Satronic CE 11 TW20/TS10 relay

The Satronic CE 11 TW20/TS10 is a relay for automatic gas burner control in atmospheric and fan-assisted burners, operating at 230V 50/60Hz with intermittent duty. It features volatile lock-out safety and 1.2 µA…

SKU 3G-CBM-06048

Also listed as: REL 45171 · REL-45171

Brand
Satronic
Item
CE 11 TW20/TS10 relay
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Satronic
operation
intermittent
application
automatic gas burner control
burner type
atmospheric and fan assisted
safety feature
volatile lock-out
supply voltage
230V 50/60Hz
minimum ionization current
1.2 µA

Datasheet Content

EUROBOX SERIES TYPES CE... SE... ME... Application AUTOMATIC GAS BURNER CONTROL This range of electronic gas burner control systems has SYSTEMS FOR GAS BURNERS AND GAS been designed specifically for atmospheric and fan assistec BURNING APPLIANCES WITH OR burners for intermittent operation (systems for non­ WITHOUT FAN permanent operation ). Ali these controls are provided with volatile lock-out, which means that a restart from the safety shut-down condition can only be accomplished by an interruption of the main power and its subsequent restoration. The automatic burner control units of this series are suitabh for: -combi boilers -heating boilers -warm air generators -radiant heaters -water heaters Due to the design and the variety of models they can be used aise for the automation of ovens, cockers and in general in gas firing installations with atmospheric burner. Features Table 1 shows the main featùres of.this series. Other important features are: - EC - Type certification (CE Reg. N ° 63AQ0625) in accordance with Gas Appliance Directives 90/396 and 93/68; - in accordance with EN298 (European standard for automatic gas burner control systems); - flame monitoring by the rectification property of the flame: ionization; - electrical service lite at max. loading >250.000 operations; - inbuilt ignition device coinpletely of solid state design and high efficiency; - auxiliary contact for low power ignition or main gas valvt control for intermittent pilot systems (this contact is not o isolated from the main supply voltage by reinfrced isolati�n. therefore the relay contact -is not suitable to supply SELV circuits-� Safety Extra Low Voltage, e.g. 24V); - different connections and fixings: --- --.____. TABLE ï BURNER -- -- ~ N O ~ ~ P 3 3 â v m O W U U ~ ~ ~ w e O Q m 0 z z O ~y O E L L 2., ~ g ~ ~ m a ô ô _° m E ~ ô ~ ~ ~ j m ~ U ~ ~ ~ ô o g m ~ o CE 19i AMCVXN SE 191 - - -- - k -- - AMCVXN SE 192 R AMCVXN CE 391 FMCVXN SE 152 AMCVXN SE 592 AMCVXN ME 197 ' AMCVXN ME 192 * * AMCVXN NOTE: (1):This contact is not isolated from main supply voltage by reinforced isolation, therefore the relay contact is not suitable to supply SELV circuits - Safety Extra Low Voltage, e.g, 24V. (2): Flame failure during TS causes spark restoration TECHNICAL DATA -Minimum ionization current: 1.2~.~A Supply Voltage: 230V-50/60Hz on request: 0.5~eA on request: 110/120V-50/60Hz -Recommended ionization curent: 3 + 5 times the Operating temperature singe: -20°C +60°C minimum ionization current Amblent humidity: 95% max at 40°C -Max. length of the table: 1 m Protection degree: -Minimum insulation resistance of table and flame deteclor socket NG: IP 40 (alter installation) device to Barth: a 50MS2 socket P/R IP 00 -Max. parasitic capacitance of Times: detection probe: s 1 nF -Prepurge or waiting time (TV1n: 1,5/3/5/10/20/30/40 s -Max. short circuit current: < 200E~A AC -Safety time (TS): 3/5/8/10/20/30/40/50/60 s Ignition: -Drop out time on running flame failure: <1s -Ignition voltage: 8 KV at 30pF loading The times given on the burner control label correspond to -Repetition rate: 25 Hz the values guaranteed. The actual values differ slightly from -Max.length of the table: 2m the values given, pre-purge and waiting times are in fact -Spark gap recommended: 2-4 mm longer and safety time shorter than their nominal values. -Consumption: 2,5 VA Power consumption,at starting up: -Spark energy: 15 mJ atmospheric burner 10 VA Weight: atmospheric fan-assisted burner 12 VA -with socket P or R: 220 g Power consumption, running: -with socket NG: 275 g atmospheric humer 7 VA Controls for special applications: atmospheric fan~assisted humer 9 VA On request it is possible to meet special requirements Contact rating: I max concerning times, repetition rate of the sparks, minimum -Thermostat: 4 A cos ~ = 0.4 ionization current and operating cyGe. -EV1: 0.5 A cos ~ = 0.4 CONSTRUCTION -EV2: 0.5 A cos ~ = 0.4 The enclosure made of plastic material protects the control -EVG: 0.5 A cos ~ = 0.4 ftom mechanical damage, dust and dirt from the conditions -Fan: 1 A cos ~ = 0.4 of installation. The particular construction, consisting of four -Alarm: 0.5 A cos ~ = 1 printed circuit boards in order to forma "box" stn~cture, has -Auxiliary contact: 0.5 A cos ~ = 0.4 allowed a reduction in the volume of the control unit. -Extemal ignition: 1.5 A cos cp = 0.2 A varistor protects the control from voltage transients on the Max. length of the tables of mains supply. An intemal fuse protects the relays of the externat components: 1 m control bax in case of short circuits on the outputs (valves, Fuse rating internat: 4 A Fast fan and lock-out signa. This is not an accessible fuse and Fuse rating extemal: 3.15 A Fast the control must be protected with a fuse of the fast blow Flame control: type.suitable to the load connected and never exceeding The ionization flame detector device makes use of the 3.15A. rectification property of the flame. Overall Dimensions The ionization flame detector device is not a safe to touch The control units of the EUROBOX sertes tan be suppliE output(no provision with protective impedances). with different executions of the enclosure depending on the fixing system required. Enclosures can be proa+'sd~d with or without fixing brackets on the sides. Please noie that the control unifs with fixing ~ . ~ brackets on the sides can only fit connec4ing sockets type P or R, as these are provided with suitable hooks. __"— asa In the part reference the suffix describes the exécution of 423 62.7 —~ the enclosure: 3 with fixing brackets III II III ICI ~I III III III III III…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Satronic Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Satronic CE 11 TW20/TS10 is a relay for automatic gas burner control in atmospheric and fan-assisted burners, operating at 230V 50/60Hz with intermittent duty. It features volatile lock-out safety and 1.2 µA minimum ionization current, serving as the control foundation for standard burner applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy the Satronic CE 11 TW20/TS10 relay in the Philippines?

