Satronic Relay RMO 8853 C2 - Burner Controls
SatronicBurner Controls

Satronic Relay RMO 8853 C2

Satronic RMO 8853 C2 is a microcontroller-based burner control for single or multi-stage forced draft gas and oil burners, supporting up to 120 kW gas capacity and 30 kg/h oil throughput. Safety Class I rated with IP…

SKU 3G-CBM-06084

Also listed as: REL 60125 · REL-60125

Brand
Satronic
Item
Relay RMO 8853 C2
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Satronic
type
microcontroller-based burner control RMO88.53
application
single or multi-stage forced draft gas/oil burners
safety class
I
capacity gas max
120 kW
mounting position
optional
cable length max m
2
oil throughput max
30 kg/h
degree of protection
IP 20
power consumption va
20

Datasheet Content

7 136 ISO 9001 Burner Controls RMO88.53... RMG88.62... RMG/M88.62... Microcontroller-based burner controls for the supervision of single- or multi- stage forced draft gas / oil burners in intermittent operation. Oil throughput above 30 kg / h and a maximum capacity above 120 kW when fir- ing on gas. The RMO88.53... / RMG88.62... / RMG/M88.62... and this Data Sheet are intended for OEMs which integrate the burner controls in their products. Use, features Use The burner controls are designed for the startup and supervision of single- or multi- stage forced draft burners in intermittent operation. The RMO88.53... is for use with forced draft oil burners, the RMG88.62... / RMG/M88.62... for forced draft gas burners. When firing on oil, yellow-burning flames are supervised with photoresistive detectors QRB1B..., and blue-burning flames with blue-flame detectors QRC... When firing on gas, the flame is supervised with an ionization probe or flame detector QRA... (with ancillary unit AGQ2...A27). Firing on oil - Forced draft oil burners to EN 267 - Burner controls for use with atomization oil burners of monoblock design to EN 230 Firing on gas - Forced draft gas burners to EN 676 - Burner controls to EN 298 CC1N7136en Riello Siemens Building Technologies 11.12.2002 HVAC Products Application-specific When firing on oil features - Contact for preheating the oil - Monitoring of time for preheating the oil - Limitation of the number of repetitions When firing on gas - Monitoring of air pressure with functional check of the air pressure switch during startup and operation General - Undervoltage detection - Electrical remote reset - Accurate and reproducible program sequence owing to digital signal handling - Controlled intermittent operation after 24 hours of continuous operation - Multicolor display of status and error messages Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes should be observed! Do not open, interfere with or modify the unit! · Before performing any wiring changes in the connection area, completely isolate the burner control from the mains supply (all-polar disconnection) · Ensure protection against electric shock hazard by providing adequate protection for the burner control’s terminals · Check to ensure that wiring is in an orderly state and that the wires are firmly con- nected · Press the lockout reset button of the burner control or the reset button extension AGK20.43 only manually (applying a force of no more than 10 N), without using any tools or pointed objects · Fall or shock can adversely affect the safety functions. Such units may not be put into operation, even if they do not exhibit any damage Engineering notes · When used in connection with actuators, there is no position feedback signal from the actuator to the burner control · The running times of the actuators must match the burner control’s program. An additional safety check of the burner control together with the actuators is required Mounting notes · Ensure that the relevant national safety regulation are complied with 2/21 Siemens Building Technologies CC1N7136en HVAC Products Riello 11.12.2002 Installation notes · Installation work must be carried out by qualified staff · Observe the permissible lengths of the detector cables (refer to «Technical data») · Always run the high-voltage ignition cables separately while observing the greatest possible distances to the unit and to other cables · Install switches, fuses, earthing, etc., in compliance with local regulations · Ensure that the maximum permissible current ratings will not be exceeded (refer to «Technical data») · Do not feed external mains voltage to the control outputs of the unit. When testing the devices controlled by the burner control (fuel valves, etc.), the burner control must never be connected · Phase and neutral conductors may not be interchanged Electrical connection of ionization probe and flame detector It is important to achieve practically disturbance- and loss-free signal transmission: · The cable length must not exceed 1 m · Never run the detector cable together with other cables – Line capacitance reduces the magnitude of the flame signal – Use a separate cable · Insulation resistance – Must be a minimum of 50 MW between ionization probe and ground – Soiled detector holders reduce the insulation resistance, thus supporting creep age currents · Earth the burner in compliance with the relevant regulations; earthing the boiler alone does not suffice Only when firing on gas · Observe the polarity With supervision of the ionization current, the burner controls can detect wrong polarity of live and neutral conductors, in which case they initiate lockout at the end of «TSA» · The ionization probe must be protected against electric shock hazard · Locate the ionization probe such that – the ignition spark cannot arc over to the ionization probe (risk of electrical overloads) – the ignition spark cannot adversely affect supervision of the ionization current · In networks with nonearthed neutral conductor and ionization current supervision, terminal 6 must be connected to burner ground 3/21 Siemens Building Technologies CC1N7136en HVAC Products Riello 11.12.2002 Commissioning notes · Commissioning work must be carried out by qualified staff · When commissioning the plant or when doing maintenance work, make the follow- ing safety checks: Safety check Anticipated response a) Burner startup with flame detector darkened or Lockout at the end of «TSA» with open-circuit to the ionization probe b) Burner startup with flame detector exposed to Lockout after no more than extraneous light (only when firing on oil) 25 seconds or immediate lockout during the prepurge time c) Burner operation with simulated flame failure; for Firing on oil: Repetition followed that purpose, darken the flame detector during by lockout at the end of «TSA» operation and maintain that status or interrupt Firing on gas: immediate lockout the gas supply after the flame has extinguished d) Burner startup with response from air pressure Lockout at the end of the waiting switch (only when firing on gas) time «tw» e) Burner operation with simulated loss of air pres- Immediate lockout sure (only when firing on gas) Standards Conformity to EEC directives - Electromagnetic compatibility EMC (immunity) 89 / 336 EEC - Directive for gas-fired appliances 90 / 396 EEC - Low-voltage directive 73 / 23 EEC Service notes · Maintenance work must be carried out by qualified staff · Each time a unit has been replaced, check to ensure that wiring is in an orderly state and that the wires are firmly connected. Make the safety checks as listed in «Commissioning notes» Disposal notes The unit contains electrical and electronic components and may not be disposed of together with household waste. Local and currently valid legislation must be observed. Mechanical design The housing of the burner controls is made of impact-proof, heat-resistant and flame- retarding plastic. The housing accommodates the - microcontroller which controls the program sequence, and the relays for load con- trol - electronic…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Satronic Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Satronic RMO 8853 C2 is a microcontroller-based burner control for single or multi-stage forced draft gas and oil burners, supporting up to 120 kW gas capacity and 30 kg/h oil throughput. Safety Class I rated with IP 20 protection, it integrates into industrial heating and combustion systems.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy a Satronic RMO 8853 C2 burner control in the Philippines?

