We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Brahma Actuator LKS 160.36 - Servo Motors
BrahmaServo Motors

Brahma Actuator LKS 160.36

Brahma LKS 160.36 is a servo motor actuator for HVAC and industrial control applications, featuring 0-90° adjustment range and IP 44 protection. Operating on 220 V 50 Hz single phase with 4 VA power consumption, it…

SKU 3G-CBM-06545

Also listed as: SER 05002 · SER-05002

Brand
Brahma
Item
Actuator LKS 160.36
Category
Servo Motors
UNSPSC
26101205 — Servo motor DC
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Brahma
voltage
220 V 50 Hz single phase
adjustment range
0-90°
protection class
IP 44
output shaft flat
7 mm
power consumption
4 VA
operating temperature
-10 to +60°C
output shaft diameter
8 mm

Datasheet Content

ACTUATOR LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS PRODUCT HANDBOOK APPLICATION The LKS 160 air damper actuator is designed to be fitted to multi-stage or modulating oil and gas burners with fully closed position. CONTENTS GENERAL Description ................................................................. 2 Features ...................................................................... 2 TECHNICAL DATA Specification ............................................................... 3 Dimensional drawings ................................................ 5 INSTALLATION AND OPERATION Installation and final checkout .................................... 6 Citrcuit diagrams ........................................................ 7 VARIOUS Standards and approvals ........................................... 9 Ordering information .................................................. 9 Accessories ................................................................ 9 1 EN2C-0112SZ20 R0202 GENERAL DESCRIPTION A synchronous motor powers a drive shaft and a backlash- can be adjusted steplessly within the operating range using free cam shaft via a gear reducer. the associated cam disc. Manually adjustable lever-operated cams or spindle-driven cams, which can be adjusted with a The cam shaft operates limit and auxiliary switches. The screwdriver, are available. position at which one of the limit or auxiliary switches operates FEATURES Electric actuator up to 3.0 Nm • Position indicator • Drive times: 3 ... 65 sec. • Easily adjustable limit and auxiliary switches • Variants: - clockwise or counter clockwise rotation • Synchronous motor - with integrated electronic circuitry - shaft version EN2C-0112SZ20 R0202 2 TECHNICAL DATA SPECIFICATION Type overview 1) clockwise rotation Diagram Shaft Drive Load torque Holding Voltage Type Remarks 2) 3) time 5) torque 6) 7) 4) Nr. Nr. s Nm Nm V S1 5 5 2,5 0,8 230 LKS 160-01 A 5-5 S1 standard version S2 5 5 2,5 0,8 230 LKS 160-03 A 5-5 S2 standard version S1 5 12 3 1,5 230 LKS 160-07 A 5-12 S1 S1 5 5 2,5 0,8 230 LKS 160-09 A 5-5 S1 Spindle-driven cam S7 5 30 3 3 24 LKS 160-22 A 5-30 S7 S7.1 5 30 3 3 110 LKS 160-24 A 5-30 S7.1 S6 5 34 3 3 230 LKS 160-25 A 5-34 S6 S1.2 5 34 3 3 230 LKS 160-26 A 5-34 S1.2 S1 5 12 3 1,5 230 LKS 160-37 A 5-12 S1 S4 5 5 2,5 0,8 230 LKS 160-39 A 5-5 S4 S2 5 3 1,5 0,6 230 LKS 160-40 A 5-3 S2 S13 5 45 3 3 230 LKS 160-42 A 6-45 S13 Spindle-driven cam S8.P1.1 5 34 3 3 230 LKS 160-44 A 5-34 S8.P1.1 Potentiometer can be retrofitted S8.P2 5 30 3 3 110 LKS 160-55 A 5-30 S8.P2 Potentiometer can be retrofitted S8.P4 5 45 3 3 230 LKS 160-59 A 5-45 S8.P4 with Potentiometer, special circuit S8.P 6 34 3 3 230 LKS 160-63 A 6-34 S8.P Potentiometer can be retrofitted S8.P4.1 5 38 3 3 120 LKS 160-65 A 5-38 S8.P4.1 Run time at 60 Hz, with Potentiometer, special circuit S8.P3 5 30 3 3 24 LKS 160-67 A 5-30 S8.P3 Potentiometer can be retrofitted S8.P1.1 5 34 3 3 230 LKS 160-68 A 5-34 S8.P1.1 Potentiometer can be retrofitted, spindle-driven cam S8.P1 5 5 2,5 0,8 230 LKS 160-70 A 5-5 S8.P1 S4 5 3 1,5 0,6 230 LKS 160-73 A 5-3 S4 S15 5 5 2,5 0,8 230 LKS 160-75 A 5-5 S15 For 3-stage operation S2 5 12 3 1,5 230 LKS 160-79 A 5-12 S2 Legend 1) when viewing from direction A (see dimensional drawing) 5) under nominal conditions 2) see “Circuit diagrams” under extreme conditions (e.g. +60 °C, 230V -15%) the torques will be 25% lower 3) see “Dimensional drawing” 6) +10% -15%; 50...60Hz 4) at 50 Hz for 90° at -15%; torque reduced by approx. 20% at undervoltage at 60 Hz, Drive times are about 20 % shorter 7) Standard: Lever-operated cam 3 EN2C-0112SZ20 R0202 1) counter-clockwise rotation Diagram Shaft Drive Load torque Holding Voltage Type Remarks 2) 3) time 5) torque 6) 7) 4) Nr. Nr. s Nm Nm V S1 5 5 2,5 0,8 230 LKS 160-02 B 5-5 S1 standard version S2 5 5 2,5 0,8 230 LKS 160-04 B 5-5 S2 standard version S1 5 3 1,5 0,6 230 LKS 160-08 B 5-3 S2 S1 5 5 2,5 0,8 230 LKS 160-10 B 5-5 S1 S2 5 3 1,5 0,6 230 LKS 160-12 B 5-3 S2 S6 5 34 3 3 230 LKS 160-18 B 5-5 S2 S2.1 5 5 2,5 0,8 230 LKS 160-19 B 5-5 S2.1 Shaft with adapter S3.2 5 5 2,5 0,8 110 LKS 160-28 B 5-5 S3.2 S4 5 5 2,5 0,8 230 LKS 160-36 B 5-5 S4 S13 6 34 3 3 230 LKS 160-43 B 6-34 S13 Spindle-driven cam S2 5 12 3 1,5 230 LKS 160-50 B 5-12 S2 S4 5 5 2,5 0,8 230 LKS 160-51 B 5-5 S4 S2 5 8 3 1,5 230 LKS 160-52 B 5-8 S2 Other cam colours S8.P1 5 12 3 1,5 230 LKS 160-57 B 5-12 S8.P1 Potentiometer can be retrofitted S4 5 12 3 1,5 230 LKS 160-60 B 5-12 S4 S6 5 5 2,5 0,8 230 LKS 160-61 B 5-5 S6 S8.P1.1 5 34 3 3 230 LKS 160-69 B 5-34 S8.P1.1 S6.1 5 5 2,5 0,8 110 LKS 160-71 B 5-5 S6.1 S4.9 5 5 2,5 0,8 230 LKS 160-74 B 5-5 S4.9 Relays control 24 VDC S6.2 5 65 3 3 230 LKS 160-76 B 5-65 S6.2 S8.P1 5 5 2,5 0,8 230 LKS 160-77 B 5-5 S8.P1 Potentiometer can be retrofitted S12 5 30 3 3 230 LKS 160-78 B 5-30 S10 Face down Legend 1) when viewing from direction A (see dimensional drawing) 5) under nominal conditions 2) see “Circuit diagrams” under extreme conditions (e.g. +60 °C, 230V -15%) the torques will be 25% lower 3) see “Dimensional drawing” 6) +10% -15%; 50...60Hz 4) at 50 Hz for 90° at -15%; torque reduced by approx. 20% at undervoltage at 60 Hz, Drive times are about 20 % shorter 7) Standard: Lever-operated cam Technical Data PCBs • for all electrical functions, increased conductor thickness Housing • impact-proof, heat-resistant synthetic material Colour: black Mains voltage Drive motor • 230 V -15% +10% or • reversible synchronous motor 110 V -15% +10% Mains frequency Switch point setting • stepless cam setting, lever-operated or spindle-driven • 50 Hz or 60 Hz cams; if spindle-driven, with superimposed scale Safety class Position indicator • II VDE 0631 • scale Power consumption Connection system • approx. 4 VA • terminal blocks Duty cicle Gearing • depending on motor, 50 to 70 % in 2 minutes • spur gearing, maintenance-free Interference suppression Drive shaft • N (according to VDE 0785) • steel Actuating angle Fitting and…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Brahma Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Brahma LKS 160.36 is a servo motor actuator for HVAC and industrial control applications, featuring 0-90° adjustment range and IP 44 protection. Operating on 220 V 50 Hz single phase with 4 VA power consumption, it suits compact automation and damper positioning systems.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy Brahma LKS 160.36 servo actuator in the Philippines?

