We ship to the Philippines — door-to-door, customs and logistics handled by 3G Electric

Image not available
SatronicBurner Controls

Satronic RE3 ionization relay

The Satronic RE3 is an ionization flame detector for gas burners featuring a sub-1 second reaction time and 600 mm cable length. It provides 5A 250V AC contact rating and operates with minimum ionization current of…

SKU 3G-CBM-06012

Also listed as: REL 45132 · REL-45132

Brand
Satronic
Item
RE3 ionization relay
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — the Philippines

Delivery
5–8 business days door-to-door; Bureau of Customs clearance typically 2–4 business days.
Payment
Invoicing in PHP or USD. Bank transfer and corporate PO accepted.
Ships to
Manila, Quezon City, Cebu, Davao, Batangas

Technical Specifications

Satronic
type
flame detector for gas burners
model
RE3
standard
EN 60730
cable length
600 mm
external fuse
50 mA T
reaction time
<1 s
contact rating
5A 250V AC (cosφ=1.0), 3A 250V AC (cosφ=0.4), 5A 30V DC
power consumption
3 VA
minimum ionization current
0.5 µA
recommended ionization current uv
>15 µA
recommended ionization current electrode
>5 µA

Datasheet Content

FLAME DETECTOR FOR GAS TYPE RE3 DESCRIPTION The RE3 control is suitable to verify the presence of flame on gas burners. In fact it can use either a UV phototube or an electrode to exploit the flame rectification effect (ionization). FEATURES − in accordance with EN 60730; − electrical service life at max. declared loading > 250.000 operations; − compact and easy installation; − connecting socket with screws or fast-on terminals (types A, B, N and T); − signalization with LEDs of different colour: green (POWER) and red (FLAME). MAIN APPLICATIONS The RE3 flame detector is mainly used for industrial applications and for the installation of semiautomatic ignition and control systems, when it is necessary to control simultaneously and sequentially several burners. The presence of LEDs to signalise the operation also permits the use of RE3 control simply as flame detector. OPERATION Supply is signalled by the turning on of the green coloured LED (POWER) fitted on the front of the plastic enclosure. A second LED, red coloured, placed next to the first one, turns on when the flame detection has occurred. This event corresponds to the switching on of the independent contacts available in output. 4071_r06 1/4 OVERALL DIMENSIONS Fig.2 Fig.3 Socket A B (code 18210130) Socket T As regards the phototube life, we suggest to replace it after 10.000 hours to avoid the danger of a “flame on” signal also after the flame has been extinguished, which is likely to happen when the tube gets too old. DETECTION ELECTRODE The detection electrode we produce can be supplied in different shapes and dimensions (see Fig.4). Socket N (18210095) Fig.1 This control can use the connecting sockets with screw terminals mod. A B, N or socket mod. T. for fast - on Fig.4 terminals, which couples with lateral bolted enclosure. TECHNICAL DATA ACCESSORIES - Supply: 220-230V-50/60Hz The users’ different requirements regarding flame detection on request: 240V-50/60Hz for gas systems, can be met by using the following probes 110-120V-50/60Hz of our production: - Operating temperature: 0 ÷ 60°C - Humidity: 95% max. at 40°C - UV1 standard phototube (Fig.2); - Case Protection Degree: IP40 - UV1/H high sensitivity phototube: - Power consumption in running: 3 VA Case: nylon - Contact rating: 5A 250 V AC ( cosϕ = 1.0) Case diameter: mm 22 3A 250 V AC ( cosϕ = 0.4) Case length: mm 85 5A 30 V DC Cable length: mm 600 (standard) - External Fuse (F): 50 mA T - UV2/N (Fig.3): - Minimum ionization current: 0,5µA Case: nylon - Recommended ionization current: Case diameter: mm 17 with UV tube: > 15µA Case length: mm 76 with electrode: > 5µA Cable length: mm 600 (standard) - Reaction time: < 1s Weight: with AB socket 280 g with B socket 300 g with T socket 250 g with N socket 290 g 2/4 4071_r06 CONSTRUCTION The plastic material made enclosure protects the control from possible damages depending on crashes, openings, dust deposit, contact with outside ambient. Two LEDs of different colour, GREEN for power on and RED for flame on, fitted on the upper side of the enclosure, permit an immediate identification of the state of burner and control; a version without signalling LEDs is also available. DIRECTIONS FOR INSTALLATION DETECTION − Connect and disconnect the control only with supply off. PROBE − The control can be assembled in every position. − Avoid exposure to dripping water. − Ventilation with the lowest temperature ensures the longest life of the control. − Make sure that you are using the correct type and code before installing or replacing the control. ELECTRICAL INSTALLATION Fig.6 − Every contact must be protected with a fuse of the fast Fig.7 shows the diagram suitable to the installation of a blow type suitable to the loads connected; semiautomatic system for gas burners. For the flame − Before starting the control, check cables and detection, both an ionization electrode or a phototube can connections carefully (see Fig.5). Wrong be used. connections can damage the control and Acting on the manual start button PM (with two contacts compromise the safety of the application; normally open) supply is given to the TR ignition − Avoid placing the detection cable close to power or transformer and the EV 1 gas valve; the manual pressure ignition cables; on the button must be kept until the flame is built and − Use a detection cable as short as possible (max. stable. recommended length <5m); − A suitable degree of protection must be guaranteed; APPLICATION EXAMPLES − The relevant electrical safety standards must be respected. NOTE1 NC COM NA NA COM NC BLUE 5A 5A UV BRAHMA TYPE RE3 MADE IN ITALY NOTE1: WIRE MARKED WITH NUMBER 8 Fig.7 DET. PROBE NC COM NA NA COM NC By releasing the button PM, the ignition transformer is turned off and the operation continues until one of the following situations occurs: - action on the manual stop button PA; - intervention of the thermostat T; - flame failure. In any situation, the operation can be reset only by manual 5A 5A intervention on start button PM. In the same picture is also represented a duty example of the second available contact, to detect the flame in BRAHMA TYPE RE3 MADE IN ITALY distance. Fig.8 represents two connection diagrams for using the Fig.5 RE3 flame detector with the control box for automatic gas CHECKING AT START burners, model CM391 belonging to the EUROBOX series Always check the control before the first start and also after (see the relevant leaflet). a long period of system off. Before any ignition attempt make sure that the combustion chamber is free from gas. Then check that the level of the flame signal is sufficient (see Fig.6a and 6b for the measuring). 4071_r06 3/4 BURNER 1 BURNER 2 LIVE NEUTRAL (a) LIVE NEUTRAL (b) Fig.8 The diagram in Fig.8a differs from the one in Fig.8b for the presence of fan control and air pressure switch. This connection permits the ignition of two burners in sequence, with cross checking of the “flame on” state. A contact of the internal relay of RE3 is used to check the efficiency of the detector to prevent the beginning of the ignition cycle if the NOTES ABOUT PRODUCT DISPOSAL The device detector doesn’t operate correctly. contains electronic components and cannot therefore be The ignition of burner 2 occurs only after the ignition of disposed of as normal household waste. For the disposal burner 1 and, as the flame detection is cross - checked procedure, please…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Satronic Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Satronic RE3 is an ionization flame detector for gas burners featuring a sub-1 second reaction time and 600 mm cable length. It provides 5A 250V AC contact rating and operates with minimum ionization current of 0.5 µA, meeting EN 60730 standards for burner control applications.