3G Electric Philippines supplies the Satronic CE 11 TW20/TS10 relay with delivery to Manila, Quezon City, and CALABARZON industrial zones. We handle Bureau of Customs documentation, import logistics, and PHP invoicing for seamless procurement.

What is the lead time for the Satronic CE 11 TW20/TS10 relay?

Lead time depends on current stock and sourcing availability. Contact 3G Electric Philippines for a specific delivery timeline. We manage all international logistics and customs clearance to ensure timely arrival at your facility.

What burner types does the Satronic CE 11 TW20/TS10 relay control?

The CE 11 TW20/TS10 controls automatic gas burners in atmospheric and fan-assisted applications. It operates at 230V 50/60Hz intermittent duty with 1.2 µA minimum ionization current and volatile lock-out safety for standard industrial burner installations.

Used in

Common applications for Satronic
Steam boiler systems — Satronic MZ770S photocell and ZT870 transformer for flame detection and ignition control.
Industrial gas furnaces — Satronic IRD820 infrared photocell and control modules for continuous flame supervision during high-temperature processes.
Oil and gas burner retrofit — Satronic replacement photocell connectors and transformers for upgrading legacy burner safety systems.
Commercial heating equipment — Satronic burner control assemblies in air heaters and unit heaters for building HVAC systems.
Process heater automation — Satronic flame-fail relays and photocell harnesses in thermal-oil and hot-water heating loops.
Preventive maintenance programs — Satronic spare-parts kits stocked for scheduled photocell and transformer replacement in high-availability industrial facilities.

Satronic Products

3G Electric supplies Satronic burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Satronic
Satronic
Relay CM 32 TW20/TS10
Satronic
Satronic
CM391 TW1.5/TS10 relay
Satronic
Satronic
Relay SM 592.2 TW1.5/TS10
Satronic
Satronic
Relay SM 592.2 TW5/TS10
Satronic
Satronic
SM 11F relay
Relay TM 31 TW1,5/TS10
Satronic
Relay TM 31 TW1,5/TS10

More from Satronic

View all Satronic parts
Satronic
Satronic
Relay CM 391-2 Frisquet
High sensitivity UV bulb
Satronic
High sensitivity UV bulb
Satronic
Satronic
IRD 1020 cell axial blue (oil and gas)
Relay RMO 8853 C2
Satronic
Relay RMO 8853 C2
Satronic
Satronic
Relay DMG 970-N MOD.03
Satronic
Satronic
Relay SM 592.2 TW1.5/TS5
Satronic
Satronic
Relay CM 381N.4 TW5/TS5
Satronic
Satronic
Relay MG569-BWZG (replaces 568 SE)