum working room temperature 0o°C Elemento sensibile a dilatazione di liquido Liquid filled sensing element Bulbo rame —- Capillare rame ricoperto PVC R3 Copper capillary and bulb — capillary protection with PVC R3 Grado di protezione / Degree of protection IPOO Termostato elettromeccanico incorporato Incorporated electromechanical thermostat 961.60328.01A Metodo di montaggio : fissaggio a vite / Mounting : screw fixing DATA Messo o terra tramite foston / earthing connection by tab terminal Ti i azi Ty f acti 2B 4A 1000 £50 ~73"Cu" ipo di azione/ ype of action _ : —— => —~ — Situazione di inquinamento del dispositivo di comando 2 _ _ Pollution level of the control device 1 Utilizzore conduttori resistenti al calore almeno T 130°C 7 To apply heat resistant conductors of minimum t Certificazioni _ _ m | Approvels ENEC 03 — CE 0497 (PED) - DIN N | = 3343 = _<€ Accessori Tappo in materiale plastico nero / Black plastic cap a ~_§_ Accessories | Dado M10x1 esagono ch. 13 / M10x1 nut hexagon key 13 u He 2 $F) ! NN yy), ‘a 8 tio fori_M4 SCHEMA ELETTRICO 1 |14/10/02] AGGIORNATO TABELLA . . holes M4 Wiring diagram REV. DATA DESCRIZIONE MODIFICHE DISEGNATO | APPROVATO i) DESCRIZIONE ‘SCALA C LIMITATORE SIC. POS. RIARMO MAN. a EH) LIMITER WITH POS. SAFETY — MANUAL RESET PRODOTTO CUENTE DISEGNATO DATA TG400 COD.SPE. ZR. [23/11/94 SOSTITUISCE IL STATO PESO GREZZO APPROWRTO ey 11 /94 [00 SNe WOE or TOLLE ‘SOSTITUITO DA TRATTAMENTO TERMICO E70 SUPERFICIALE co) DATA 1 2 c M.F 23/11/94 CODICE SEMILAVORATO T&G SPA Via T. Edison, 2 - 20040 BURAGO M. MILANO |/DISEGNO N. 4 prgusele, ouagro, © 3 propriate dso T&G SPA « non pul epvere prado n_nesaun CODICE MATERIA PRIMA Te cromra, ervey of < 961 60 328.0 1 A

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

TG Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

TG safety aquastat with manual internal adjustment and 1000 mm capillary for heating system temperature control. Operating range 40–60 °C with 20±5 °C differential, 16 A 250V~ contacts. Fits boiler and water heating applications requiring reliable overheat protection.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the TG THG70005 safety aquastat in the Philippines?

3G Electric Philippines supplies the TG THG70005 safety aquastat with delivery to Manila and Quezon City. We handle all Bureau of Customs documentation and provide PHP invoicing. Lead time on request — contact our team for availability and pricing.

What is the lead time and shipping for the TG THG70005 to the Philippines?

Lead time varies based on current availability. 3G Electric manages full logistics to your location in the Philippines, including customs clearance and documentation. Request a quote for delivery timeline and freight costs.

What temperature range and capillary length does the TG THG70005 operate at?

The TG THG70005 operates at 40–60°C with a 1000 mm capillary sensor and 20±5°C differential. It features 16A 250V~ contacts and is rated for boiler and water heating applications up to 120°C maximum head temperature.

Used in

Common applications for TG
Boiler safety limit control — TG safety aquastat (THG70002) with manual reset and fixed 110°C calibration for overheat shutdown in commercial/industrial steam systems
Hydronic heating-system temperature regulation — TG sealed aquastat (THG60010, IP55) with adjustable 0–60°C range and internal adjustment for closed-loop hot-water circuits
Chiller or cooling-loop setpoint control — TG thermostat with external adjustment (THG60008, 0–40°C) for maintaining process or comfort cooling within narrow differentials
Boiler outlet or tank temperature monitoring — TG rectangular thermometer (THG80005, 0–120°C, 3 m capillary) for visual verification of system temperature without electrical integration
Condensate or fluid-level aquastat — TG aquastat with internal adjustment (THG45008, 70–110°C, 1.5 m capillary) for heating-system protection and pump staging in district or building heating plants

TG Products

3G Electric supplies TG thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Safety aquastat internal adjustment manual reset 90-110°C capillary 3m
TG
Safety aquastat internal adjustment manual reset 90-110°C capillary 3m
Safety aquastat adj.int.man.70-90°C capillary 1.5m
TG
Safety aquastat adj.int.man.70-90°C capillary 1.5m
Aquastat internal adjustment 0-90°C capillary 1.5m
TG
Aquastat internal adjustment 0-90°C capillary 1.5m
Safety aquastat fixed manual reset 110°C capillary 1.5m
TG
Safety aquastat fixed manual reset 110°C capillary 1.5m
Aquastat capillary housing 1m50 internal adjustment 70-110°C manual reset
TG
Aquastat capillary housing 1m50 internal adjustment 70-110°C manual reset
Double immersion aquastat external adjustment 0-60°C safety 100°C
TG
Double immersion aquastat external adjustment 0-60°C safety 100°C

More from TG

View all TG parts
Double immersion aquastat ext.adj.30-120°C-ext.adj.0-60°C
TG
Double immersion aquastat ext.adj.30-120°C-ext.adj.0-60°C
Security aquastat adjustable int. gold manual actuation 90-110°C capillary 1.5m
TG
Security aquastat adjustable int. gold manual actuation 90-110°C capillary 1.5m
TG
TG
Double immersion aquastat external adj.0-90°C - external adj.30-120°C
TG
TG
Bumper
TG
TG
Square thermometer 0/120°C L1500
TG
TG
Round thermometer 0/120° D57 capillary 1 m
Aquastat capillary case 1m50 external adjustment -35/+35°C
TG
Aquastat capillary case 1m50 external adjustment -35/+35°C
Airstat 9N2.X03 80/120°C
TG
Airstat 9N2.X03 80/120°C