Supplied to the Philippines — compatible with 60 Hz installations. DHL Express delivery to Manila, Quezon City, Cebu, customs and duties handled door-to-door.

Frequently Asked Questions

Where can I buy a Satronic RE3 ionization relay in the Philippines?

Order from 3G Electric Philippines. We supply the Satronic RE3 with delivery to Manila, Quezon City, and provinces via logistics handled in-house. Bureau of Customs documentation and PHP invoicing included. Lead time on request.

What is the reaction time and cable length of the Satronic RE3?

The RE3 delivers sub-1 second (<1 s) reaction time for rapid flame detection. Cable length is 600 mm. It meets EN 60730 burner control standards with minimum ionization current 0.5 µA.

What are the electrical contact ratings for the RE3 ionization relay?

Contact rating is 5A 250V AC (cosφ=1.0), 3A 250V AC (cosφ=0.4), or 5A 30V DC. External fuse is 50 mA T. Power consumption is 3 VA. Recommended ionization current is >15 µA at UV and >5 µA at electrode.

Used in

Common applications for Satronic
Steam boiler systems — Satronic MZ770S photocell and ZT870 transformer for flame detection and ignition control.
Industrial gas furnaces — Satronic IRD820 infrared photocell and control modules for continuous flame supervision during high-temperature processes.
Oil and gas burner retrofit — Satronic replacement photocell connectors and transformers for upgrading legacy burner safety systems.
Commercial heating equipment — Satronic burner control assemblies in air heaters and unit heaters for building HVAC systems.
Process heater automation — Satronic flame-fail relays and photocell harnesses in thermal-oil and hot-water heating loops.
Preventive maintenance programs — Satronic spare-parts kits stocked for scheduled photocell and transformer replacement in high-availability industrial facilities.

Satronic Products

3G Electric supplies Satronic burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Satronic
Satronic
SM 11F relay
Satronic
Satronic
Relay SR3/TR2V SF
Satronic
Satronic
Relay SM 152.2
Satronic
Satronic
Relay SM 191.2
Satronic
Satronic
Relay CM391.2 10.5
Satronic
Satronic
Relay CM 12U

More from Satronic

View all Satronic parts
Satronic
Satronic
Relay CM 391-2 Frisquet
High sensitivity UV bulb
Satronic
High sensitivity UV bulb
Satronic
Satronic
IRD 1020 cell axial blue (oil and gas)
Relay RMO 8853 C2
Satronic
Relay RMO 8853 C2
Satronic
Satronic
Relay DMG 970-N MOD.03
Satronic
Satronic
Relay SM 592.2 TW1.5/TS5
Satronic
Satronic
Relay CM 381N.4 TW5/TS5
Satronic
Satronic
Relay MG569-BWZG (replaces 568 SE)