Order the Brahma LKS 160.36 from 3G Electric Philippines. We deliver to Manila and Quezon City and handle Bureau of Customs documentation, duty processing, and logistics for you. Lead time on request.

What is the lead time and delivery for the Brahma LKS 160.36?

Lead time depends on current stock and origin availability. 3G Electric Philippines manages all shipping to Manila and Quezon City, including customs clearance and PHP invoicing. Contact us for a specific lead-time quote.

What are the power and operating specifications of the Brahma LKS 160.36 actuator?

The Brahma LKS 160.36 operates on 220 V 50 Hz single phase with 4 VA power consumption. It offers 0-90° adjustment range, IP 44 protection class, 8 mm output shaft diameter with 7 mm flat, and -10 to +60°C operating temperature range.

Used in

Common applications for Brahma
Italian light-oil burner ignition — T11 transformer as scheduled-maintenance replacement
Heavy-duty industrial burner racks — T15 / T18 / T36 for high-spark-energy applications
Combustion control-card swaps — CM31N / CM32N / CM391 onto existing Brahma-equipped burners
UV flame-detection retrofits — upgrading older photocell-based detection to solid-state UV
Safety-relay scheduled replacement — SRE / SM / FDB series on commercial gas / oil burners

Brahma Products

3G Electric supplies Brahma servo motors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Siemens
Siemens
Actuator SKP 55 001E2
Siemens
Siemens
Actuator SKP 15 001E2
Siemens
Siemens
Actuator SKP 75 501E2
Siemens
Siemens
Actuator SKP 75 001E2
Siemens
Siemens
Actuator SKP 75 003E2
Siemens
Siemens
Actuator SQM 50 481A2

More from Brahma

View all Brahma parts