3G Electric Philippines is an authorized distributor of Satronic RMO 8853 C2 relay controls. We offer delivery to Manila and Quezon City with full logistics and Bureau of Customs documentation support. Request a quote via our website or contact our team for pricing and lead time.

What is the lead time for the Satronic RMO 8853 C2?

Lead time varies based on stock availability and delivery route to your location. Typical lead times range from 2–4 weeks for standard orders. 3G Electric handles all import clearance and customs processing to the Philippines. Contact us for a confirmed delivery schedule.

What is the maximum capacity of the Satronic RMO 8853 C2 burner control?

The RMO 8853 C2 supports up to 120 kW for gas burners and 30 kg/h oil throughput. It is rated Safety Class I with IP 20 protection and suits single or multi-stage forced draft gas and oil burners in industrial heating applications.

Used in

Common applications for Satronic
Steam boiler systems — Satronic MZ770S photocell and ZT870 transformer for flame detection and ignition control.
Industrial gas furnaces — Satronic IRD820 infrared photocell and control modules for continuous flame supervision during high-temperature processes.
Oil and gas burner retrofit — Satronic replacement photocell connectors and transformers for upgrading legacy burner safety systems.
Commercial heating equipment — Satronic burner control assemblies in air heaters and unit heaters for building HVAC systems.
Process heater automation — Satronic flame-fail relays and photocell harnesses in thermal-oil and hot-water heating loops.
Preventive maintenance programs — Satronic spare-parts kits stocked for scheduled photocell and transformer replacement in high-availability industrial facilities.

Satronic Products

3G Electric supplies Satronic burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Satronic
Satronic
Relay RMG508
Relay 553 SE
Satronic
Relay 553 SE
Relay 552 SE
Satronic
Relay 552 SE
Relay CMG 8862 D2 (replaces RMG8862C2)
Satronic
Relay CMG 8862 D2 (replaces RMG8862C2)
Satronic
Satronic
Relay 503 SE
Relay 550 SE
Satronic
Relay 550 SE

More from Satronic

View all Satronic parts
Satronic
Satronic
Relay CM 391-2 Frisquet
High sensitivity UV bulb
Satronic
High sensitivity UV bulb
Satronic
Satronic
IRD 1020 cell axial blue (oil and gas)
Satronic
Satronic
Relay DMG 970-N MOD.03
Satronic
Satronic
Relay SM 592.2 TW1.5/TS5
Satronic
Satronic
Relay CM 381N.4 TW5/TS5
Satronic
Satronic
Relay MG569-BWZG (replaces 568 SE)
Satronic
Satronic
Relay TF 836.3